Company: ENERTECHNIX, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 2
Abstract: …rated with automation technology developed by the Pacific Northwest National Laboratory (PNNL) to produce a self-contained portable personal exposure sampling unit and a bench-top assay unit. Enertechnix will be responsible for the aerosol sampling and microfluidic components… more
Company: Luna Innovations Incorporated Agency/Program/Year/Phase: DOD / SBIR / 2012 / 2
Abstract: Luna Innovations is developing the field-deployable Portable Analysis of Toxic H2O Samples (PATHOS) that utilizes whole cells as extremely sensitive biological detectors of water toxicants via two different metrics (colorimetric and impedance), resulting in increased reliability and sensitivity to a… more
Company: Giner, Inc. Agency/Program/Year/Phase: DOD / SBIR / 2012 / 1
Abstract: … oxidize a mixture of fuels. The cathode complexes facilitate direct electron transfer for oxygen reduction reaction. The configured system does not require exogenous power for fuel delivery, and demonstrates a simple structure and easy operation. This microfluidic… more
Company: IMMPORT THERAPEUTICS, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: DESCRIPTION (provided by applicant): We aim to develop a fully integrated microfluidic immunodiagnostic platform utilizing a novel air-liquid cavity acoustic transducer (ALCAT) technology pioneered in the lab of Dr Abe Lee. The diagnosis platform is basedon the well-established… more
Company: Gamma Dynamics LLC Agency/Program/Year/Phase: NSF / SBIR / 2012 / 2
Abstract: … year, while adding minimal cost to building infrastructure. The commercialization path for this technology is through the Advanced Flat Glass segment of the Flat Glass market. In addition, this program will enhance scientific innovation at the Ohio Center for Microfluidic… more
Company: LUCIGEN CORPORATION Agency/Program/Year/Phase: HHS / SBIR / 2012 / 2
Abstract: … disposable reagent cartridge. A key factor enabling this game changing technology is the development of a novel enzyme that converts RNA to DNA and isothermally amplifies it in minutes. These attributes have allowed the design of a device that does not use any microfluidics,… more
Company: Lynntech, Inc. Agency/Program/Year/Phase: EPA / SBIR / 2012 / 2
Abstract: … able to analyze a variety of both organic and metallic contaminants in environmental samples. A multiplicity of innovative components and designs for sample pre-concentration, separation, fluid transfer and detection were introduced, with emphasis on microfluidic… more
Company: NESHER TECHNOLOGIES, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: …. NTI recently achieved expansion from 2-color (2c) to 4-color (4c) ALEX, substantially expanding its multiplexing power. Furthermore, recent work by our consultants Profs. Stephen Quake and Shimon Weiss demonstrates successful merging of microfluidics-based sample… more
Company: NESHER TECHNOLOGIES, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: … power, and demonstrated diagnosticutility for ultrasensitive miRNA quantification at clinically relevant concentrations without amplification. Furthermore, recent work by our consultants Steve Quake and Shimon Weiss shows i) combination of microfluidics-based sample… more
Company: NetBio, Inc. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 2
Abstract: … SBIR goal is to develop a rapid, cost-effective, sensitive and specific Ct POC diagnostic system to increase early detection, inform appropriate treatment, reduce the rateof infections, and thereby reduce sequelae. In SBIR Phase I, we developed an initial microfluidic NAAT… more
Company: P2D, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: …e in treating sTBI-associated HICP onset. Our proposed SBIR research and commercialization program is to develop a blood and CSF POC neuromonitoring device to predict and identify sTBI patients who will experience delayed HICP onset later. The POC device is based on microfluidic… more
Company: SILOAM BIOSCIENCES Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: …, can work with low sample volumes are typically expensive and have limited sensitivity. Ultra-high sensitivity platforms are also expensive and typically require complex sample prep steps and large sample volumes. Siloam has developed a novel Optimiser microfluidic assay… more
Company: Southwest Sciences, Inc. Agency/Program/Year/Phase: DOE / SBIR / 2012 / 1
Abstract: DOEs efforts to monitor legacy sites for groundwater contamination would benefit from turn-key systems that can measure metal contaminant concentrations in situ. Southwest Sciences proposes to develop a micro-fluidic sensor for measuring heavy metals in groundwater by measuring… more
Company: TECHSHOT, INC. Agency/Program/Year/Phase: NASA / SBIR / 2012 / 2
Abstract: … flight qualified processing payloads to extract experiment samples via a needle-less septum and then allows transfer of those samples into a number of different on-orbit analytical devices, including such instrumentation as the Light Microscopy Module, the Microfluidic Flow… more
