You are here

Development of CMOS Based Large Format X-ray Detector for Protein Crystallography

Award Information
Agency: Department of Health and Human Services
Branch: National Institutes of Health
Contract: 2R44GM085937-02
Agency Tracking Number: GM085937
Amount: $1,697,000.00
Phase: Phase II
Program: SBIR
Solicitation Topic Code: NIGMS
Solicitation Number: PHS2010-2
Timeline
Solicitation Year: 2010
Award Year: 2010
Award Start Date (Proposal Award Date): N/A
Award End Date (Contract End Date): N/A
Small Business Information
RESEARCH DETECTORS, INC. 311 WEXFORD DR
LEMONT, IL -
United States
DUNS: 193321465
HUBZone Owned: No
Woman Owned: No
Socially and Economically Disadvantaged: No
Principal Investigator
 EDWIN WESTBROOK
 (630) 222-1005
 EDWESTBROOK@GMAIL.COM
Business Contact
 EDWIN WESTBROOK
Phone: (630) 222-1005
Email: ewestbrook@lbl.gov
Research Institution
N/A
Abstract

DESCRIPTION (provided by applicant): We propose to develop an inexpensive, yet very high quality detector system for protein crystallography, using Active Pixel Matrix CMOS (complementary metal-oxide-semiconductor) technology. We have based this effort on an existing CMOS imaging system for X rays, manufactured by Rad-icon Imaging Corporation. During Phase I of this proposed project, we increased the active area of the existing detector module 4-fold, by doubling its pixel size from 485m to 965m. Full-scale (50mm x 100mm) prototypes were fabricated and tested. We decreased its total noise by half, and we increased its readout precision from 12-bit (1 part in 4,096) to 14- bit (1 part in 16,384). Finally, we fabricated small (16pixel x16pixel) prototype devices whose readout was redesigned with 16-bit, correlated double sampling (CDS). We test these devices and verified that CDS reduces the readout noise by up to a factor of 6. In Phase II, we will fabricate full-sized sensors with correlated double sampling. We will also incorporate additional noise suppression technology, particularly multiple non-destructive readout. By fabricating the new sensors with multiple readout ports, we enable parallel readout, so we can read each pixel many (16) times in less than one second, thus improving the reliability of each measurement. These technical improvements will reduce noise sufficiently that we can implement 16-bit precision readout such that the noise is less than one part in 65,536 of the total range of the detector. We will then develop a complete detector system, incorporating 12 of these modules in a 2x6 array, covering an area of 20cm x 30cm. This system will be cooled to -600C, to reduce the noise even more. The X-ray detection systems we plan to bring to market will be technically very advanced relative to existing commercial units, yet they will cost about half as much. Our system will greatly improve the scientific effectiveness of structural molecular biology, and the cost effectiveness of their labor. PUBLIC HEALTH RELEVANCE: 1). Protein crystallography is a mature and important enabling technology for the biological sciences and in pharmaceutical development, for determining the structures of large biological molecules: proteins and nucleic acids. The present proposal would enhance the efficacy of protein crystallography, by improving the X-ray detector these scientists use in their home laboratory, to record the diffraction data from protein crystals they have grown. The detector we wish to develop is faster, higher-resolution, higher precision, and more efficient than the detectors now used by protein crystallographers, and it will be half the price.

* Information listed above is at the time of submission. *

US Flag An Official Website of the United States Government