USA flag logo/image

An Official Website of the United States Government

Compact Hydrogen Peroxide Sensor for Sterilization Cycle Monitoring

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2012 / SBIR
Agency Tracking Number:
R44EB013517
Solicitation Year:
2012
Solicitation Topic Code:
NIBIB
Solicitation Number:
PA10-050
Small Business Information
Physical Sciences Inc.
20 New England Business Center Andover, MA 01810-1077
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2012
Title: Compact Hydrogen Peroxide Sensor for Sterilization Cycle Monitoring
Agency: HHS
Contract: 4R44EB013517-02
Award Amount: $985,098.00
 

Abstract:

DESCRIPTION (provided by applicant): Improper or incomplete sterilization of manufacturing facilities is a major cause of pharmaceutical product recalls. The economic and societal impact of these recalls is significant and difficult to quantify. Many pharmaceutical companies use vapor phase hydrogen peroxide (VPHP) to decontaminate and sterilize production facilities, including barrier isolators. A reliable instrument with a large dynamic range and high sensitivity for monitoring VPHP during barrier isolator decontamination would be invaluable to manufacturers to improve product sterility assurance and quality. Physical Sciences Inc. (PSI) proposes to develop a commercial prototype sensor that will facilitate rapid and reliable development of decontaminationcycles, equipment qualification and continuous monitoring of barrier isolators, enabling significant improvements to sterility assurance, drug quality and availability. The instrument will measure VPHP and water vapor using tunable diode laser absorptionspectroscopy (TDLAS) with novel quantum cascade lasers and cavity enhanced spectroscopy. VPHP is a commonly used decontamination agent which must be carefully monitored to ensure sterility assurance and must be removed to very low levels prior to pharmaceutical filling operations due to its deleterious effects on pharmaceutical products. The sensor will be used to study vapor phase decontamination agent flow within an isolator and the effects of hydrogen peroxide destruction, adsorption and desorption for materials commonly used to fabricate isolators and in pharmaceutical fill/finish packaging operations. This Small Business Innovation Research Phase I / Phase II project addresses an immediate need for real-time measurement of trace amounts of VPHP in pharmaceutical filling and packaging systems. Barrier isolators are finding increasing use in the production and packaging of new biologic drug products. The instrument will enable production of a critical database of information for use in the pharmaceutical industry. The specific program innovation is the use of new quantum cascade laser technology with cavity enhanced spectroscopy to enable ultra-sensitive detection of critical decontamination parameters throughout the cycle and allow investigation of real-world fill/finish parameters (such as packaging material uptake of VPHP). Additional applications of the sensor include decontamination monitoring of lyophilizers and VPHP destruction of Meticillin-Resistant Staphylococcus Aureus (MRSA) contamination in hospital wards. No commercially available sensor can provide continuous VPHP measurements throughout the entire decontamination and purge cycles in manufacturing scale operations. The proposed sensor will provide this capability, allowing real-time process monitoring and control. This development targets the USFDA process analytical technology (PAT) initiative for building quality into pharmaceutical products, increasing the availability of critical drug products like vaccines and reducing the costs of prescription drug products.

Principal Investigator:

Krishnan Parameswaran
978-689-0003
parameswaran@psicorp.com

Business Contact:

Richard A. Sasso
978-689-0003
sasso@psicorp.com
Small Business Information at Submission:

PHYSICAL SCIENCES, INC
20 NEW ENGLAND BUSINESS CENTER ANDOVER, MA -

EIN/Tax ID: 104251709
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No