  1. CRANE: Cervical Readiness Using Analytics and Non-Invasive Evaluation

    SBC: APTIMA INC            Topic: DHA18B001

    Current cervical spine assessment methodologies are focused on subjective measures (i.e. pain reports) and range-of-motion (ROM) measures that only measure maximum head excursion and reach, but not dynamic motion. Due to report bias and existing incentive

    STTR Phase I 2019 Department of DefenseDefense Health Agency
  2. No Power Bionic Lower Extremity Prostheses

    SBC: LIBERATING TECHNOLOGIES INC            Topic: DHP16C007

    Current prosthetic feet produce much less peak mechanical power than the able-bodied foot/ankle and release only about half of the mechanical energy generated during gait. This leads to higher energy expenditure among amputees as compared to able-bodied i

    STTR Phase II 2019 Department of DefenseDefense Health Agency
  3. Bio-mathematical Models of Aggregated Tissues & Organ Properties

    SBC: Corvid Innovation LLC            Topic: DHP16A001

    Realistic surgical simulation requires a combination of representative tissue geometry, accurate tissue material properties and lifelike tool-tissue interaction forces. Recent advances in computational power and imaging modalities have provided the capability to represent the anatomical details required for surgical training; however, the mathematical models which govern the underlying tissue pro ...

    STTR Phase I 2016 Department of DefenseDefense Health Agency
  4. Bio-Mathematical Models of Aggregated Tissues & Organ Properties

    SBC: BIOMOJO LLC            Topic: DHP16A001

    BioMojo LLC and the Departments of Mathematics and Biomedical Engineering at the University of North Carolina Chapel Hill, will develop a preliminary bio mathematical model framework to represent how human tissues interact and behave at their boundaries. Tissue interaction properties (e.g. tensile, shear, friction, and so forth) of connective, epithelial, muscular, and nervous tissue including su ...

    STTR Phase I 2016 Department of DefenseDefense Health Agency
  5. Innovative Mitigation of Radiation Effects in Advanced Technology Nodes

    SBC: RELIABLE MICROSYSTEMS LLC            Topic: DTRA16A003

    Establish a radiation-aware analysis capability in a commercial EDA design flow that will enable first-pass success in radiation-hardened by design (RHBD) for DoD ASICs in much the same way that existing EDA design suites ensure first pass functionality and performance success of complex ASICs destined for commercial applications. Layout-aware, calibrated single-event radiation models that captur ...

    STTR Phase I 2016 Department of DefenseDefense Threat Reduction Agency
  6. An Open-Source Platform for Inter-Network Analytics of High-Consequence Events

    SBC: ANOMALEE INC.            Topic: DTRA14B003

    Objectives and Intellectual Merit: The infrastructure of modern civilization is a set of complex systems1 that dynamically interact across multiple layers of abstraction. Researchers from many disciplines2 are designing analytical tools for predicting the global and local behaviors of these complicated, multi-layer networks. Easily usable, available (open source) and inter-operated tools are neede ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency
  7. Microscale Detector Materials for Covert, Ubiquitous Radiation Detector

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: DTRA14B004

    The proliferation of nuclear and radiological weapons of mass destruction is a serious threat in the world today. The goal of this proposal is to develop a new, very low cost radiation detection technology that will be useful for detection and for surveillance of individuals who have been near radioactive materials. The technology can also be used for dosimetry, and will provide the technology for ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency
  8. Large area, high efficiency, extremely light-weight portable neutron Detector

    SBC: TRITON SYSTEMS, INC.            Topic: DTRA14B005

    A drop-in 3He-tube replacement technology for thermal neutron detection does not exist today. It is critical for homeland security and nuclear safeguards applications. In this program, Triton Systems proposes to develop a light-weight, large-area, high efficiency portable neutron detector for passive interrogation using an innovative gas detector structure. The resulting 3He-free thermal neutron d ...

    STTR Phase I 2015 Department of DefenseDefense Threat Reduction Agency