USA flag logo/image

An Official Website of the United States Government

Home Gait Assessment System

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2013 / SBIR
Agency Tracking Number:
R44AG034698
Solicitation Year:
2013
Solicitation Topic Code:
NIA
Solicitation Number:
PA12-088
Small Business Information
EMPIRICAL TECHNOLOGIES CORPORATION
BOX 8175, 3046A BERKMAR DRIVE CHARLOTTESVILLE, VA 22906-8175
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2013
Title: Home Gait Assessment System
Agency: HHS
Contract: 2R44AG034698-02
Award Amount: $964,641.00
 

Abstract:

DESCRIPTION (provided by applicant): Falls among the elderly, one of the most common reasons requiring medical intervention and a contributing factor in 40% of nursing home admissions, are a major health problem. Several studies have identified quantifiable gait markers that appear to distinguish between elderly fallers and non-fallers. These studies have relied on data acquired in gait-laboratories. Extending gait assessment capability, and falls detection, into the home could provide valuable before-the-fact information on gait weakness evolution, which in turn could be used to assess the efficiency of counter measures. Current mobile gait analysis techniques are insufficient because they rely on compliance or are too intrusive. The development of a newgait assessment monitor is proposed. The device is passive and obtains gait data from miniature, shoe-worn, wireless devices, precluding the need to put on sensors, watches etc, walk on special surfaces, or be observed by cameras. This study's principal aim is to validate the device's performance through a comparison with accepted gait assessment techniques at the Motion Analysis and Motor Performance Laboratory at the University of Virginia Health System as well as a comparison study with accepted gait assessment tests at a local retirement community. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Falls among the elderly, one of the most common reasons requiring medical intervention and a contributing factor in 40% of nursing home admissions,are a major health problem. Several studies have identified quantifiable gait markers that appear to distinguish between elderly fallers and non-fallers. These studies have relied on data acquired in gait-laboratories. Extending gait assessment capability, and falls detection, into the home could provide valuable before-the-fact information on gait weakness evolution, which in turn could be used to assess the efficiency of counter measures. Current mobile gait analysis techniques are insufficient becausethey rely on compliance or are too intrusive. The development of a new gait assessment monitor is proposed. The device is passive and obtains gait data from miniature, shoe-worn, wireless devices, precluding the need to put on sensors, watches etc,. walkon special surfaces, or be observed by cameras. This study's principal aim is to validate the device's performance through a comparison with accepted gait assessment techniques at the Motion Analysis and Motor Performance Laboratory at the University of Virginia Health System as well as a comparison study with accepted gait assessment tests at a local retirement community.

Principal Investigator:

Martin C. Baruch
434-296-7000
mcbaruch@comcast.net

Business Contact:

David W. Gerdt
434-296-7000
davidetc@firstva.com
Small Business Information at Submission:

EMPIRICAL TECHNOLOGIES CORPORATION
BOX 8175, 3046A BERKMAR DRIVE CHARLOTTESVILLE, VA 22906-8175

EIN/Tax ID: 154177101
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No