Overcoming limitations of breast volume imaging in 3D dedicated mammotomography

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
85411
Program Year/Program:
2007 / SBIR
Agency Tracking Number:
CA125924
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
ZUMATEK, INC.
870 MARTIN LUTHER KING JR. BLVD. CHAPEL HILL, NC 27514
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2007
Title: Overcoming limitations of breast volume imaging in 3D dedicated mammotomography
Agency: HHS
Contract: 1R43CA125924-01A1
Award Amount: $100,000.00
 

Abstract:

DESCRIPTION (provided by applicant): The emergence of compact, high-quality digital X-ray imaging detectors, together with nearly exponential growth in computing power and corresponding price reductions, allows for the potential of dedicated 3D breast ima ging. X-ray mammography (XRM) has recognized limits including relatively high false negative rates. Other disadvantages include breast compression, relatively high dose to the breast, and low positive predictive value, especially for radiographically dense breasts. The dedicated breast Computed mammoTomography (CmT) solution we are proposing has the potential for improved detection of breast lesions through the removal of contrast-reducing overlying tissue, as well as the added benefits of uncompressed brea st imaging for greater patient comfort, and breast dose equal to or less than that of current dual view mammography. Ultimately, we expect this technology to result in improved positive predictive value with earlier cancer detection and reduced morbidity a nd mortality. In the long term, we seek to demonstrate the feasibility of this device in a clinical setting by overcoming the current limitations in imaging the full breast volume and chest wall. These physical limitations are currently imposed by the fact that the X-ray tube and detector must trace an orbital path which includes moving under a patient support. For other standard designs, this makes it difficult to image close to the chest wall, though our prototype device has the 3-dimensional positionin g capability to potentially overcome some of these limitations. Specific Aim 1 will investigate of partial angle tomographic scanning using the patient bed to move the breast further into the field of view to capture the entire breast and chest wall while limiting the orbit of the device to the sides of the bed. The assembly will be placed under a patient bed at the Multi-Modality Imaging Lab (MMIL) at Duke University Medical Center and partial angle scans made of available torso, breast, and lesion phantom s. Observers will determine the extent of visibility of lesions close to the chest wall. Specific Aim 2 will demonstrate the feasibility of utilizing current patient bed vertical elevation capabilities to change the relationship between breast and system c enter of rotation during scans to provide full 360 degree acquisitions while avoiding patient bed limitations. A patient bed with multiple degrees of freedom of movement will be used to lower the patient phantom further into the field of view while the dev ice is perpendicular to the bed axis, then raise the bed to allow to device to move under the bed. Results will be evaluated as in Specific Aim 1. Specific Aim 3 will model patient bed designs to determine the degree to which the chest wall can be moved in to the field of view with reasonable patient comfort by potentially utilizing smooth bed contours around a patient's hips and head. Successful implementation of the above alternatives, pending results of Phase I, will result in a next generation advanced s ystem being produced in Phase II that can be placed in a clinical setting for the beginning of patient studies, leading to a commercially available product.

Principal Investigator:

Randolph L. Mckinley
9192253965
RANDOLPH.MCKINLEY@ZUMATEK.COM

Business Contact:

Randolph L. Mckinley
rmckinley@zumatek.com
Small Business Information at Submission:

ZUMATEK, INC.
870 MARTIN LUTHER KING JR. BLVD. CHAPEL HILL, NC 27514

EIN/Tax ID: 120447538
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No