USA flag logo/image

An Official Website of the United States Government

Tissue-Equivalent Radiation Dosimeter-On-A-Chip

Award Information

Agency:
National Aeronautics and Space Administration
Branch:
N/A
Award ID:
83847
Program Year/Program:
2008 / SBIR
Agency Tracking Number:
066214
Solicitation Year:
N/A
Solicitation Topic Code:
N/A
Solicitation Number:
N/A
Small Business Information
Radiation Monitoring Devices, Inc.
44 Hunt Street Watertown, MA 02472-4699
View profile »
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No
 
Phase 2
Fiscal Year: 2008
Title: Tissue-Equivalent Radiation Dosimeter-On-A-Chip
Agency: NASA
Contract: NNJ08JA55C
Award Amount: $599,951.00
 

Abstract:

Available digital dosimeters are bulky and unable to provide real-time monitoring of dose for space radiation. The complexity of space-flight design requires reliable, fault-tolerant equipment capable of providing real-time dose readings during a mission, which is not feasible with the existing thermo-luminescent dosimeter (TLD) technology, especially during extravehicular activities (EVA). Real-time monitoring is important for low-Earth orbiting spacecraft and interplanetary space flight to alert the crew when Solar Particle Events (SPE) increase the particle flux of the spacecraft environment. The Phase-II project will design and fabricate a prototype Dosimeter-on-a-Chip (DoseChip) for personal dosimetry comprised of a tissue-equivalent scintillation crystal coupled to a solid-state photomultiplier (SSPM). The ubiquitous nature of CMOS technology provides a standardized development platform, and the ability to integrate the supporting electronics into a miniature, lightweight design. The DoseChip provides a tissue-equivalent response to the relevant energies and types of radiation for low-Earth orbit and interplanetary space flight to the moon or Mars and will be sensitive to the dose rates and particle fluxes of ambient Galactic Cosmic Rays (GCR) to the higher rates of major SPE. The DoseChip will complement the existing Crew Passive Dosimeters by providing real-time dosimetry and as an alarming monitor for SPE.

Principal Investigator:

James Christian
Principal Investigator
6176686800
JChristian@rmdinc.com

Business Contact:

Nancy Marshall
Business Official
6176686801
NMarshall@RMDInc.com
Small Business Information at Submission:

Radiation Monitoring Devices, Inc.
44 Hunt Street Watertown, MA 02472

EIN/Tax ID: 042546395
DUNS: N/A
Number of Employees:
Woman-Owned: No
Minority-Owned: No
HUBZone-Owned: No