Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY19 is not expected to be complete until June, 2020.

  1. 3D Tip Characterization and Surface Reconstruction

    SBC: Nanometrology International, Inc.            Topic: 9070168TT

    Nanometrology International, Inc. (NMI) proposes to demonstrate the feasibility of 3-dimensional (3D) characterization of nanoscale objects using scanning probe microscopy (SPM) with a measurement uncertainty of less than 0.7 nm. To accomplish this task, we propose a novel method of 3D tip characterization and use of an innovative surface reconstruction algorithm recently introduced by NIST and th ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  2. A High-Throughput Blood Esterase Panel Assay

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD10108

    Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  3. Analysis of New WWVB Modulation Schemes for Future Broadcast

    SBC: XW, LLC dba Xtendwave            Topic: N/A

    This Phase 2 project targets the completion of the development of an improved system for the broadcasting of the WWVB signal, as a direct continuation of the Phase 1 project, which successfully validated the proposed approach through a feasibility study and analyses. Objectives of this project include the design of the new modulation scheme and protocol, the development of a new time-code generato ...

    SBIR Phase II 2011 Department of CommerceNational Institute of Standards and Technology
  4. Biological Threat Identification Employing Force Amplified Biosensor Technology

    SBC: Systems & Processes Engineering Corporation            Topic: N/A

    Systems & Processes Engineering Corporation (SPEC) proposes to develop a highly sensitive point pathogen detection system based on Force Amplified Biosensor (FAB) technology. Similar to Atomic Force Microscopy (AFM). FAB employs a greatly simplified AFM configuration to measure intermolecular interactions. By employing immobilized antibodies and very small, well characterized, magnetic beads, ex ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  5. CBW Ensemble Protective Clothing

    SBC: Texas Research Institute, Austin, Inc.            Topic: N/A

    Protective clothing technology is a key element in chemical and biological defense, There is a need for a spray-on coating, similar to 3M's Scotch Gard1 which will enhance the barrier properties of standard protective clothing and aid in decontamination. Two approaches have been developed for fabric protection: (1) high surface free energy, low molecular weight resins which are chemically bonded t ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  6. CBW Safe Water Pouch

    SBC: Texas Research Institute, Austin, Inc.            Topic: N/A

    Recent events in the Middle East have focused worldwide attention toward the escalating threat of chemical and biological warfare. Naval Aviators exposed to potential CBW threats need a means to rehydrate themselves in the cockpit. Numerous studies have shown that proper hydration is essential for maximum physical and mental performance. Texas Research Institute Austin, Inc. (TRI/Austin) will te ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  7. Labeless, Reagentless, Biosensor

    SBC: AGAVE BIOSYSTEMS INC.            Topic: N/A

    The preponderance of biosensors under development today rely on labeling reagents such as fluorescent, radioisotopic or enzymatic tags. As a result, the added complexity of these reagents and their incorporation into the detection system has resulted in designs that are difficult to implement or that require significant sample preparation steps before introduction into the detection instrument. ...

    SBIR Phase I 1998 Department of DefenseOffice for Chemical and Biological Defense
  8. Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD11109

    Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  9. Narrowband Perfect Absorber using Metamaterials

    SBC: Phoebus Optoelectronics LLC            Topic: CBD11102

    We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  10. No Power Detection and Identification of Nerve Agents

    SBC: Lynntech Inc.            Topic: CBD10101

    Identification of organophosphates (OPs) based nerve agents, is vital to the protection of U.S. armed forces personnel. Existing detection methods use bulky and expensive laboratory equipment, negating their battlefield use. Colorimetric indicators such as the currently deployed M8 and M9 detection papers are the fastest, cheapest, and easiest type of detector to use; however, these cannot detect ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government