You are here

A Portable High Resolution Detector for Rapid Field Arsenic Test in Drinking Wate

Award Information
Agency: Department of Health and Human Services
Branch: Centers for Disease Control and Prevention
Contract: 2R44EH000385-02
Agency Tracking Number: R44EH000385
Amount: $499,140.00
Phase: Phase II
Program: SBIR
Solicitation Topic Code: NCEH
Solicitation Number: PA10-050
Timeline
Solicitation Year: 2011
Award Year: 2011
Award Start Date (Proposal Award Date): N/A
Award End Date (Contract End Date): N/A
Small Business Information
AGILTRON, INC. 15 CABOT RD
WOBURN, MA 01801-1003
United States
DUNS: 004841644
HUBZone Owned: No
Woman Owned: No
Socially and Economically Disadvantaged: No
Principal Investigator
 KING WANG
 (781) 935-1200
 kwang@agiltron.com
Business Contact
 KING WANG
Phone: (781) 935-1200
Email: acontardo@agiltron.com
Research Institution
 Stub
Abstract

DESCRIPTION (provided by applicant): The combination of high toxicity and widespread occurrence has created a pressing need for effective monitoring of arsenic in groundwater. Through this program Agiltron will develop a field deployable monitoring tool based on surface enhanced Raman spectroscopy (SERS) for rapid on-site detection and quantification of arsenic in groundwater. During operation in the field, the SERS sensor module can be inserted directly into samples of groundwater brought up to the surfaceor lowered directly into the water well with the use of long fiber length for on-site arsenic detection and quantification. The proposed system will be able to detect arsenic in groundwater at 1 ppb concentration level, in situ, on-site, with little or nosample preparation, and with no interferences. During Phase I we have successfully demonstrated the detection of 1 ppb level arsenic in water samples using the proposed portable SERS system. In Phase II the performance of the proposed SERS system will beoptimized for highest throughput at the wavelength of interest by using suitable excitation wavelength and SERS substrates with optimized localized surface plasmon resonance properties. On-site measurement of arsenic in groundwater in local water wells will be conducted. The feedback from these field studies will be used to further develop/improve the performance of individual components so that an optimized monitoring system suitable for practical site operation can be developed and are ready for manufacture. PUBLIC HEALTH RELEVANCE: As one of the most common contaminants in groundwater worldwide, Arsenic is a well-known toxic chemical that the Environmental Protection Agency and the World Health Organization list as a known carcinogen. The World Health Organization and US guidelines recommend the arsenic values in drinking water to be no more than 10 mg/L (ppb). The proposed portable arsenic detection system can enable the detection of arsenic in groundwater at 1 ppb concentration level, in situ, on-site, with little or no sample preparation, and with no interferences.

* Information listed above is at the time of submission. *

US Flag An Official Website of the United States Government