USA flag logo/image

An Official Website of the United States Government

Volume Tomographic Angiography Imaging (VTAI)

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
22393
Program Year/Program:
1993 / SBIR
Agency Tracking Number:
22393
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
Xre Corp.
300 Foster Street, Box 1154 Littleton, MA 01460
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 1993
Title: Volume Tomographic Angiography Imaging (VTAI)
Agency: HHS
Contract: N/A
Award Amount: $49,500.00
 

Abstract:

Identification of patients who will benefit from specific therapeutic procedure requires the accurate assessment of the severity of stenoses, their geometry and spatial orientation. Most therapeutic decisions are currently based on information obtained through digital angiography. Standard angiographic images may not provide angiographers with sufficient information needed to make therapeutic decisions. The long-term goal of this project is to develop a volume tomographic angiography imaging (VTAI) technique to provide angiographers with useful 3-D vascular images needed for diagnostic and therapeutic decisions. VTAI combines volume tomographic imaging principles with those of digital angiography. VTAI may require only a single contrast injection and volume scan to provide a true 3-D description of vascular anatomy and stenoses in head, neck and abdomen. This project (Phase I) is an attempt to improve the performance of certain 3-D reconstruction algorithms for use with real time 2-D angiographic images generated by a specially designed rotational angiographic digital imaging (ROAD) system. A specially modified CT gantry has been equipped with an image intensifier subsystem to model the ROAD system. This work has been completed and will be used to provide model data sets for the software research effort. The clinical significance of this technique is to simplify the procedure, reduce the amount of injected contrast media, and total x-ray dose and the procedure time. This technique will supply the angiographer with a direct, unambiguous and accurate measurement of the severity of the stenoses, their geometry and spatial orientation, and allowing optimal randomly oriented viewing of vascular structures during a post processing diagnostic session.

Principal Investigator:

John K. Grady
5084869681

Business Contact:

Small Business Information at Submission:

Xre Corp.
300 Foster Street, Box 1154 Littleton, MA 01460

EIN/Tax ID:
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No