USA flag logo/image

An Official Website of the United States Government

Micro-technology Enhanced Pediatric Lens Capsulotomy Device

Award Information

Agency:
Department of Health and Human Services
Branch:
N/A
Award ID:
Program Year/Program:
2013 / SBIR
Agency Tracking Number:
R44EY021023
Solicitation Year:
2013
Solicitation Topic Code:
NEI
Solicitation Number:
PA12-088
Small Business Information
MYNOSYS CELLULAR DEVICES, INC.
1061 EASTSHORE HWY. SUITE 201 ALBANY, CA 94710-
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2013
Title: Micro-technology Enhanced Pediatric Lens Capsulotomy Device
Agency: HHS
Contract: 2R44EY021023-02
Award Amount: $1,553,491.00
 

Abstract:

DESCRIPTION (provided by applicant): We propose an innovative microtechnology-enhanced surgical device that solves a significant therapeutic bottleneck in the treatment of lens cataract in children. As the leading cause of childhood blindness, lens cataract interferes with the optical performance of the eye and if untreated, results in lifelong deficits in visual perception. The first step in pediatric cataract surgery is technically the most challenging and involves the creation of a hole in the thin and highly elastic lens capsule to provide access for the subsequent removal of the diseased lens and if needed, the implantation of an artificial lens. Due to the unique biomechanical properties of the immature lens capsule, adult procedures for creating the capsulotomy opening, if applied to infants and young children, only have a 20% chance of success. Capsule tears hinder lens removal and affect the mechanical stability and performance of artificial lens implants. Currently, pediatric cataract surgeons mustmake do using devices with tissue chopping functions originally designed for non- cataract surgical uses, resulting in suboptimal pediatric lens capsulotomies. In order to simplify and automate pediatric lens capsulotomies and thus enhance the delivery ofvision care to young patients, we propose a disposable microtechnology-enhanced capsulotomy device to achieve consistent results across a range of surgical skills. The device is based on a proprietary method of tissue cutting in which a microfabricated cutting ring is housed within a collapsible elastomeric housing to produce precise capsulotomies on a sub-millisecond time scale. Our device is inserted through the standard 2.8 mm corneal incision and re-expands to produce a desired capsulotomy of 5 mm in diameter. In Phase I, we sucessfully demonstrated project feasibility by developing device protoypes that met specifications in terms of dimensions for intraocular use, compressibility, and capsule cutting. In the proposed Phase II studies, we will developa commercial version of the capsulotomy device, conduct engineering bench testing, and undertake surgical validation in an accepted rabbit model, with the goal of achieving product design freeze. In parallel, as a second aim, we will also develop a compacttable-top console to provide power, timing circuits, vacuum, diagnostics, and safety alerts for the casulotomy device. Results from this Phase II work will allow us to advance to device certification by good laboratory practice (GLP) accredited facilitiesas required for clinical trial initiation and ultimte FDA approval. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: This work seeks to develop a microtechnology-enhanced surgical instrument to aid in the treatment of childhood blindness due tolens cataract. Lens cataract is the leading cause of pediatric visual disability, and cataract removal restores sight and improves the quality of life for both patients and their families. The proposed device simplifies and automates a technically challenging surgical task in pediatric cataract surgery.

Principal Investigator:

Christopher Keller
510-323-3151
Keller@Mynosys.com

Business Contact:

Christopher G. Keller
510-323-3151
Keller@Mynosys.com
Small Business Information at Submission:

MYNOSYS CELLULAR DEVICES, INC.
1061 EASTSHORE HWY. SUITE 201 ALBANY, CA 94710-

EIN/Tax ID: 120339156
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No