Company: TECHSHOT, INC. Agency/Program/Year/Phase: NASA / SBIR / 2012 / 1
Abstract: … in the LMM, which could lead to new advanced materials with exciting commercial potential. Capitalizing on Techshot's rapid progress with the LMM-DS, as well as the company's vast array of separations technologies and extensive experience with microfluidic systems… more
Company: Sunburst Sensors, LLC Agency/Program/Year/Phase: DOC / SBIR / 2012 / 1
Abstract: … design that can reliably measure both quantities with the required accuracy and precision. We will investigate two innovations that will significantly simplify and reduce the cost of our current sensors. First, we will combine the optics and flow cell using microfluidics… more
Company: Translume Agency/Program/Year/Phase: NASA / SBIR / 2012 / 1
Abstract: Translume, in collaboration with Dr. Joseph Needoba, Oregon Health and Science University, proposes to develop a microfluidic colorimetric sensor for the quantitative measurement of important inorganic nutrients in estuaries, coastal waters, and oceans. The technology will… more
Company: Wasatch Microfluidics, LLC Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: …vided by applicant): The goal of this Phase I SBIR project is to develop a device for automated array printing of lipids and membrane proteins onto submerged microtiter plate surfaces in a way that maintains their activity and function. Ourproprietary 3D microfluidic printing… more
Company: WAVE 80 BIOSCIENCES, INC. Agency/Program/Year/Phase: HHS / SBIR / 2012 / 1
Abstract: …evelopment in September 2009 by NIAIDfor use in differentiating between true infection and vaccine-induced seropositivity in future HIV vaccine trials and is now entering the verification and validation stage of development. The EOSCAPE-T1D will combine proprietary micro-fluidic… more
Company: Weinberg Medical Physics LLC Agency/Program/Year/Phase: DOE / SBIR / 2012 / 1
Abstract: … puts the USA at a disadvantage in developing exportable products. The proposed DOE project aims to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences constructing such devices, the proposed … more
Company: Physical Optics Corporation Agency/Program/Year/Phase: DOD / SBIR / 2012 / 1
Abstract: … concern due to their known toxic and carcinogenic effects. To address the Army"s need for a field-portable test to detect and quantify chlorinated organic compounds in water samples, Physical Optics Corporation (POC) proposes to develop a novel Microfluidics-Based… more
Company: Physical Optics Corporation Agency/Program/Year/Phase: DOD / SBIR / 2012 / 2
Abstract: ABSTRACT: In response to the Air Force need for a nutplate installation process that requires no preparation of the nutplate before installation, Physical Optics Corporation (POC) has developed a new Pull and Stick Nutplate Process (PASN) based on an innovative micro-fluid… more
Company: Intelligent Optical Systems Inc. Agency/Program/Year/Phase: NASA / SBIR / 2012 / 1
Abstract: …ise in lateral flow test strip (LFTS) assays by integrating an LFTS with a cell phone for the quantitative measurement of blood-based biomarkers. Our innovative and extremely cost-effective multi-analyte LFTS approach is imminently suited for space travel. All "… more
Company: Abeam Technologies Agency/Program/Year/Phase: DOD / STTR / 2012 / 2
Abstract: …, similar to the transition from electron tubes to integrated circuits in electronics. The spectrometer is an optical chip just a few millimeters in size; it can be implemented to detect any desired substance. The spectrometer can potentially be integrated with microfluidic… more
Company: GIGAGEN, INC. Agency/Program/Year/Phase: DOE / SBIR / 2012 / 1
Abstract: … has the potential to unlock the complexity inherent to cell populations. However, conventional techniques for cell isolation are very low-throughput. The goal of this DOE-SBIR grant proposal is to develop GigaGens patent-pending GigaLink microfluidic … more
Displaying 76 – 100 of 748 Awards
Narrow Your Search
By Agency
By Year
By Phase
By Program
By State
By Company Ownership
By Company
HELP FOR NARROW YOUR SEARCH

Search Options

There are several categories such as “By Agency”, “By Year”, “By State” etc. Select a checkbox within a category to refine your search results.

Each of your selections is listed in the “Narrow Search Filters” bar. You can uncheck these selections to remove them.


Search for Either Criteria

When you select multiple values within a category, the results will include values that match either of the selections. For example, selecting “2005” and “2007” in the “By Year” category will display results that include either 2005 OR 2007 in the results.


Narrowing the Search Results

You can refine your search results across categories. To narrow down your results, select multiple values across different categories. The results will only include values that match the selections across the categories. For example, selecting “2005” in the “By Year” category and “NASA” in the “By Agency” category will only display the results that contain both “2005” AND “NASA” in the results.