USA flag logo/image

An Official Website of the United States Government

PRECISE 3D QCT TO MONITOR OSTEOPOROSIS THERAPY

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
60626
Program Year/Program:
2002 / STTR
Agency Tracking Number:
AR045713
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
IMAGE ANALYSIS, INC.
IMAGE ANALYSIS, INC. 1380 BURKESVILLE ST COLUMBIA, KY 42728
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2002
Title: PRECISE 3D QCT TO MONITOR OSTEOPOROSIS THERAPY
Agency: HHS
Contract: 2R42AR045713-02A1
Award Amount: $363,528.00
 

Abstract:

DESCRIPTION (provided by applicant):The growing number of women receiving drug treatment for osteoporosis underscores the need for sensitive methods to monitor therapy. Because it permits selective assessment of the trabecular and cortical bone, which may respond differently to disease and therapy, quantitative computed tomography (QCT) is well-suited to this purpose. However, the ability of QCT to resolve therapy- or disease-induced changes in bone mineral density (BMD) is limited by variable precision errors. These precision errors mostly relate to the operator-dependence of current techniques, which involve manual slice selection and region of interest placement. In our Phase I Grant, we have addressed this problem by developing and demonstrating the feasibility of an image registration algorithm which aligns serial images and uses the resulting 3D transformation to map a baseline region into the same volume of the follow-up image. As we have documented in the Phase I Final Report, this fast and automated approach yields precision errors in vivo of 1.0 mg/cc and 0.9 mg/cc for spinal and proximal femoral trabecular BMD measurements respectively. In this application, we propose to develop and commercialize a prototype software package which will combine diagnostic 3D QCT BMD measurements with our new approach for highly reproducible longitidunal measurements. PROPOSED COMMERCIAL APPLICATION: We will provide commercial CT imaging centers with a powerful set of tools which they can use to compete in the bone mineral density measurement market. The diagnostic measurement component will allow CT scanners to measure bone mineral density in the spine and hip in bone regions comparable to those measured by DXA. Moreover, the high reproducibility of our technique will permit CT centers to offer a method for monitoring therapy effects which will be superior to DXA.

Principal Investigator:

Thomas F. Lang
4155024698
THOMAS.LANG@OARG.UCSF.EDU

Business Contact:

Ben Arnold
4155024698
ARNOLD@IMAGE-ANALYSIS.COM
Small Business Information at Submission:

IMAGE ANALYSIS, INC.
IMAGE ANALYSIS, INC. 1380 BURKESVILLE ST COLUMBIA, KY 42728

EIN/Tax ID: 611225980
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
University of CA at San Francisco
UCSF
SAN FRANCISCO, CA 94143
RI Type: Nonprofit college or university