USA flag logo/image

An Official Website of the United States Government

Company Information:

Company Name: Opteos, Inc.
City: Ann Arbor
State: MI
Zip+4: -
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Website URL: http://www.opteos.us
Phone: (734) 332-6075

Award Totals:

Program/Phase Award Amount ($) Number of Awards
SBIR Phase I $369,959.00 4
SBIR Phase II $1,749,859.00 2
STTR Phase I $199,991.00 2
STTR Phase II $1,499,027.00 2

Award List:

MINIATURIZED ELECTRO/MAGNETO-OPTIC SENSORS FOR THE DETECTION AND MEASUREMENT OF BROADBAND RF PULSES

Award Year / Program / Phase: 2004 / STTR / Phase I
Agency / Branch: DOD / USAF
Research Institution: University of Michigan
Principal Investigator: Kyoung Yang, President
Award Amount: $99,991.00
RI Contact: John F. Whitaker
Abstract:
An innovative electromagnetic wave detection and measurement system based on broadband, non-intrusive, miniaturized electro-optic (EO) and magneto-optic (MO) sensors will be developed in order to evaluate the effects caused by short duration burst or pulsed EM waves incident on electronic circuits.… More

Nonlinear-Optical-Based Vector Electric and Magnetic Near-Field Probing for Analysis of Electromagnetic Compatibility

Award Year / Program / Phase: 2004 / STTR / Phase I
Agency / Branch: DOD / ARMY
Research Institution: University of Michigan
Principal Investigator: Kyoung Yang, President
Award Amount: $100,000.00
RI Contact: John F. Whitaker
Abstract:
The determination of the feasibility of utilizing optically-interrogated electro-optic and magneto-optic sensors as the front-end of a new, near-field characterization system for measuring time-varying, non-sinusoidal signals in microwave digital and mixed-signal circuits is proposed. The… More

A Network of Multi-band Sensors for Radar Design, Deployment, and Diagnostics

Award Year / Program / Phase: 2004 / SBIR / Phase I
Agency: NASA
Principal Investigator: Kyoung Yang, Principal Investigator
Award Amount: $69,982.00
Abstract:
Limitations on the design, monitoring and diagnosis of complex microwave systems due to insufficient models, the reality of imperfect physical conditions, and the reliance on trial-and-error iteration for system improvement serve to increase the time and costs of radar development. While microwave… More

Radar Systems Technology Innovative Concepts

Award Year / Program / Phase: 2005 / SBIR / Phase I
Agency / Branch: DOD / MDA
Principal Investigator: Kyoung Yang, President
Award Amount: $99,985.00
Abstract:
The goal of this SBIR project is the development of an Electro-optic Sensor Network (ESN) system that can be directly embedded into large-scale phased antenna arrays for accurate on-site array calibration, real-time fault isolation, and performance monitoring. This will be accomplished through… More

MINIATURIZED ELECTRO/MAGNETO-OPTIC SENSORS FOR THE DETECTION AND MEASUREMENT OF BROADBAND RF PULSES

Award Year / Program / Phase: 2006 / STTR / Phase II
Agency / Branch: DOD / USAF
Research Institution: UNIV. OF MICHIGAN
Principal Investigator: Kyoung Yang, President
Award Amount: $749,997.00
RI Contact: Anna M. Schork
Abstract:
An innovative, high-speed electromagnetic-wave-detection system based on broadband, non-intrusive, miniaturized electro-optic (EO), magneto-optic (MO), and electro-optic voltage (EOV) sensors will be developed for evaluating the effects that pulsed electromagnetic (EM) waves have on specific… More

Nonlinear-Optical-Based Vector Electric and Magnetic Near-Field Probing for Analysis of Electromagnetic Compatibility

Award Year / Program / Phase: 2006 / STTR / Phase II
Agency / Branch: DOD / ARMY
Research Institution: UNIV. OF MICHIGAN
Principal Investigator: Kyoung Yang, President
Award Amount: $749,030.00
RI Contact: Anna M. Schork
Abstract:
An innovative, optically-interrogated test instrument, based on broadband, non-intrusive, miniaturized electro-optic (EO), magneto-optic (MO), and electro-optic voltage (EOV) sensors, will be developed for evaluating the operation of, and the electromagne

Innovative Radar System Concepts and Architectures

Award Year / Program / Phase: 2006 / SBIR / Phase I
Agency / Branch: DOD / MDA
Principal Investigator: Kyoung Yang, President
Award Amount: $99,995.00
Abstract:
The goal of this SBIR project is the development of a fiber-coupled diagnostic system for the comprehensive Tx/Rx-mode calibration and performance-monitoring of large-scale phased antenna arrays. In the proposed calibration system, innovative electro-optic (EO) field sensors will monitor near-field… More

Fiber-Coupled Array Calibration System for On-Site Tx/Rx-Mode Calibration of Large-Scale Phased Antenna Arrays

Award Year / Program / Phase: 2007 / SBIR / Phase II
Agency / Branch: DOD / MDA
Principal Investigator: Kyoung Yang, President
Award Amount: $999,897.00
Abstract:
The goal of this SBIR project is the development, assembly, and functional test of a prototype fiber-coupled diagnostic system for the comprehensive calibration and performance monitoring of large scale phased-antenna arrays. In the proposed calibration system, innovative electro-optic (EO) field… More

Short Pulse Radio Frequency (RF) Field Measurement System

Award Year / Program / Phase: 2010 / SBIR / Phase I
Agency / Branch: DOD / USAF
Principal Investigator: Jack Thiesen, Director of Engineering
Award Amount: $99,997.00
Abstract:
Opteos Inc. is responding to an Air Force request to develop a rugged field-portable multi-channel measurement system with non-perturbing probes capable of measuring and displaying real time waveforms from RF pulses with frequency components from 3 kHz to 100 GHz and peak field strengths of 2 MV/m… More

Short Pulse Radio Frequency (RF) Field Measurement System

Award Year / Program / Phase: 2011 / SBIR / Phase II
Agency: DOD
Principal Investigator: Jack Thiesen, Director of Engineering – (734) 929-3333
Award Amount: $749,962.00
Abstract:
ABSTRACT: Opteos Inc. is proposing a new approach to the measurement of electric fields based on the electrooptics principles. This system promises an extremely high bandwidth of operation, 50GHz to 100GHz, a wide dynamic range up to 60dB, and high accuracy better than 1% full scale. The system is… More