An Official Website of the United States Government

A VERY HIGH EFFECTIVENESS HEAT EXCHANGER FOR REVERSE BRAYTONCRYOCOOLERS

Award Information

Agency:
Department of Energy
Branch:
N/A
Award ID:
10835
Program Year/Program:
1990 / SBIR
Agency Tracking Number:
10835
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
Alabama Cryogenic Engineering, Inc.
2010F Franklin Street Huntsville, AL 35804
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 1990
Title: A VERY HIGH EFFECTIVENESS HEAT EXCHANGER FOR REVERSE BRAYTONCRYOCOOLERS
Agency: DOE
Contract: N/A
Award Amount: $500,000.00
 

Abstract:

THERE IS AN ACUTE NEED FOR VERY HIGH EFFICIENCY HEAT EXCHANGERS IN CRYOGENIC APPLICATIONS. THE GOAL OF PHASE I IS A HEAT EXCHANGER DESIGN WITH AN EFFECTIVENESS 0.99. THE HEAT EXCHANGER GEOMETRY IS A PERFORATED, PARALLELPLATE TYPE. THE DESIGN METHODOLOGY ENTAILS EXPLICIT CALCULATION OF HEAT TRANSFER RATES AND PRESSURE DROPS BY CONSIDERING LONGITUDINAL THERMAL CONDUCTION, BOUNDARY LAYER DEVELOPMENT, PROPERTIES OF TEMPERATURE FLUIDS AND MATERIALS,PLATE ALIGNMENT, AND PLATE SPACING. CONSIDERABLE EFFORT WILL BE DEVOTED TO DETERMINING THE PLATE FIN EFFECTIVENESS, AS THIS EFFECT CAN LIMIT SIGNIFICANTLY THE OVER-ALL HEAT TRANSFER RATE. A DESIGN PROGRAM WILL BE DEVELOPED THAT CALCULATES THE HEAT EXCHANGER PARAMETERS BASED ON CONSIDERATION OF THE LISTED EFFECTS.

Principal Investigator:

Dr John B Hendricks
Principal Investigator
2055368629

Business Contact:

Small Business Information at Submission:

Alabama Cryogenic Engineering
Po Box 2470 Huntsville, AL 35804

EIN/Tax ID:
DUNS: N/A
Number of Employees: N/A
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No