You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY20 is not expected to be complete until September, 2021.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

  1. Acoustically/Vibrationally Enhanced High Frequency Electromagnetic Detector for Buried Landmines

    SBC: AKELA INC            Topic: A16AT004

    Laboratory investigations have suggested that acoustically or vibrationally inducing motion in buried targets can aid in improving target detectability through a characteristic response related to differential target motion. This gain is realized by adding an additional degree of freedom, modulation due to motion in the GPR return signal, to use as a discriminating feature. The AKELA team is propo ...

    STTR Phase I 2016 Department of DefenseArmy
  2. Advanced Printed Circuit Board Design Methods for Compact Optical Transceiver

    SBC: ATTOLLO ENGINEERING, LLC            Topic: A15AT001

    As the warfighter is increasingly using more highly integrated instruments, e.g. a laser rangefinder (LRF) combined with a laser designator and an imager, the need to decrease the size of these components becomes more important.Compact small munition applications of rangefinders particularly place an emphasis on size of the optical front end.In order to make the transceiver more compact, special a ...

    STTR Phase II 2017 Department of DefenseArmy
  3. An Ultra-Compact Low-Power THz Radio SoC with On-Chip Antenna and Energy Harvesting

    SBC: Digital Analog Integration, Inc.            Topic: A15AT005

    There is an unmet demand for ultra-low-power, ultra-compact and low-cost radios to address emerging sensing and communication needs for military and commercial applications such as IoT/IoE. To overcome the limitations in existing bulky and power hungry radios, we propose a disruptive solution by integration of a nano-scaled THz transceiver, on-chip antenna, and energy harvesting circuits in a form ...

    STTR Phase II 2016 Department of DefenseArmy
  4. Bioaerosol Detector Wide Area Network

    SBC: Arete Associates            Topic: A17AT020

    Historically, the monitoring and detection of biological threats has been carried out via the deployment of high sensitivity / high complexity monitoring nodes to insure high probability of detection and low false alarm rate. Unfortunately, this detection strategy has inherent limits with respect to coverage and response due to its high deployment/support costs, mandating a new approach to environ ...

    STTR Phase I 2017 Department of DefenseArmy
  5. Biofidelic Rat Testing Device (RTD) to Measure Blast Exposure and Loadings for TBI

    SBC: CFD Research Corporation            Topic: A17AT022

    The overall objective of this project (Phase I, II, and III) is to develop, fabricate, and test a novel biofidelic rat surrogate for the validation of primary blast loading conditions for mild traumatic brain injury (mTBI). The CFDRC/NJIT team will use extensive knowledge of blast loading characteristics and TBI studies coupled with past/ongoing efforts designing and testing a rat surrogate. In P ...

    STTR Phase I 2017 Department of DefenseArmy
  6. Biosensor for Detection of Synthetic Cannabinoids

    SBC: NANOCOMPOSIX, INC.            Topic: A17AT014

    Recreational drug use by military personnel can impact soldier preparedness and performance especially in difficult and demanding environments. One challenge for monitoring illicit drug use is that current tests rely on the identification of specific chemical structures. Small variants in the chemistry of a drug can evade detection. In this Phase I SBIR, we will develop a lateral flow test that ...

    STTR Phase I 2017 Department of DefenseArmy
  7. Developing a Clostridium molecular toolkit for bioconversion of food waste

    SBC: SYNVITROBIO, INC.            Topic: A17AT011

    Waste generation at forward bases creates significant challenges; its disposal presents an economic cost with no direct benefit and its accumulation or burning is a health hazard. The bioconversion of waste into useful compounds could save thousands annually for every soldier and tens of millions in capital expenditure. However, widespread adoption is impeded by low conversion efficiency. We propo ...

    STTR Phase I 2017 Department of DefenseArmy
  8. Development of powder bed printing (3DP) for rapid and flexible fabrication of energetic material payloads and munitions

    SBC: MAKEL ENGINEERING, INC.            Topic: DTRA16A001

    This program will demonstrate how additive manufacturing technologies can be used with reactive and high energy materials to create rapid and flexible fabrication of payload and munitions. Our primary approach to this problem will be to use powder bed binder printing techniques to print reactive structures. The anticipated feedstock will consist of composite particles containing all reactant spe ...

    STTR Phase I 2016 Department of DefenseDefense Threat Reduction Agency
  9. Dismounted Soldier Positioning, Navigation and Timing (PNT) System Initialization

    SBC: Integrated Solutions For Systems, Inc.            Topic: A17AT017

    Integrated Solutions for Systems, Inc. (IS4S) and teammate Auburn University (AU) propose to develop a PNT initialization system for dismounted soldiers. The proposed system will enhance warfighters ability to operate immediately in a GPS denied environments once their mission begins and has wide commercialization potential outside of DoD. In Phase I, the feasibility and expected benefits of inte ...

    STTR Phase I 2017 Department of DefenseArmy
  10. 3D Tomographic Scanning Microwave Microscopy with Nanometer Resolution

    SBC: Alcatera Inc.            Topic: A17AT008

    Near-Field Scanning Microwave Microscopy (SMM) is a technique relying on a raster scan of a microwave probe across a sample surface, while measuring its reflected microwave signal. The existing technologies are limited to the surface analysis, and are not compatible with liquid environment. These limitations are addressed by the proposed wideband 3D tomography SMM with sub-surface analysis capabil ...

    STTR Phase I 2017 Department of DefenseArmy
US Flag An Official Website of the United States Government