USA flag logo/image

An Official Website of the United States Government

Measuring Oxidative Stress in Animal Models of Neurodegeneration

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
96472
Program Year/Program:
2010 / SBIR
Agency Tracking Number:
NS067920
Solicitation Year:
N/A
Solicitation Topic Code:
NINDS
Solicitation Number:
N/A
Small Business Information
EKAM IMAGING, INC.
29 YORKSHIRE TER, APT 6 SHREWSBURY, MA 01545
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2010
Title: Measuring Oxidative Stress in Animal Models of Neurodegeneration
Agency: HHS
Contract: 1R43NS067920-01A1
Award Amount: $99,189.00
 

Abstract:

DESCRIPTION (provided by applicant): There is clear evidence that mitochondrial dysfunction and oxidative stress are precipitating and exacerbating factors in neurodegenerative diseases. The development and commercialization of radio frequency electron ics for use in animal models of neurodegeneration to assess oxidative stress is critical to the development of new therapeutics. This technology will be used to identify surrogate markers of disease progression that translate from animals to humans for use in the assessment of therapeutic efficacy in early clinical trials helping to improve time-to-market and save hundreds of millions of dollars in R and D costs. Ekam Imaging Inc. (Ekam) has focused this grant application on developing a 1H/31P radio freque ncy coil system for use in magnetic resonance spectroscopy to evaluate oxidative stress and mitochondrial dysfunction in animal models of neurodegeneration. In this Phase I application, Ekam will use a rodent model of Parkinson's disease (PD) to test and o ptimize coil design. The specific aims are to design and manufacture a prototype rat 1H/31P dual coil system and field test the 1H/31P dual coil system. If successful, a Phase II application will be submitted which will establish this MR spectroscopy techn ology and its application in a monkey model of PD. Engineers at Ekam will simulate the size, load and electrical properties of a biological object (in this case, an adult rat head) and model the electromagnetic behavior of a coil designed for this specific application. This data will be integrated with RF simulations to predict circuit components for board layouts that will be engineered to fit the product design. Two separate coils, one for 1H and another for 31P will be developed and made interchangeable. Thus, a rat will be imaged first with the 1H coil for high resolution anatomy and 1H spectroscopy (lactate and glutathione specifically) followed by 31P spectroscopy for (phosphate metabolism and pH). Coil simulations will be run with mechanical designs o ptimized for space filling to accommodate an adult rat head.

Principal Investigator:

Steven P. Toddes

Business Contact:

Small Business Information at Submission:

EKAM IMAGING, INC.
EKAM IMAGING, INC. 29 YORKSHIRE TER, APT 6 SHREWSBURY, MA 01545

EIN/Tax ID: 133119951
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No