USA flag logo/image

An Official Website of the United States Government

Improving liver lesion biopsy in the CT suite through fusion with PET images

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2010 / STTR
Agency Tracking Number:
R41CA153488
Solicitation Year:
2010
Solicitation Topic Code:
NCI
Solicitation Number:
PA09-081
Small Business Information
Kitware
28 Corporate Drive Clifton Park, NY 12065-
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2010
Title: Improving liver lesion biopsy in the CT suite through fusion with PET images
Agency: HHS
Contract: 1R41CA153488-01
Award Amount: $228,458.00
 

Abstract:

DESCRIPTION (provided by applicant): The broad objective of this proposal is to improve the clinical effectiveness of liver lesion biopsy by fusing respiratory-compensated PET with CT images in the CT suite. On CT imaging alone, localization of liver lesions can potentially be challenging, particularly in selected cases where differentiation of the tumor from adjacent liver parenchyma may be difficult. Given the ability of PET to localize malignancies in situations where the same tumors do not have a CT correlate, we believe that PET-CT guided biopsy would improve the diagnostic yield of liver lesion biopsies by providing guidance in targeting a metabolically active lesion or a specific metabolic hot spot within a larger liver lesion. However, the diagnostic benefit of using PET scans (even from hybrid PET/CT machines) is gravely affected by respiratory motion artifacts. CT data is acquired in a short time representing an instantaneous snapshot during the breathing cycle. On the other hand, PET data acquisition takes an average 3-10 minutes per gantry table position. For typical procedures, 5 -7 gantry positions are required on average. These prolonged acquisition times lead to respiratory motion artifacts in the images. These artifacts, in turn, cause discrepancy in spatial correspondence between the CT and PET data, inaccurate tumor localization, and incorrect tumor staging. Hence, development of an effective PET-CT guided biopsy for liver lesions requires a robust respiratory motion correction technique.We propose to develop respiratory motion correction and registration components suitable for abdominal imaging and extend our open source image-guided surgery system (IGSTK) to enable PET/CT guided liver lesion biopsy in the CT suite. The respiratory motion correction algorithm will utilize phase matched respiratory-gated PET and CT data and super- resolution reconstruction algorithm to generate a motion-free high quality PET image. We will develop a novel image registration algorithm that will compensatefor respiration-induced organ- sliding. Organ-sliding is not handled well by traditional registration methods which assume that one image can be smoothly deformed into the next. PUBLIC HEALTH RELEVANCE: PET/CT imaging plays a key role in early detection, staging, and evaluation of suspicious lesions. PET imaging provides information on functional or metabolic characteristics of tumors, whereas CT predominately assesses the tumor's anatomical and morphological features. By fusing these two imaging techniques and incorporating advanced image registration and respiratory motion compensation techniques, clinicians can effectively biopsy liver lesions.

Principal Investigator:

Kevin R. Cleary
202-476-3809
cleary@georgetown.edu

Business Contact:

Stephen Aylward
919-969-6990
stephen.aylward@kitware.com
Small Business Information at Submission:

KITWARE, INC.
28 Corporate Drive SUITE 204 Clifton Park, NY -

EIN/Tax ID: 114180269
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
George Washington University
Office Of The Vice President For Research
2121 Eye St Nw, Ste 601
WASHINGTON, DC 20052-
Contact: