USA flag logo/image

An Official Website of the United States Government

An Automated, High Throughput, Filter-Free Pathogen Preconcentrator

Award Information

Agency:
Department of Defense
Branch:
Army
Award ID:
94898
Program Year/Program:
2010 / STTR
Agency Tracking Number:
A10A-016-0112
Solicitation Year:
N/A
Solicitation Topic Code:
ARMY 10T016
Solicitation Number:
N/A
Small Business Information
CFD Research Corporation
215 Wynn Dr., 5th Floor Suite D Huntsville, AL 35805-
View profile »
Woman-Owned: Yes
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2010
Title: An Automated, High Throughput, Filter-Free Pathogen Preconcentrator
Agency / Branch: DOD / ARMY
Contract: W911SR-10-C-0081
Award Amount: $99,977.00
 

Abstract:

Accurate real-time waterborne pathogen detection is of paramount importance to security of U.S. military forces and installations. Fieldable high-throughput pathogen concentration is a critical analytical need for enhanced detection performance. Existing concentration methods are time-consuming, bulky, labor-intensive, power- and reagent-hungry, and consequently ill-suited for battlefield deployment and on-site investigation. To overcome these limitations, we propose to develop and demonstrate a high-throughput, filter-free preconcentrator for automated enrichment of threat pathogens in water samples. The underlying principle of our preconcentrator is to form contactless exclusion barriers to pathogens by combining cross flow features and dielectrophoresis. Our technology enables order-of-magnitude improvement in throughput, concentration factor, and recovery efficiency and significant reduction in logistical burden and operating cost. In Phase I, we will design, fabricate, characterize and demonstrate a laboratory-scale prototype to establish proof-of-principle of the proposed technology. The preconcentrator designs will be optimized using high-fidelity simulation tools, and the fabricated device will be tested and demonstrated in our well-equipped bioengineering laboratories. In Phase II, a quarter-scale preconcentrator system with additional design refinements will be developed for enhanced performance, integrability and manufacturability. The preconcentrator will be integrated with COTS technologies for automated operation. The Phase II prototype will be demonstrated for continuous, long-term concentration of threat pathogens from composite sample matrix. Design requirements for full-scale system and compatibility to various detection technologies will be identified. The final product will be fully automated and filter-free with readily deployability in research and real environments.

Principal Investigator:

Yi Wang
Group Leader
2563270678
tsb@cfdrc.com

Business Contact:

Deb Phipps
Sr. Contract Specialist
2567264884
dap@cfdrc.com
Small Business Information at Submission:

CFD Research Corporation
215 Wynn Dr., 5th Floor Huntsville, AL 35805

EIN/Tax ID: 630944385
DUNS: N/A
Number of Employees:
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
RTI International
3040 Cornwallis Road
Research Triangle Pk, NC 27709
Contact: Sonia Grego
Contact Phone: 9192484181