You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Deployed First Responder Course of Action (COA) Evaluation and After Action Review (AAR) Tools
SBC: Aegis Technologies Group, LLC, The Topic: OSD10H07Many geospatial technologies and modeling techniques exist, especially for 3-D visualization of correlated layers of data. A gap remains in integrating the unstructured world of voice, chat, and free-form text communications to the more structured world
SBIR Phase I 2011 Department of DefenseDefense Health Agency -
Synthetic Tissue Trainer- Development of Realistic Tissue Elements for Surgical Task Training for Mangement of Combat Injuries
SBC: SIM-VIVO LLC Topic: OSD10H09The main outcome of this proposal will be the development of a new generation of task training manikins that will provide a realistic training platform for the instruction of invasive trauma resuscitation procedures (ITRP) such as peripheral IV insertion,
SBIR Phase I 2011 Department of DefenseDefense Health Agency -
Novel Vector Survaillance Trap for Flying Insects
SBC: TDA RESEARCH, INC. Topic: DHP12007Civilian and military organizations throughout the world perform surveillance to combat vector-borne disease. Of particular concern to the U.S. military are mosquito genera Anopheles, Aedes and Culex, which are important vectors for malaria, dengue and West Nile virus respectively, and sand fly genera Phlebotomus and Lutzomyia, both vectors for leishmaniasis. The trap most commonly used for by U.S ...
SBIR Phase I 2013 Department of DefenseDefense Health Agency -
Self Powered Biosensors
SBC: MAXENTRIC TECHNOLOGIES LLC Topic: DHP12010In response to the DHP 12-010 self powered biosensor solicitation, MaXentric proposes the VitalH system. Acknowledging the difficultly in creating a completely self-powered bio-sensor system that wirelessly transmits vital sign information, MaXentric has developed a solution which is extremely power efficient and minimally invasive. The VitalH garment continuously senses full ECG waveforms in a co ...
SBIR Phase I 2013 Department of DefenseDefense Health Agency -
A rapid and high-throughput microfluidic stem cell analyzer
SBC: CFD RESEARCH CORPORATION Topic: OSD11H14Current methods to discern the differentiation state of stem cells are time-consuming, labor-intensive, costly, invasive, and consequently, ill-suited for clinical applications. To overcome these limitations, we propose to develop a microfluidic stem cell analyzer for accurate, non-invasive identification of the cell differentiation state in conjunction with automated cell sorting at high-throughp ...
SBIR Phase II 2013 Department of DefenseDefense Health Agency -
Physics and Physiology Based Human Body Model of Blast Injury and Protection
SBC: CFD RESEARCH CORPORATION Topic: DHP13010The vast majority of injuries in recent military conflicts have been inflicted by improvised explosive devices (IEDs) causing brain, extremities and genital-urinary injuries. Advanced computational models of IED blast physics and human body injury biomech
SBIR Phase II 2015 Department of DefenseDefense Health Agency -
Novel Rewarming Technique for Cyropreserved Tissue
SBC: TDA RESEARCH, INC. Topic: DHP15014TDAs proposes to develop a novel RF heating process for rewarming cryogenically preserved tissues and organs. TDAs approach is to optimize the RF frequency and power, along with the chemical composition, size and morphology of infused nanoparticles so that they heat tissue samples rapidly and uniformly. In this manner, the cryoprotectant solutions pass from the vitrified state to the liquid stat ...
SBIR Phase I 2015 Department of DefenseDefense Health Agency -
Systems Biology Based Tools for Modeling Platelet Storage Lesion for Optimal Blood Transfusions
SBC: CFD RESEARCH CORPORATION Topic: DHP15011Trauma is the leading cause of death in civilian and military environments and acute hemorrhage contributes to a large portion of these fatalities. Recent experience from Iraq and Afghanistan has demonstrated the crucial role of blood products in the care of critically injured soldiers. Unlike plasma and red blood cells, which can be cold stored for longer time periods, platelets can be safely sto ...
SBIR Phase I 2015 Department of DefenseDefense Health Agency -
Inexpensive, Small, Biocompatible, Multi-Analyte, Voltammetric Blood Sensors Based on Functionalized Microporous Membranes, with, Impervious
SBC: Ashwin-Ushas Corporation Topic: DHP15012Traumatic hemorrhage is associated with the development of trauma induced coagulopathy, as well as a number of responses including an inflammatory response, endothelial dysfunction, and others.These pathophysiologic reactions develop and progress rapidly, and result in increased mortality and morbidity.In order to provide effective treatment under these rapid and dynamic conditions, it is imperati ...
SBIR Phase I 2015 Department of DefenseDefense Health Agency -
A rapid and high-throughput microfluidic stem cell analyzer
SBC: CFD RESEARCH CORPORATION Topic: OSD11H14Current methods for stem cell isolation are time-consuming, costly, and labor-intensive, and ill-suited for point of care applications. To overcome these limitations, we propose to develop and demonstrate a high-throughput, non-invasive, microfluidic stem cell analyzer to enable a rapid isolation of high-quality stem cell products from clinically relevant samples. Our technology enables significan ...
SBIR Phase II 2015 Department of DefenseDefense Health Agency