USA flag logo/image

An Official Website of the United States Government

PYROELECTRIC THIN POLYMER FILMS

Award Information

Agency:
Department of Energy
Branch:
N/A
Award ID:
3426
Program Year/Program:
1986 / SBIR
Agency Tracking Number:
3426
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
Ohmicron Corp.
375 Pheasant Run Newtown, PA 18940
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 1986
Title: PYROELECTRIC THIN POLYMER FILMS
Agency: DOE
Contract: N/A
Award Amount: $49,843.00
 

Abstract:

THE BIOSENSOR FIELD IS MULTIDISCIPLINARY, ENCOMPASSING MANY TYPES OF MEASURING TECHNIQUES AND DEVICES. THERMOMETRIC ANDMICROCALORIMETRIC TECHNIQUES FOR ENZYMATIC AND IMMUNOENZYMATIC ANALYSIS HAVE YIELDED GOOD RESULTS; HOWEVER,TO DATE, THE METHODS AND EQUIPMENT REMAIN RELATIVELY COMPLEX, EXPENSIVE, AND, THEREFORE, NOT ROUTINELY EMPLOYED. WE PROPOSE TO DEVELOP A SENSITIVE, DIFFERENTIAL MICROCALORIMETRIC BIOSENSOR DEVICE USING THIN POLYMER FILMS DISPLAYING A PYROELECTRIC RESPONSE. POLYVINYLIDENE FLUORIDE (PVDF) FILMS ARE CAPABLE OF DETECTING THE HEAT OF AHUMAN BODY UP TO FIFTY FEET AWAY AND HAVE RECENTLY BEEN EMPLOYED IN VARIOUS 1R DETECTORS AS WELL AS IN PIEZOELECTRIC TRANSDUCER APPLICATIONS. BY EMPLOYING TECHNIQUES SIMILAR TO MICRO-CIRCUIT FABRICATION, WE ANTICIPATE CONSTRUCTING A SIMPLE ENZYME AND IMMUNOENZYME BASED BIOSENSOR DEVICE WHICH IS LOW IN COST AND, BY NATURE OF THE FABRICATION, PROVIDES FOR A SINGLE STEP, SINGLE PHASE"HOMOGENEOUS" ENZYME IMMUNOASSAY FORMAT. A DISTINCT ADVANTAGE OF A CALORIMETRIC BASED BIOSENSOR DEVICE IS THAT AWIDE RANGE OF ANALYSES CAN BE PERFORMED AND THE SPECIFICITY DETERMINED BY THE CHOICE OF BIOLOGGICAL PROCESSES WITHOUT THE POTENTIAL INTERFERENCES ENCOUNTERED BY METHODS SUCH AS SPECTROPHOTOMETRY OR FLUOROMETRY. FURTHER, UNLIKE CALORIMETRIC TECHNIQUES USING THERMISTORS OR THERMOPILES, PYROELECTRIC FILMS CAN BE FABRICATED TO EXTREMELY CLOSE PHYSICAL TOLERANCES BY SIMPLE MEANS AND OPERATED IN A DIFFERENTIAL MODE, IRRESPECTIVE OF THE ABSOLUTE TEMPERATURE.IN EFFECT, WE PROPOSE TO EVALUATE TECHNIQUES THAT CAN SIGNIFICANTLY IMPROVE UPON AND SIMPLIFY THE CLASSICAL ANALYTICAL METHODS OF THERMOMETRY AND MICROCALORIMETRY.

Principal Investigator:

Mark k. malmros
PRINCIPAL INVESTIGATOR
6097379050

Business Contact:

Small Business Information at Submission:

Ohmicron Corpon
108 West Franklin Avenue Pennington, NJ 08520

EIN/Tax ID:
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No