A Needle Guidance System for Hepatic Tumor Ablation That Fuses Real-Time…

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
93616
Program Year/Program:
2009 / SBIR
Agency Tracking Number:
CA143234
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
INNEROPTIC TECHNOLOGY, INC.
106A N. Churton St. Hillsborough, NC -
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2009
Title: A Needle Guidance System for Hepatic Tumor Ablation That Fuses Real-Time Ultrasou
Agency: HHS
Contract: 1R43CA143234-01
Award Amount: $149,728.00
 

Abstract:

DESCRIPTION (provided by applicant): This project proposes to enhance the capabilities of InnerOptic's InVision System (IVS) for needle guidance during hepatic tumor ablation procedures via an innovative and inexpensive method to warp pre-operative CT data in real time. Ablation has been demonstrated as a promising alternative to surgical resection to treat hepatic tumors, but needle placement difficulties have been reported due to poor visualization of the anatomy with currently-available technology. Con ventional ultrasound guidance is intra-operative, but some tumors are only visible in computed tomography (CT); however, CT data of soft tissue becomes obsolete as soon as the tissue moves even a small amount (e.g., from breathing). We have already develop ed the IVS technology to address this problem: with it, the positions and orientations of the ablation needle and of the intra-operative ultrasound transducer used for needle guidance are continually monitored. A stereoscopic computer-generated real-time v isualization displays dynamic avatars of needle and transducer as the physician advances the needle towards the target; in this way, the spatial relationship between needle and ultrasound slice is clear, and the surgeon can more easily target a feature in the ultrasound slice with the ablation needle. Here, we propose an improvement to this guidance system that will enhance a physician's spatial understanding even further. We introduce a novel and computationally-inexpensive means to warp pre-operative comp uted tomography (CT) data, and an updated guidance system that incorporates the real-time-deformed CT data in registration with the intra-operative ultrasound. The physician would then benefit from the complementary information provided by both the ultraso und and CT data, and could optimally plan and execute the ablation procedure. In this Phase I, we propose to develop the prototype by enhancing our existing IVS, and thus leveraging hardware and software that is already available to us. We will then verify the performance accuracy of the system, and proceed with both quantitative and qualitative testing by our surgeon consultants. We will pursue two rounds of testing: the first will provide an opportunity to optimize the ergonomic aspects of the device, and the second will yield both quantitative and qualitative performance data. The technology described here is by no means limited to ablation procedures. In the future, it could in the future be adapted to any procedure in which needles, ultrasound and pre-o perative scans such as CT or MRI are employed. PUBLIC HEALTH RELEVANCE: We propose an advanced visualization system for ablation of hepatic tumors, which is a surgical procedure in which a needle-like device is inserted into the center of a cancerous lesio n and is energized in a way so as to burn and effectively remove the timorous tissue. A promising alternative to surgical resection, this approach has several advantages over traditional resection, including reduced trauma and recovery time for the patie nt, but it requires significant skill with ultrasonography for guidance in the careful placement of the probe that is required for maximization of tumor destruction, and minimization of healthy tissue destruction. The system proposed here will allow even a novice surgeon to place the probe accurately and quickly, and can enable an expert surgeon to perform the procedure more quickly.

Principal Investigator:

Sharif Razzaque
9197322090
SHARIF@INNEROPTIC.COM

Business Contact:

Caroline Green
caroline@inneroptic.com
Small Business Information at Submission:

INNEROPTIC TECHNOLOGY, INC.
PO BOX 824 CHAPEL HILL, NC 27514

EIN/Tax ID: 104366771
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No