USA flag logo/image

An Official Website of the United States Government

CHIP-INTEGRATED EHD PUMPED CRYOGENIC COOLING SYSTEM

Award Information

Agency:
Department of Defense
Branch:
Navy
Award ID:
50734
Program Year/Program:
2001 / STTR
Agency Tracking Number:
525030135
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
ATEC, Inc.
7100 Baltimore Avenue, Suite 204 College Park, MD -
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2001
Title: CHIP-INTEGRATED EHD PUMPED CRYOGENIC COOLING SYSTEM
Agency / Branch: DOD / NAVY
Contract: N00014-01-C-0196
Award Amount: $500,000.00
 

Abstract:

We propose to develop an efficient heat rejection unit for cryogenic cooling with ultra low parasitic thermal, mechanical, and electromagnetic noise for cooling filters and sensors at HTS conditions. The proposed device will incorporate active micro-scaleheat transfer surfaces, pump(s), and temperature sensors in a single package that will be directly attached to the heat source. EHD micro pumping is particularly suitable for this application due to the fact that no moving parts are used. Innovations inthe microstructural geometries are intended to create higher pumping action and heat dissipation rates per unit surface area of the electronic component. A major advantage of the proposed system is the ability to produce a pumped loop for cooling ofdistributed electronics with variable cooling load, while maintaining the advantage of low parasitic noise. During Phase I, we demonstrated the feasibility of fabrication and operation of the proposed system and determined the performance envelope of thissystem at room temperature. The results of this investigation will assist in the development of micro cooling devices capable of operating at cryogenic temperatures.BENEFITS: Heat rejection from HTS devices is a problem due to the high demand on thermalfluctuations and vibration. Our proposed device addresses a critical problem in a field in which the sensor and filter sensitivity and their dynamic range depend strongly on how well they are cooled. The proposed device will function as a thermal controlsystem for high power electronic systems or for sensitive devices or sensors requiring fine control of spatial cooling to minimize total system heat loads (such as in cryogenic HTS components). The micro cooling system will be a robust, lightweight devicethat provides thermal control for spacecraft, military and commercial applications containing multiple electronic component heat sources.

Principal Investigator:

John Lawler
3019313221

Business Contact:

John Lawler
3019313221
Small Business Information at Submission:

ATEC, INC.
11890 Old Baltimore Pike, Suit Beltsville, MD 20705

EIN/Tax ID:
DUNS: N/A
Number of Employees:
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
Research Institution Information:
UNIV. OF MARYLAND
Rm 2181, Bldg 088
College Park, MD 20742
Contact: Davinder K. Anand
Contact Phone: (301) 405-5294
RI Type: Nonprofit college or university