USA flag logo/image

An Official Website of the United States Government

Point of Care Detection of Respiratory Viruses

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2012 / SBIR
Agency Tracking Number:
R44AI081467
Solicitation Year:
2012
Solicitation Topic Code:
NIAID
Solicitation Number:
PA10-123
Small Business Information
LUCIGEN CORPORATION
2905 PARMENTER ST. Middleton, WI 53562-2547
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2012
Title: Point of Care Detection of Respiratory Viruses
Agency: HHS
Contract: 2R44AI081467-02
Award Amount: $2,685,965.00
 

Abstract:

DESCRIPTION (provided by applicant): Respiratory infections have a significant health and economic impact worldwide. Current test products for the diagnosis of respiratory viral infections such as influenza are inadequate for the timely diagnosis needed for successful implementation of antiviral treatment. Unfortunately a test product that can accurately diagnose common respiratory viruses with high confidence in less than 30 minutes directly at point of need has not yet been developed. We propose to develop an innovative device and reagents for the molecular diagnosis of multiple RNA pathogens that will set a new standard for rapid patient care. This application entitled Point of Care Detection of Respiratory Viruses seeks to develop a turnkey solutionfor the processing, detection, and digital readout of influenza viruses A and B, as well as respiratory syncytial virus (RSV) in 30 minutes. Training requirements for personnel operating the device are minimal. The combination of novel molecular technologies, simple protocol, and affordable multiplex testing capabilities residing in a single, inexpensive device wil enable near point of care diagnostics for a number of serious infectious agents. The research design for achieving this goal includes four processing elements: 1) A one step sample prep that can be completed in a minute, 2) Isothermal amplification of viral RNA in 20 minutes, 3) multiplex sequence specific detection of influenza A, influenza B and RSV including built in standards in a few minutes, and 4) a digital readout of results in electronic form. These steps all occur within a small 4 x 6 inch instrument containing a disposable reagent cartridge. A key factor enabling this game changing technology is the development of a novel enzyme that converts RNA to DNA and isothermally amplifies it in minutes. These attributes have allowed the design of a device that does not use any microfluidics, pumps or valves. The greatly simplified construction significantly reduces the cost. This new technologyis ideal for to low resource and battlefield settings, and has long term potential as an over the counter device. The test device and reagents developed as part of this application will be validated in a clinical setting with outside experts. During PhaseIII of the project we will apply for FDA clearance of the instrument and reagents and commercialize the diagnostic device in the US and other markets around the globe. PUBLIC HEALTH RELEVANCE: The goal of this application is to develop a simple but inexpensive nucleic acid based test device that can diagnose human respiratory viral illness in less than 30 minutes at point of care. Because treatment regimens for respiratory disease differ widely depending on the causative agent, the development, FDA-approval and eventual commercialization of this new clinical diagnostic product would have profound health care benefits for patients and their providers by allowing timely diagnosis to inform both antiviral and antibiotic therapies.

Principal Investigator:

Michael J. Moser
608-831-9011
mmoser@lucigen.com

Business Contact:

Michael J. Moser
608-831-9011
mmoser@lucigen.com
Small Business Information at Submission:

LUCIGEN CORPORATION
2905 Parmenter St. MIDDLETON, WI -

EIN/Tax ID: 139192330
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No