USA flag logo/image

An Official Website of the United States Government

RF Interface System and Coil for Multi-Nuclear Lung MR Imaging at 3T

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
96330
Program Year/Program:
2010 / SBIR
Agency Tracking Number:
HL102947
Solicitation Year:
N/A
Solicitation Topic Code:
NHLBI
Solicitation Number:
N/A
Small Business Information
CLINICAL MR SOLUTIONS, LLC
3735 SHADYBROOK PL BROOKFIELD, WI 53005
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2010
Title: RF Interface System and Coil for Multi-Nuclear Lung MR Imaging at 3T
Agency: HHS
Contract: 1R43HL102947-01
Award Amount: $157,589.00
 

Abstract:

DESCRIPTION (provided by applicant): Hyperpolarized helium and xenon MRI of the lungs has been shown to provide useful physiological information about pulmonary function. Hyperpolarized helium imaging has been shown to provide outstanding imaging of lung g as spaces while allowing for structure-function information such as alveolar dimensions and oxygen depletion. Hyperpolarized xenon dissolves in the blood pool through lung parenchyma, opening up the potential for simultaneous ventilation and perfusion imag ing and gas exchange measurements. Further, imaging of inert fluorinated gases such as SF6 show great promise for pulmonary imaging. While much work has been performed to characterize the utility of gas imaging, the field still remains in the research phas e, partially due to the lack of available clinical RF technology for multinuclear scanning. Here, we propose to create an RF coil and interface platform that can be permanently tuned to any of the aforementioned specific frequencies. Further, this technolo gy will be specifically created for 3T magnets, a field strength that more and more hospitals are purchasing and installing. This coil and interface design will be developed by Ralph Hashoian at Clinical MR Solutions, who has previously designed and delive red coils for gas imaging, and it will be validated and tested by Mitchell Albert at the University of Massachusetts Medical School, a co-inventor of in vivo hyperpolarized gas imaging. Our coil design will consist of a transmit/receive quadature flexible coil with four loop elements. This design will simultaneously allow for patient comfort and homogenous transmission with high signal to noise reception. Our preliminary results at 1.5T using this type of coil design in hyperpolarized helium imaging have pr oduced excellent results. The coil interface will consist of a low loss, high power transmit receive switch, low noise pre-amplifiers, and a Quadrature hybrid, all integrated into an injection molded enclosure that will plug into the main system coil conne ction. Included will be specific OEM required circuits for coil ID, fault analysis and PIN diode drivers. This integrated interface approach will allow for easier coil connections for all the gas frequencies involved in the study and ensure a simple, robus t and clinically relevant interface. Finally, our RF coil design and interface platform will be designed to overcome the challenges at 3T including high RF power deposition, increased patient impedance matching loss, and patient safety concerns. Once devel oped, we will test our design by acquiring hyperpolarized helium ventilation and airway images. These images will be evaluated by a radiologist for image quality and homogeneity. Taken together, our design will offer more clinically effective RF coils and interface to the research community and ultimately hasten the transition to the clinic. PUBLIC HEALTH RELEVANCE: Hyperpolarized gas and inert fluorinated gas MR imaging stand at the doorstep of clinical application. However, their advancement to the clinic is hindered by the lack of available multinuclear RF technology to perform these exams. Here, we propose an RF coil design and scanner interface that is seamlessly integrated into the clinical scanner to image hyperpolarized helium, xenon, or inert fluorinated gases at 3T. This design, which is targeted for clinical compliance, will allow for high signal to noise imaging while maintaining patient comfort and safety. Taken together, the proposed architecture of an integrated coil and interface will f acilitate clinical gas lung imaging and ultimately help facilitate clinical acceptance and translational research of the technique.

Principal Investigator:

Ralph Hashoian
2627819394
RALPH@CLINICALMRSOLUTIONS.COM

Business Contact:

Ralph Hashoian
ralph@clinicalmrsolutions.com
Small Business Information at Submission:

CLINICAL MR SOLUTIONS, LLC
CLINICAL MR SOLUTIONS, LLC 3735 SHADYBROOK PL BROOKFIELD, WI 53005

EIN/Tax ID: 139203764
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No