USA flag logo/image

An Official Website of the United States Government

Non-invasive neonatal respiration monitor

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2012 / STTR
Agency Tracking Number:
R41HD072901
Solicitation Year:
2012
Solicitation Topic Code:
NICHD
Solicitation Number:
HD12-193
Small Business Information
FLUOROMETRIX CORPORATION
24 TIMBER EDGE RD STOW, MA -
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2012
Title: Non-invasive neonatal respiration monitor
Agency: HHS
Contract: 1R41HD072901-01
Award Amount: $495,357.00
 

Abstract:

DESCRIPTION (provided by applicant): Preterm birth requires technologies for supporting immature organ systems on one hand while minimizing technology-induced injury on the other that may contribute to long-term adverse outcomes. Specific problems of thiskind are extremes in arterial partial pressure of oxygen and carbon dioxide. A variety of pathological conditions are known to result from both hypoxemia and hyperoxia. However, current understanding is that the range for acceptable paO2 is quite narrow.Similarly, hypocarbia or hypercarbia can result in brain or ocular pathology. The optimal range of paCO2 has not been established, but avoiding extremes is critical for survival. Thus, arterial blood gas (ABG) measurements are indispensable for respiratorymanagement in the neonatal intensive care unit (NICU). But because these require the withdrawal of blood, they can lead to complications such as infection, thrombus formation, bleeding, and pain. Furthermore, ABGs provide only intermittent information concerning dynamic changes in blood gases. To address some of these concerns, transcutaneous monitors for O2 (tcpO2) and CO2 (tcpCO2) using electrochemical sensors have been used. However, these electrodes have many disadvantages: (1) They suffer from calibration drift due to depletion of the electrolyte; (2) lack of sensitivity at low O2 due to consumption of O2 by the Clark electrode; (3) potential membrane failure; (4) use of adhesives to maintain direct skin contact; (5) possible burns from raising skin temperature to 43 C; (6) time-consuming due to large transcutaneous mass transfer resistance and equilibrium-based measurements. The goal of this project is to develop a combined tcpO2/tcpCO2 monitor for the neonate based on the optical sensing of O2 and CO2that is free from the drawbacks mentioned above. We propose to use highly sensitive noninvasive optical sensors in a unique design to achieve our objective. A collaborative team of scientists, engineers and clinicians has been assembled. Phase II will address the further clinical testing of the device. PUBLIC HEALTH RELEVANCE: Preterm birth requires technologies for supporting immature organ systems on one hand while minimizing technology-induced injury on the other that may contribute to long-term adverse outcomes. Specific problems of this kind are extremes in arterial partial pressure of oxygen and carbon dioxide. A variety of pathological conditions are known to result from both hypoxemia and hyperoxia. However, current methodologies involve arterial blood gas measurement (invasive, painful and carries risk of infection), or transcutaneous sensors that require adhesion to the skin (injury risk) and/or heating of the skin to achieve adequate gas diffusion (risk of burns). To address these issueswe plan to develop a novel trancutaneous sensor that is: (1) non-invasive/painless; (2) more accurate and much safer than current sensors; (3) easy to use by staff; (4) and can produce much faster results to follow the dynamic changes in blood gases for longer periods of time. By the end of this Phase I STTR project we plan to demonstrate proof of principle and prepare for larger scale Phase II testing in the neonatal intensive care unit.

Principal Investigator:

Xudong Ge
978-461-2468
xge1@umbc.edu

Business Contact:

Joseph E. Qualitx
978-461-2468
q@fluorometrix.com
Small Business Information at Submission:

FLUOROMETRIX CORPORATION
24 TIMBER EDGE RD STOW, MA -

EIN/Tax ID: 104349033
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
UNIVERSITY OF MARYLAND BALT CO CAMPUS
UNIVERSITY OF MARYLAND BALT CO CAMPUS
1000 HILLTOP CIRCLE
BALTIMORE, MD 21250-
Contact: