You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY20 is not expected to be complete until September, 2021.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

  1. Wearable shear-wave tensiometry for tracking tendon load during dynamic movement

    SBC: Design Concepts, Incorporated            Topic: NIAMS

    Project Summary The goal of this project is to commercialize a wireless, wearable system to estimate the tension in superficial tendons throughout the limbs during dynamic movements. Tendon tension provides an estimate of muscle force, which is important information for understanding biomechanical behavior in all types of movement. Understanding muscle-tendon function inside the body is especially ...

    STTR Phase II 2020 Department of Health and Human ServicesNational Institutes of Health
  2. Restimulating memory T cell responses in elderly by a novel, live influenza vaccine

    SBC: Flugen, Inc.            Topic: NIAID

    Respiratory infections with influenza viruses cause severe morbidity and mortality in humans and animals worldwideImportantlyin humansthe majority of morbidity and mortality following flu infection is seen in older individualsrtyears oldYetclear understanding of how aging impacts on innate immune responsesand how to improve vaccine design in this age group is lackingRestimulating preexisting memor ...

    STTR Phase II 2017 Department of Health and Human ServicesNational Institutes of Health
  3. Liquid Crystal-based Sensors for Detection of Airborne Toxic Chemicals for Integration with Unmanned Robotic Systems

    SBC: Platypus Technologies, LLC            Topic: A13AT004

    Platypus will leverage its scientific gains in the advancement of liquid crystal-based (LC) sensors to develop light weight, accurate, and instantaneous multi-target LC gas sensor systems with telemetry and low power consumption for retrofit or OEM integration onto unmanned vehicles (UMVs). We will also develop a computational design guide for the rapid production and deployment of LC sensors for ...

    STTR Phase II 2017 Department of DefenseArmy
  4. Mutation Enriched Targeted Re Sequencing

    SBC: TRANSGENOMIC, INC.            Topic: 103

    DESCRIPTION provided by applicant Low level tumor associated somatic DNA mutations can have profound implications for development of metastasis prognosis choice of treatment follow up or early cancer detection Unless they are effectively detected these low level mutations can misinform patient management decisions or become missed opportunities for personalized medicine Widely used tech ...

    STTR Phase II 2016 Department of Health and Human ServicesNational Institutes of Health
  5. High-Power, Monolithic THz Sources via Difference Frequency Generation in Phase-Locked Arrays of Quantum Cascade Lasers

    SBC: INTRABAND, LLC            Topic: A15AT003

    The technical objectives of this proposal are: 1) Fabricate and test ridge-guide, quantum-cascade-laser (QCL) devices employing a broad-gain-spectrum active-region design and suitable for incorporation in the designed high-index-contrast (HC) photonic-crystal (PC) THz, difference-frequency-generation (DFG) QCLs ; 2) Fabricate and test large-aperture HC-PC QCL devices suitable for THz generation vi ...

    STTR Phase II 2016 Department of DefenseArmy
  6. Neuroimaging tools for presurgical brain mapping

    SBC: PRISM CLINICAL IMAGING, INC.            Topic: 102

    DESCRIPTION provided by applicant The goal of this project is to develop functional magnetic resonance imaging fMRI tools to assist the diagnosis and treatment of human patients with a brain tumor or other operable pathology The specific focus of this proposal is to produce a practical clinic ready suite of MR imaging methods analyses and display tools to solve the number one impediment to ...

    STTR Phase II 2015 Department of Health and Human ServicesNational Institutes of Health
  7. IMPROVING THE TREATMENT OF CONTAMINATED AQUIFERS BYDEVELOPING DIRECT-PUSH OXIDANT CANDLES WITH PNEUMATIC CIRCULATORS

    SBC: AirLIft Environmental LLC            Topic: NIEHS

    DESCRIPTION provided by applicant Clean water is one of the most basic societal needs in the world Few situations incite more public outcry than when a community learns that their drinking water has been tainted Two of the biggest threats to groundwater quality in the U S are contamination from either chlorinated solvents or petroleum Left unattended the size and scope of the problems asso ...

    STTR Phase II 2015 Department of Health and Human ServicesNational Institutes of Health
  8. IMMEDIATE FIT USING INNOVATIVE TECHNOLOGY TRANSTIBIAL PROSTHESIS

    SBC: IFIT PROSTHETICS, LLC            Topic: NIA

    DESCRIPTION provided by applicant The goal of iFIT Prosthetics LLC r and its founder was to create and commercialize a modular immediate fit fully adjustable transtibial prosthesis system suitable for mass production using high strength polymer materials that are injection molded at a fraction of the cost of conventionally made prostheses This goal was achieved and now the aims of this P ...

    STTR Phase II 2015 Department of Health and Human ServicesNational Institutes of Health
  9. Liquid Crystal-based Sensors for Detection of Airborne Toxic Chemicals for Integration with Unmanned Robotic Systems

    SBC: Platypus Technologies, LLC            Topic: A13AT004

    In Phase I we successfully reached all goals and milestones in developing liquid crystal sensors that detected 100 ppb of each of four target gases (DMMP, hydrogen sulfide, nitrogen dioxide and ammonia) within 60 seconds. In Phase II, we propose to expand this detection capability to a total of seven gases, adding volatile organic compounds, chlorine and half-mustard to the set. We then propose ...

    STTR Phase II 2014 Department of DefenseArmy
  10. RADIOGRAPHIC CONTRAST TO DIFFERENTIATE CAVITATED FROM NON-CAVITATED DENTAL CARIES

    SBC: FIREFLY HEALTH INNOVATIONS NE, INC.            Topic: NIDCR

    DESCRIPTION provided by applicant This project aims to improve the accuracy of tests for early tooth decay dental caries specifically for interproximal surfaces where the posterior teeth abut one another In these regions there is no physical space to visually inspect or probe for caries Instead dentists rely on bitewing X rays BWs But dentists cannot tell whether lucencies observed ...

    STTR Phase II 2014 Department of Health and Human ServicesNational Institutes of Health
US Flag An Official Website of the United States Government