You are here
Award Data
The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.
Download all SBIR.gov award data either with award abstracts (290MB)
or without award abstracts (65MB).
A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.
The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.
-
Smart Femtosecond Fiber Laser Wound Healing System
SBC: POLARONYX INC Topic: DHP15B002Based on our success in developing the world first commercial high energy femtosecond fiber laser system and our leading proprietary technology development in ultrashort pulsed fiber laser material processing, PolarOnyx proposes, for the first time, a compact high energy fiber laser based smart wound healing tool to meet with the requirement of this DHP solicitation. It includes a high energy fs f ...
STTR Phase I 2016 Department of DefenseDefense Health Agency -
Data Driven Intent Recognition Framework
SBC: OTHER LAB, INC. Topic: NSF13599A critical aspect of exoskeleton control that has to date introduced a performance limitation is the ability of the exoskeleton to recognize the intent of the operator so it can apply assistance to their desired motion. This intent recognition effort is typically solved using ad-hoc methods where subject matter experts make design decisions and tune transitions to identify intended maneuvers as re ...
STTR Phase II 2016 Department of DefenseSpecial Operations Command -
Detecting Substandard, Nonconforming, Improperly Processed and Counterfeit Materiel
SBC: Ocean Bay Information and Systems Management, LLC Topic: DLA15C001"Micro-calorimetry is a Nondestructive Test (NDT) capable of detecting heat characteristics that could identify improperly processed, counterfeit, substandard, nonconforming or fake raw material prior to materials introduction into end-product production cycles. Current calorimetric technology is an extremely sensitive, expensive and time consuming process, utilizing an adiabatic or semi-adiabat ...
STTR Phase I 2016 Department of DefenseDefense Logistics Agency -
Using Magnetic Levitation for Non-Destructive Detection of Defective and Counterfeit Materiel
SBC: Nano Terra, Inc. Topic: DLA15C001The introduction of substandard or counterfeit materials into the DoD supply chain can have extremely expensive, and potentially life threatening, consequences. Current techniques used to detect nonconforming materiel can be destructive (e.g., manual sectioning and inspection of a part), time consuming and expensive (e.g., micro-computed tomography, ultrasound), or provide only limited informatio ...
STTR Phase I 2016 Department of DefenseDefense Logistics Agency