USA flag logo/image

An Official Website of the United States Government

Bedside Monitor to Quantify Cardiac Shunt Flow in Newborns and Small Children

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2011 / SBIR
Agency Tracking Number:
R43HL111852
Solicitation Year:
2011
Solicitation Topic Code:
NHLBI
Solicitation Number:
HD10-012
Small Business Information
TRANSONIC SYSTEMS, INC.
34 DUTCH MILL RD ITHACA, NY -
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2011
Title: Bedside Monitor to Quantify Cardiac Shunt Flow in Newborns and Small Children
Agency: HHS
Contract: 1R43HL111852-01
Award Amount: $450,000.00
 

Abstract:

DESCRIPTION (provided by applicant): There is no current technology for routine measurement of shunt flow (Qp:Qs - ratio of pulmonary to systemic blood flow) in newborns and small children in the intensive care unit (ICU). Current methods either require placement of highly invasive catheter or depend on assumptions, leading to risky and less accurate measurement of shunt flow. Timely and accurate quantitative assessment of Qp/Qs permits successful pharmacologic, ventilator or fluid therapy or in time surgical intervention. Hence routine measurement of shunt flow is vital in the management of critically ill newborn and small children with cardiac defects. This SBIR grant will allow us to develop mathematical models and algorithms accounting for various shunts, clinical and physiological conditions. These will then be implemented into a monitor that could be used clinically at the bedside in a non-invasive manner with patients having in situ arterial and central venous catheters. The approach is based on well-established indicator dilution principles using innocuous isotonic saline as an indicator. These factors make the proposed monitor eminently suitable for used with neonatal and pediatric ICU patients. Main objectives of this proposal include - 1) Development of mathematical models and software algorithms for accurately quantifying shunt flow 2) Perform feasibility and validation testing of shunt flow measurements in animal models 3) Perform feasibility and clinical comparison of shunt flow measurements in newborns and small children. These objectives will be achieved in a concerted effort by Transonic's RandD staff, and its collaborators at University of Pittsburgh, PA and Crouse Hospital, NY. Successfully accomplishing Phase-I goals will test the feasibility of the proposed approach and guide further research to develop and clinically validate the first of its kind Bedside monitor for quantitative measurement of shunt flow in critically ill newborns and small children. PUBLIC HEALTH RELEVANCE: Accurate measurement of shunt flow (Qp:Qs - ratio of pulmonary to systemic blood flow) is vital for treating newborns and small children with congenital heart defects. Despite its clinical importance there currently exists no method that could be routinely used with this vulnerable patient population to accurately measure shut flow at the patient's bedside. Proposed monitor would allow neonatal and pediatric clinicians to routinely monitor shunt flow at the bedside for the first time. This would give them an opportunity to better manage the care of critically ill with cardiac shunts by providing accurate and timely assessment of Qp:Qs which could be used to assess the efficacy of therapy in real-time and thereby prevent related patient morbidity and mortality, andultimately reduce short and long-term health care costs. The projected commercial success is based on the clear need in neonatal and pediatric ICUs for a simple, minimally invasive tool for quantitatively assessing shunt flow during the care of patients with congenital cardiac defects.

Principal Investigator:

Nikolai M. Krivitski
607-257-5300
nikolai.krivitski@transonic.com

Business Contact:

Bruce Kilmartin
607-257-5300
bruce.kilmartin@transonic.com
Small Business Information at Submission:

TRANSONIC SYSTEMS, INC.
34 DUTCH MILL RD ITHACA, NY -

EIN/Tax ID: 116120571
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No