Company

Portfolio Data

Icon: back arrowBack to Company Search

Organic Robotics Corporation

Address

260 E Main St Ste 6364
Rochester, NY, 14604-2101
USA

UEI: CY4NGYFH3LF8

Number of Employees: 12

HUBZone Owned: No

Woman Owned: No

Socially and Economically Disadvantaged: No

SBIR/STTR Involvement

Year of first award: 2020

7

Phase I Awards

6

Phase II Awards

85.71%

Conversion Rate

$963,954

Phase I Dollars

$7,872,023

Phase II Dollars

$8,835,977

Total Awarded

Awards

Up to 10 of the most recent awards are being displayed. To view all of this company's awards, visit the Award Data search page.

Seal of the Agency: DOD

HAVOC-Wear Phase 2 Sequential

Amount: $1,999,879   Topic: A224-025

LLume proposes the development of an integrated physiological monitoring combat shirt using its proprietary Light Lace® fiberoptic sensor technology. This soft, stretchable sensing platform enables continuous, real-time monitoring of critical physiological metrics—respiration rate, ventilation, and VO?—without requiring direct skin contact, masks, or external chest straps. By embedding the sensors directly into the fabric of standard military uniforms, this system offers a frictionless, durable solution that aligns with Army modernization goals in human performance, health monitoring, and soldier survivability.The proposed effort builds on a successfully completed SBIR Phase II. This 24-month Sequential Phase II will focus on scaling sensor placement, refining embedded algorithms to support soldier-specific movements, optimizing the hardware packaging for rugged field conditions, and ensuring secure communication with Army data systems. The final deliverable will be a field-ready, wearable system capable of providing high-fidelity physiological data to commanders, medics, and researchers in both training and operational environments.This capability represents a significant advancement over existing wearables, which are typically bulky, require frequent manual interaction, or fail under real-world movement and environmental stress. By leveraging high-speed optical sensing and fabric-level integration, the LLume platform enables passive, reliable data capture under real combat and training conditions.The benefits extend beyond military applications. The same underlying technology is adaptable to the sports, occupational safety, and healthcare markets, where real-time respiratory and cardiovascular monitoring is increasingly in demand but limited by current wearable form factors. The LLume combat shirt project will demonstrate the feasibility, scalability, and mission value of fabric-integrated biometrics and set the stage for broader DoD deployment and dual-use commercialization.

Tagged as:

SBIR

Phase II

2025

DOW

ARMY

Seal of the Agency: DOD

K9 BEAM: Biometric Evaluation and Analysis for Mission-ready K9s

Amount: $249,034   Topic: A254-P001

Overview: Monitoring the health of military working dogs (MWD) is of paramount importance for several crucial reasons. These highly trained canines play an integral role in various military operations, including detection, search and rescue, and security tasks. Their unmatched senses and unwavering dedication make them invaluable assets to their human counterparts. Currently, the Department of Defense has no effective way to continuously monitor cardiorespiratory response in MWD. Although electronic health monitoring and wearables are trending and rapidly evolving, there still remains a lack of devices for health and wellness monitoring in both companion animals and MWDs. Some of these devices include Polar H10 Strap (for ECG monitoring) or VetMeasure (ECG and other vitals). However, these commercially available devices both come with constraints. For example, to use Polar H10, canines’ chest area has to be shaved and covered with electrically conductive gel. Further, Polar H10 only captures heart rate, and fails to measure other vitals such as respiratory rate, which is an indicator of fatigue. VetMeasure was designed to monitor canines after surgical operations, in a stationary setting. Although it captures multiple variables (heart rate, temperature, respiratory rate), the bulkiness and inaccuracy during exercise makes it unsuitable for usage during exercise or dynamic settings. Technical Abstract: Light Lace® is a soft, stretchable and thin fiberoptic sensor that can be integrated into chest straps or harnesses for measuring cardiorespiratory metrics. Light Lace® sensors are insensitive to electromagnetic interference and moisture and provide real time feedback on the biometrics of the user, without requiring any additional steps such as shaving the fur or applying electrode gel. 

Tagged as:

SBIR

Phase I

2025

DOW

ARMY

Seal of the Agency: DOD

LightLace GSuit TACFI

Amount: $979,986   Topic: AF21A-TCSO1

This project aims to integrate fiberoptic sensors into g-Trousers to measure muscle stiffness, blood flow, and respiration of pilots and trainees during AGSM. By embedding sensors directly into g-Trousers, we enhance pilots' endurance for longer missions, improve survival during aggressive maneuvers, and increase target engagement effectiveness. The project scope includes incorporating technological advancements, adding lower body sensors to g-Suits, and refining biometric and predictive analytics based on field testing and evaluations within the Department of Defense (DoD). During the Phase 2 award, ORC collaborated with the 711th Human Performance Wing to measure critical AGSM training metrics. Competitor solutions often fail in the cockpit due to electromagnetic interference, a problem mitigated by the fiber optic Light Lace® sensors, which maintain high signal quality unaffected by electromagnetic interference or static electricity. Initial tests involved integrating Light Lace® into chest, abdominal, and thigh straps to identify optimal sensor placements. The results suggested that direct integration into g-Suits or g-Trousers would simplify usage and promote broader adoption within the USAF.

