USA flag logo/image

An Official Website of the United States Government

MicroFlex Technology for Early Detection of Lung Disease

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2011 / STTR
Agency Tracking Number:
R42HL083331
Solicitation Year:
2011
Solicitation Topic Code:
NHLBI
Solicitation Number:
PA10-051
Small Business Information
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2011
Title: MicroFlex Technology for Early Detection of Lung Disease
Agency: HHS
Contract: 2R42HL083331-03A2
Award Amount: $1,279,892.00
 

Abstract:

DESCRIPTION (provided by applicant): MicroFlex Technology for Early Detection of Lung Cancer Project Summary MicroFlex technology will provide unprecedented flexibility and controllability for bronchoscopes, enabling minimally invasive bronchoscopy to reach previously inaccessible peripheral bronchi and provide direct visualization and tool manipulation capabilities for diagnostic and therapeutic procedures. MicroFlex technology combines innovations in actuation, sensing, control and assembly to produce anultra-slim digitally controlled bronchoscope more flexible and controllable than currently possible. This technology promises to improve detection, for example of early-stage lesions, and provide more accurate diagnoses to improve cure rates for lung cancer and other lung diseases. This project will refine technology proven in the Phase I study to design, fabricate and functionally test novel 1mm diameter actively-guided MicroFlex Tool prototypes for bronchoscopy procedures. A lung-specific MicroFlex devicewill be developed, built and tested in the laboratory for force and motion capabilities, a control manipulative and associated control electronics and software will be developed, and pulmonologists will test the integrated system in-vivo in animals for function and usability. Since MicroFlex tools are controlled by temperature change in internal actuators, thermal effects of contacting bronchial epithelial tissue will be studied for thermal tissue damage and validation of thermal control models. Effectiveness of a prototype MicroFlex device including a Guide Catheter and MicroFlex Tool will be evaluated in accessing peripheral sites down to a 1mm bronchiole diameter, visualizing tissue, placing markers and performing tissue sampling. MicroFlex technology, fabrication processes and prototypes will be refined by integrating input from experienced bronchoscopists, engineers with expertise in medical product design, and prospective Phase III manufacturing partners and suppliers of complementary technology. Potential Phase III manufacturing partners will be identified and utilized for Phase II prototype components, where possible, to accelerate the commercialization process. PUBLIC HEALTH RELEVANCE: MicroFlex Technology for Early Detection of Lung Cancer Project Narrative Lung cancer is the leading cause of cancer-related deaths in the United States, and despite advances in treatment the prognosis remains poor with a less than 15% five year survival rate, due to the difficulty of early stage detection and diagnosis. Bronchoscopy is used to diagnose various lung diseases, but current bronchoscopes are too large and too limited in flexibility and control to reach most of the peripheral lung. MicroFlex technology enables a 1mm diameter, ultra-flexible, actively-guided, digitally-controlled bronchoscope that can access nearly all locations in the lung to about the 15th bronchial branch. This bronchoscope is compatible with state of the art electromagnetic navigation, and provides direct visualization and dexterousMicroFlex tools for accurate tissue sampling and therapeutic agent delivery in the airways and pleural space.

Principal Investigator:

Dale A. Lawrence
303-250-7777
dale.lawrence@colorado.edu

Business Contact:

Alan Kopelove
303-250-7777
alank@quest-corp.com
Small Business Information at Submission:

QUEST PRODUCT DEVELOPMENT CORPORATION
6833 Joyce Street Arvada, CO -

EIN/Tax ID: 184133015
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
UNIVERSITY OF COLORADO
University of Colorado Denver
Grants and Contracts, Mail Stop F428 Anschutz Medical Campus, Building 500 13001
AURORA, CO 80045-0508
Contact: