USA flag logo/image

An Official Website of the United States Government

Advanced Refrigeration System for Non-Lethal Direct Energy Weapon System

Award Information

Agency:
Department of Defense
Branch:
N/A
Award ID:
Program Year/Program:
2011 / SBIR
Agency Tracking Number:
N102-110-1052
Solicitation Year:
2010
Solicitation Topic Code:
N102-110
Solicitation Number:
2010.2
Small Business Information
Advanced Cooling Technologies, Inc.
1046 New Holland Avenue Lancaster, PA 17601-
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2011
Title: Advanced Refrigeration System for Non-Lethal Direct Energy Weapon System
Agency: DOD
Contract: M67854-11-C-6506
Award Amount: $69,985.00
 

Abstract:

The Non-Lethal Direct Energy Weapon (NLDEW) system, including ADT and RF Vehicle Stopper, has significant cooling requirements that can be addressed by mechanical refrigeration systems. These include cooling of various high powered ADT solid state array or RF vehicle stopper vacuum microwave power electronics during short period of"ON"time, as well as long duration of"standby"cooling. The proposed"Advanced Refrigeration System for Non-Lethal Direct Energy Weapon System"uses a design similar to flat plate heat exchanger to offer an innovative and reliable technology to reduce the weight and volume of NLDEW, while providing improved performance, reliability and maintainability. In the proposed project, Advanced Cooling Technologies, Inc., supported by Villanova University, will develop an advanced vapor compression refrigeration system consisting of two key components: a load leveling heat exchanger with high thermal conductive Phase Change Material embedded with Graphite Nanofibers, and a highly integrated heat exchanger combining the evaporator, condenser and subcooler, to meet NLDEW cooling requirements. Phase I will demonstrate the feasibility of the concept through system trades, integration study and preliminary prototype testing. Phase II will design, build and test a full scale system, and demonstrate its ability to support NLDEW cooling requirements.

Principal Investigator:

Xudong Tang
R&D Engineer
(717) 295-6061
xudong.tang@1-act.com

Business Contact:

Jon Zuo
President
(717) 295-6058
jon.zuo@1-ACT.com
Small Business Information at Submission:

Advanced Cooling Technologies, Inc.
1046 New Holland Avenue Lancaster, PA -

EIN/Tax ID: 571146896
DUNS: N/A
Number of Employees:
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No