Tagged as:

SBIR

Phase II

2024

DOW

USAF

Seal of the Agency: DOD

CANINE-SENSE: Comprehensive Assessment of Non-Invasive Metrics for Enhanced Service Efficiency

Amount: $109,955   Topic: AFX23E-TPCSO1

OVERVIEW Monitoring the health of military working dogs (MWD) is of paramount importance for several crucial reasons. These highly trained canines play an integral role in various military operations, including detection, search and rescue, and security tasks. Their unmatched senses and unwavering dedication make them invaluable assets to their human counterparts. Currently, the Department of Defense has no effective way to continuously monitor cardiorespiratory response in MWD. Although electronic health monitoring and wearables are trending and rapidly evolving, there still remains a lack of devices for health and wellness monitoring in both companion animals and MWDs. Some of these devices include Polar H10 Strap (for ECG monitoring) or VetMeasure (ECG and other vitals). However, these commercially available devices both come with constraints. For example, to use Polar H10, caninesÆ chest area has to be shaved and covered with electrically conductive gel. Further, Polar H10 only captures heart rate, and fails to measure other vitals such as respiratory rate, which is an indicator of fatigue. VetMeasure was designed to monitor canines after surgical operations, in a stationary setting. Although it captures multiple variables (heart rate, temperature, respiratory rate), the bulkiness and inaccuracy during exercise makes it unsuitable for usage during exercise or dynamic settings. Ś TECHNICAL ABSTRACT Light Lace« is a soft, stretchable and thin fiberoptic sensor that can be integrated into chest straps or harnesses for measuring cardiorespiratory metrics. Light Lace«Āsensors are insensitive to electromagnetic interference and moisture and provide real time feedback on the biometrics of the user, without requiring any additional steps such as shaving the fur or applying electrode gel.

Tagged as:

STTR

Phase I

2024

DOW

USAF

Seal of the Agency: DOD

Fiber Optic Tactical Apparel for Combat and Training

Amount: $1,249,990   Topic: AFX235-CSO1

For this project, we will be adapting our Light Lace® embedded wearables for airmen use cases. For this application, we are proposing to directly integrate Light Lace® into combat shirts to provide high adherence and an accurate biometric monitoring solution. Figure 7 shows the Light Lace® integrated combat shirt, the proposed solution for this effort. For illustration purposes, the “pod” is placed in the middle of the back. However, thanks to the fiberoptic sensing modality and no length constraints for the fibers, the pod can be placed anywhere on the body. If the user requires or prefers the pod to be on the front or towards the bottom of the shirt, for example, that can easily be done without requiring extra R&D or engineering effort. The illustration shows one fiberoptic sensor running straight from the neck to the waist for measuring posture. Depending on the posture of the user, the fiber will stretch a different amount and at different locations. ORC will then use this data to output real time posture metrics. The other sensors are placed around the chest for measuring biometrics, such as respiration rate, breathing pattern and heart rate. This measurement is achieved by measuring chest expansion as well as vibrations from pulse. Due to the high signal to noise ratio of ORC’s patented Light Lace® sensors, it can capture minute movements such as heart rate, as well as larger deformations like respiration, all through the same sensor. ORC has already tested hundreds of Light Lace® integrated textiles for measuring biometrics, and has achieved accurate results compared to the market leaders. Figure 8 shows a combat shirt iteration that is capable of measuring respiratory metrics. This combat shirt has Light Lace® fibers integrated into the chest area.  effort will focus on building a wearable sensing solution that can not only deliver real time cardiopulmonary information of the user, but also measure posture and quantity human response to unique operational environments, directly via combat shirts. To achieve this end goal, ORC will work with the end-user to define customer requirements, and build a seamless and comfortable wearable sensing solution. Different sensor placements will be examined and a mobile application or an API will be developed to visualize the metrics in real time. 

Tagged as:

SBIR

Phase II

2024

DOW

USAF

Seal of the Agency: DOD

Biomechanical Monitoring for Human Optimized Training and Operations

Amount: $74,988   Topic: AFX23D-TCSO1

Light Lace™ is a soft, stretchable and thin fiberoptic sensor that can be integrated into chest straps for measuring cardiorespiratory metrics and exposure to blast. Light Lace™ sensors are insensitive to electromagnetic interference and moisture and prov

Tagged as:

STTR

Phase I

2023

DOW

USAF

Seal of the Agency: DOD

Flight Lumbar and In-Seat High-Tech Wearable Ergonomic System (FLIGHTWISE): Cockpit Biometric and Posture Monitoring

Amount: $74,980   Topic: AFX235-CSO1

Light Lace™ is a soft, stretchable and thin fiberoptic sensor that can be integrated into chest straps for measuring cardiorespiratory metrics and exposure to blast. Light Lace™ sensors are insensitive to electromagnetic interference and moisture and prov

Tagged as:

SBIR

Phase I

2023

DOW

USAF

Seal of the Agency: DOD

Human Performance Monitoring Blast Environment

Amount: $149,360   Topic: A224-025

Redacted

Tagged as:

SBIR

Phase I

2023

DOW

ARMY

Seal of the Agency: DOD

Health Analysis from Vibrational Optical Characterization: HAVOC-Wear

Amount: $1,899,841   Topic: A224-025

Redacted.

Tagged as:

SBIR

Phase II

2023

DOW

ARMY

Seal of the Agency: DOD

Cockpit Monitoring of Pilot Muscle Tension, Heart Rate, and Respiration

Amount: $749,915   Topic: AF21A-TCSO1

ORC proposes to adapt our commercial Light Lace solution for use in high-G and anti-G training for Air Force pilots. Specifically, we aim to capitalize on the Light Lace measurement of muscle fatigue via fiber optic system measurement system by providing very low noise data during in centrifuge testing at the 711HPW. We aim to integrate the Light Lace system into the pilot’s flight equipment, both a pilot’s flight suit and anti-G suit, in order to aid the pilot in conserving energy exerted by straining and to only strain as hard as needed, which will lead to decreased fatigue, better physical fatigue resilience, and improved performance such as more pilots capable of 9 Gz maneuvers.

Tagged as:

STTR

Phase II

2022

DOW

USAF