USA flag logo/image

An Official Website of the United States Government

Multiplex platform for point of care newborn screening of hyperbilirubinemia

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2012 / SBIR
Agency Tracking Number:
R43HD072853
Solicitation Year:
2012
Solicitation Topic Code:
NICHD
Solicitation Number:
HD12-192
Small Business Information
ADVANCED LIQUID LOGIC
615 Davis Dr., Suite 800 PO Box 14025 RESEARCH TRIANGLE PARK, NC -
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 1
Fiscal Year: 2012
Title: Multiplex platform for point of care newborn screening of hyperbilirubinemia
Agency: HHS
Contract: 1R43HD072853-01
Award Amount: $468,008.00
 

Abstract:

DESCRIPTION (provided by applicant): Jaundice is the most common condition that requires urgent medical attention in some newborns and is the result of elevation in circulating unconjugated bilirubin. The unbound unconjugated bilirubin can be specificallyneurotoxic and, if untreated, is associated with irreversible lifelong neurological damage. This condition is the most easily preventable cause of brain damage in otherwise healthy infants. Thus, severe neonatal hyperbilirubinemia has been nominated for inclusion on the uniform newborn screening panel in the US. Two main reasons dictate that the screening should be performed at the point of care. First, bilirubin is light-sensitive, requiring immediate sample analysis and therefore not compatible with the traditional dried blood spot newborn screening paradigm. Second, neonates with severe hyperbilirubinemia need to be treated urgently often prior to discharge. Newborn screening, as currently performed by collecting dried blood spots from infants and then sending them to a centralized laboratory for analysis, with turnaround times of at least 3 days is not suitable for universal bilirubin screening. Therefore, there is an immediate need to develop novel point of care technologies that will meet the AmericanAcademy of Pediatrics recommendation for bilirubin screening. Advanced Liquid Logic's digital microfluidic platform is a recognized innovative, low-cost, automated microdroplet-based liquid handling system that can be configured to address this challenge.The digital microfluidic technology enables miniaturization of assays and significantly reduces reagent and sample volumes, lowering not only the costs but also the neonatal sample volume requirements. A disposable lab-on- a-chip will be developed to assess an infant's risk for developing bilirubin-induced neurotoxicity at the point of care. The proposed platform will multiplex assays to measure total serum biliruibin, unbound bilirubin, albumin and carboxyhemoglobin levels to screen for risks related to severe neonatal hyperbilirubinemia, as well as the most frequent, known cause of kernicterus, glucose-6-phosphate (G6PD) dehydrogenase deficiency. In collaboration with Duke and Stanford University, work is ongoing to measure total serum bilirubin and G6PD deficiency on the digital microfluidic platform. In this project, assays will be developed for unbound bilirubin, albumin, and carboxyhemoglobin in the digital microfluidic format and results will be compared with those obtained using standard laboratory methods at Duke University. PUBLIC HEALTH RELEVANCE: Newborn screening is performed on every infant born in the US and there is a growing interest in increasing the number of conditions screened for. In this project, a digital microfluidic platformwill be developed to screen for hyperbilirubinemia, a condition that may result in irreversible neurological injuries if not treated. The proposed platform can be used at the point of care, resulting in rapid turnaround times necessary to prevent neurological impairment.

Principal Investigator:

Vamsee K. Pamula
919-287-9010
VPamula@Liquid-Logic.com

Business Contact:

Richard West
919-287-9010
rwest@liquid-logic.com
Small Business Information at Submission:

ADVANCED LIQUID LOGIC
615 Davis Dr., Suite 800 RESEARCH TRIANGLE PARK, NC -

EIN/Tax ID: 120170896
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No