You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY20 is not expected to be complete until September, 2021.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

  1. Multimode Organic Scintillators for Neutron/Gamma Detection

    SBC: Radiation Monitoring Devices, Inc.            Topic: DTRA19B003

    There is significant interest in multi-functional materials enabling gamma-ray spectroscopy, neutron/gamma pulse shape discrimination (PSD), ultra-fast response, and time-of-flight (TOF) neutron detection. These materials would be used in a variety of mission scenarios for the localization and monitoring of special nuclear materials. Commercial inorganic scintillators offer some of these character ...

    STTR Phase I 2020 Department of DefenseDefense Threat Reduction Agency
  2. Discrete 3-D Electronics for Mobile Radiation Detection Systems

    SBC: Radiation Detection Technologies, Inc.            Topic: DTRA18B002

    Phase II will utilize knowledge gained from phase I work to develop and execute a manufacturing process suitable for producing quantities of 3-D printed discrete circuits for radiation detection systems.  The goal is to support mobile radiation detection system requirements for high voltage, analog amplification, and MCA functionality to produce differential pulse height spectra in time sequence. ...

    STTR Phase II 2020 Department of DefenseDefense Threat Reduction Agency
  3. Mixed Elpasolite Scintillators

    SBC: Radiation Monitoring Devices, Inc.            Topic: DTRA18B003

    The goal of this program is to develop the mixed elpasolite scintillators in order to achieve an energy resolution of  (≤ 2.5% (approaching 2%) at 662 keV for crystal sizes of up to 2 inch by 2 inch.  In this project we will investigate compositional changes in selected mixed-elpasolite(s) in order to achieve very high energy resolution.  By incorporating 6Li, neutron detection will also be t ...

    STTR Phase II 2020 Department of DefenseDefense Threat Reduction Agency
  4. High Energy Resolution Mixed-Halide Elpasolite Scintillators for Next Generation RIID

    SBC: CapeSym, Inc            Topic: DTRA18B003

    The ability to discriminate between threatening and benign sources depends on the sensitivity, accuracy, and identification speed of the detection equipment. High energy resolution of the radionuclide sensor is necessary to decrease the likelihood of false identification. However, few scintillators achieve better than 3% energy resolution at 662 keV, and none exceed 2.5%. The goal of this effort i ...

    STTR Phase II 2020 Department of DefenseDefense Threat Reduction Agency
  5. Compact Laser Drivers for Photoconductive Semiconductor Switches (16-RD-863)

    SBC: UES, Inc.            Topic: DTRA16A004

    Compact Electromagnetic Pulse Module (EMP) capable of being arranged in series-parallel planar or cylindrical arrays is needed to simulate nuclear weapon effects. High gain optically triggered photoconductive semiconductor switches (PCSS) based on Gallium arsenide (GaAs) with low timing jitter enables the development of planar or phased arrays of modular EMP or High Power Microwave (HPM) sources. ...

    STTR Phase I 2017 Department of DefenseDefense Threat Reduction Agency
  6. Portable System with Li Foil MWPC Neutron Detectors

    SBC: Radiation Detection Technologies, Inc.            Topic: DTRA14B005

    At the completion of the research and development effort a Li-foil multi-wire proportional counter (MWPC) neutron detector with more than 625-cm2 of active area will be included in a portable radiation detection system. The system is expected to outperform the standards set by the ANSI N42.53 standards, and gamma-ray rejection ratio (GRR) of 1.0x10-8 or better. A gamma-ray spectrometer for isotope ...

    STTR Phase II 2017 Department of DefenseDefense Threat Reduction Agency
  7. Microscale Detector Materials for Covert, Ubiquitous Radiation Detector

    SBC: Radiation Monitoring Devices, Inc.            Topic: DTRA14B004

    The proliferation of nuclear and radiological weapons of mass destruction is a serious threat in the world today. The goal of this proposal is to develop a new, very low cost radiation detection technology that will be useful for detection and for surveillance of individuals who have been near radioactive materials. The technology can also be used for dosimetry, and will provide the technology for ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency
  8. Portable System with Li Foil MWPC Neutron Detectors

    SBC: Radiation Detection Technologies, Inc.            Topic: DTRA14B005

    At the completion of the research and development effort a Li foil multi-wire proportional counter (MWPC) neutron detector with more than 625 cm^2 of active area will be included in a portable radiation detection system. The system is expected to have an intrinsic thermal neutron detection efficiency of 55% or greater and gamma-ray rejection ratio (GRR) of 1.0x10^-8 or better. A gamma-ray spectrom ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency
  9. Large area, high efficiency, extremely light-weight portable neutron Detector

    SBC: Triton Systems, Inc.            Topic: DTRA14B005

    A drop-in 3He-tube replacement technology for thermal neutron detection does not exist today. It is critical for homeland security and nuclear safeguards applications. In this program, Triton Systems proposes to develop a light-weight, large-area, high efficiency portable neutron detector for passive interrogation using an innovative gas detector structure. The resulting 3He-free thermal neutron d ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency
US Flag An Official Website of the United States Government