You are here
XIA LLC
UEI: J26GQK3R6773
# of Employees: 16
HUBZone Owned: No
Socially and Economically Disadvantaged: No
Woman Owned: No
Award Charts
Award Listing
-
NEXT Neutron Detector Modules based on High Density SiPM Arrays and Novel Organic Glass Scintillator
Amount: $200,000.00To maximize its research potential The Facility for Rare Isotope Beams FRIB) requires a neutron tracking array NEXT) with both efficiency and energy resolution at least three times better than the cur ...
SBIRPhase I2020Department of Energy -
Small-molecule organic glass scintillators for improved neutron detector arrays
Amount: $154,995.00Detecting fast neutrons in the presence of gamma-rays is not only important to the advancement of nuclear physics at national laboratories like FRIB but also critical in various national security appl ...
SBIRPhase I2018Department of Energy -
Distributed digital data acquisition system with network time synchronization
Amount: $1,010,000.00Large scale nuclear physics experiments often use arrays of radiation detectors, which can be physically separated – in different rooms, near and remote to a target, and/or at different positions in ...
SBIRPhase II2018Department of Energy -
Distributed digital data acquisition system with network time synchronization
Amount: $154,158.00Large scale nuclear physics experiments often use arrays of radiation detectors. Arrays from the same experiment can be physically separated – in different rooms, near and remote to a target, and/or ...
SBIRPhase I2017Department of Energy -
Ultra Low Background Time Projection Alpha Particle Detector
Amount: $1,010,000.00The search for rare-events, such as double beta decay or dark matter detections, is primarily a fight to reduce the incidence of background events to sufficiently low levels so that the events of inte ...
SBIRPhase II2017Department of Energy -
Ultra low background time projection alpha particle detector
Amount: $155,000.00The search for rare-events, such as double beta decay or dark matter detections, is primarily a fight to reduce the incidence of background events to sufficiently low levels so that the events of inte ...
SBIRPhase I2016Department of Energy -
A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy
Amount: $150,000.00The detection and identification of special nuclear materials and nuclear fission by-products is a critically important activity in support of nuclear non-proliferation programs. Gamma-ray spectrosco ...
SBIRPhase I2014Department of Energy -
Portable??/?? Scintillation Detector with Improved RadioxeNon MDC's
Amount: $150,000.00Radioxenon detection is an important component in both the nation & apos;s and the CTBTO & apos;s programs for nuclear explosion monitoring. Existing detectors (SAUNA, PhosWatch, SPALAX & amp; ARIX) c ...
SBIRPhase I2014Department of Energy -
Semiconductor detectors with optimized proximity signal readout
Amount: $1,000,000.00Semiconductor-based radiation detectors are used in detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astr ...
SBIRPhase II2014Department of Energy -
High Speed, Multi-Channel, User Programmable Digital Data Acquisition System
Amount: $150,000.00As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout elect ...
SBIRPhase I2013Department of Energy