Advanced LWIR Hyperspectral System for On-the-Move Standoff Detection of Liquid Contaminants on Surfaces
SBC: PHYSICAL SCIENCES INC. Topic: CBD12104Physical Sciences Inc. (PSI) proposes to utilize an innovative LWIR hyperspectral technology coupled with advanced data processing algorithms for non-contact, passive standoff detection of liquid contaminants on surfaces. The technology will address the US Army"s need for fast, passive, on-the-move, non-contact detection of ground contamination during reconnaissance missions. The Phase I effort wi ...
SBIR Phase I 2012 Department of DefenseOffice for Chemical and Biological Defense -
Facial Signature Reduction
SBC: Bambu Vault LLC Topic: SOCOM12004Reducing the personal signature of the warfighter, while simultaneously allowing him to"see, breathe and hear"is critical to mission success. Methods of concealment that are suitable for the body do not adequately mask the face without hindering the ability to"see, breathe and hear". To address the need for reducing signature in the Visible and NIR/SWIR region Performance Indicator, LLC (PI) pro ...
SBIR Phase I 2012 Department of DefenseSpecial Operations Command -
Rapid, Quantitative Biological Indicator System with Bacillus thuringiensis Al Hakam Spores(1001-810)
SBC: TRITON SYSTEMS, INC. Topic: CBD11101Biological agents pose high threats, because they are invisible, odorless and a relatively small amount can infect a large population when released in a densely populated area. For the same reasons, assuring safety after cleaning decontaminated sites can be challenging. Currently available technologies require considerable labor, and results typically cannot be obtained before 24 V 48 hours up to ...
SBIR Phase II 2012 Department of DefenseOffice for Chemical and Biological Defense -
Clean, Green, ChemBio Defense/Fire Retardant Process Using Nanotechnology
SBC: Aqua Resources Corporation Topic: SOCOM10007NanoPlatelets (NPs) created of metal hydroxides present entirely new and previously unknown set of morphologes/properties and are a virtually new frontier and unstudied field of Material Science and may be leveraged into many of todays DoD and Comercial Technical Challenges and applications. Case in point is SOCOM's Defense Mitigation and Decontamination of military aircraft and equipment and ...
SBIR Phase II 2012 Department of DefenseSpecial Operations Command -
Small Integrated HFI Sensor for the AVR-2B
SBC: SOLID STATE SCIENTIFIC CORPORATION Topic: SOCOM11001"SSSC is pleased to propose the development and delivery of a Hostile Fire Indication Sensor (HFIS) based on the Phase I design concept. The resulting system will limit the number of circuit card assemblies to two: one for the short wave infrared (SWIR)
SBIR Phase II 2012 Department of DefenseSpecial Operations Command -
GENERALIZED MODELING OF CONDENSATION FOR REACTOR APPLICATION
SBC: CREARE LLC Topic: N/AN/A
SBIR Phase I 1985 Nuclear Regulatory Commission -
DEVELOPMENT OF A SAFE STOPPING-DISTANCE DETECTOR
SBC: Ssdd Research Corp Topic: N/AN/A
SBIR Phase I 1985 Department of Transportation -
HAZARDOUS MATERIAL IDENTIFICATION IN NORMAL TRANSPORT AND INACCIDENTS USING ELECTRONIC REMOTE CHEMICAL IDENTIFICATION SYSTEM (ERCIS)
SBC: Technology & Management System Topic: N/AN/A
SBIR Phase I 1985 Department of Transportation -
EXPERT SYSTEMS APPLICATIONS FOR AIR TRAFFIC CONTROL: A FEASIBILITY ANALYSIS
SBC: UFA, INC. Topic: N/AN/A
SBIR Phase I 1985 Department of Transportation