  1. Retrofittable and Transparent Super-Insulator for Single-Pane Windows

    SBC: NANOSD, INC.            Topic: DEFOA0001429

    NanoSD, Inc. with its partners will develop a transparent, nanostructured thermally insulating film that can be applied to existing single-pane windows to reduce heat loss. To produce the nanostructured film, the team will create hollow ceramic or polymer nanobubbles and consolidate them into a dense lattice structure using heat and compression. Because it is mostly air, the resulting nanobubble s ...

    STTR Phase II 2016 Department of EnergyARPA-E
  2. Infectious Disease Diagnostics and Differentiation of Viral vs. Bacterial Infections for Point of Care Applications

    SBC: GENECAPTURE, INC.            Topic: CBD15C001

    The modern warfighter faces the constant threat of endemic infections, multi-drug resistant bacteria and Biological Warfare Agents. In order to provide accurate front-line treatment that will curtail the overuse of antibiotics, a rapid and robust molecula

    STTR Phase I 2016 Department of DefenseOffice for Chemical and Biological Defense
  3. Detecting Substandard, Nonconforming, Improperly Processed and Counterfeit Materiel

    SBC: Ocean Bay Information and Systems Management, LLC            Topic: DLA15C001

    "Micro-calorimetry is a Nondestructive Test (NDT) capable of detecting heat characteristics that could identify improperly processed, counterfeit, substandard, nonconforming or fake raw material prior to materials introduction into end-product production cycles. Current calorimetric technology is an extremely sensitive, expensive and time consuming process, utilizing an adiabatic or semi-adiabat ...

    STTR Phase I 2016 Department of DefenseDefense Logistics Agency
  4. Using Magnetic Levitation for Non-Destructive Detection of Defective and Counterfeit Materiel

    SBC: Nano Terra, Inc.            Topic: DLA15C001

    The introduction of substandard or counterfeit materials into the DoD supply chain can have extremely expensive, and potentially life threatening, consequences. Current techniques used to detect nonconforming materiel can be destructive (e.g., manual sectioning and inspection of a part), time consuming and expensive (e.g., micro-computed tomography, ultrasound), or provide only limited informatio ...

    STTR Phase I 2016 Department of DefenseDefense Logistics Agency
  5. Spray-based visual indicator of opioids for the rapid and effective decontamination of large areas

    SBC: TRITON SYSTEMS, INC.            Topic: CBD20AT001

    Triton Systems, Inc. will collaborate with The University of Massachusetts Lowell to develop a spray-based technology for the rapid, visual identification of opioids, turning contaminated areas from nondescript white powders to a brightly colored spots for easy recognition with the naked eye. The technology leverages molecular recognition units that bind strongly and specifically to a variety of o ...

    STTR Phase I 2021 Department of DefenseOffice for Chemical and Biological Defense
  6. Eye-readable Solution-based Dye Displacement Probe for Large-area Detection of Opioids

    SBC: INTELLIGENT OPTICAL SYSTEMS, INC.            Topic: CBD20AT001

    Intelligent Optical Systems, Inc., in collaboration with Bowling Green State University, proposes to develop a field-rugged, eye-readable indicating spray solution that can immediately detect synthetic opioids over a large area of contamination (i.e., military vehicles, individual protective equipment, clandestine labs, etc.). The proposed chemosensor in a spray solution format will detect multipl ...

    STTR Phase I 2021 Department of DefenseOffice for Chemical and Biological Defense
  7. Opioid Indicator Spray for Complex Surfaces

    SBC: Clear Scientific, LLC            Topic: CBD20AT001

    Opioids, especially synthetic opioids, are a constant threat to the safety of civilian first responders; there are now serious concerns about their use in modern chemical warfare. Fentanyl and its many analogues (carfentanil, remifentanil, lofentanil, mefentanil, sufentanil, etc.) are extremely hazardous—if ingested or inhaled, many synthetic opioids cause lethal intoxication with only a few gra ...

    STTR Phase I 2021 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government