Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY19 is not expected to be complete until June, 2020.

  1. 3D Tip Characterization and Surface Reconstruction

    SBC: Nanometrology International, Inc.            Topic: 9070168TT

    Nanometrology International, Inc. (NMI) proposes to demonstrate the feasibility of 3-dimensional (3D) characterization of nanoscale objects using scanning probe microscopy (SPM) with a measurement uncertainty of less than 0.7 nm. To accomplish this task, we propose a novel method of 3D tip characterization and use of an innovative surface reconstruction algorithm recently introduced by NIST and th ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  2. A High-Throughput Blood Esterase Panel Assay

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD10108

    Organophosphorus chemical warfare nerve agents (OP-CWA) are attractive to terrorist groups and rogue states as an inexpensive and accessible technology for chemical warfare. OP-CWA and organophosphate pesticides cause severe neurological symptoms and death by inhibiting the enzyme acetylcholinesterase (AChE); the resulting excess acetylcholine accumulates and overstimulates the human or animal bo ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  3. Analysis of New WWVB Modulation Schemes for Future Broadcast

    SBC: XW, LLC dba Xtendwave            Topic: N/A

    This Phase 2 project targets the completion of the development of an improved system for the broadcasting of the WWVB signal, as a direct continuation of the Phase 1 project, which successfully validated the proposed approach through a feasibility study and analyses. Objectives of this project include the design of the new modulation scheme and protocol, the development of a new time-code generato ...

    SBIR Phase II 2011 Department of CommerceNational Institute of Standards and Technology
  4. Fiber Pigtailed On-Chip Mid-infrared Difference Frequency Generation in Silicon

    SBC: Omega Optics, Inc.            Topic: NA

    We propose a fiber-pigtailed strained silicon platform for tunable difference frequency generation (DFG) in mid-infrared (MIR) with tunable continuous wave near-infrared (NIR) sources. Stress exerted by silicon nitride induces second-order nonlinear susceptibility c(2) on underlying centro-symmetric silicon. NIR light is coupled into silicon and MIR light is coupled out of silicon using sub-wavele ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  5. High Temperature High Resolution in-situ Differential Pressure Sensor

    SBC: Innoveering, LLC            Topic: NA

    Chemical manufacturers require high accuracy/high sensitivity pressure sensors to efficiently monitor the various manufacturing systems and processes in the chemical plant, to ensure any changes proceed in a safe and reliable manner, adhering to expected standards and practices. NIST also has a need for highly accurate pressure measurements, especially determining the thermo-physical properties of ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  6. Multiplex Microsphere Assay for Botulinum Neutralizing Antibodies

    SBC: AGAVE BIOSYSTEMS INC.            Topic: CBD11109

    Currently, the accepted standard experimental model for measuring protective efficacy against botulism is the Mouse Lethality Neutralization (MLN) assay. Botulism poisoning is a life threatening condition that is not only a public health concern, but could also be a potential biological weapon. With seven serotypes of botulinum neurotoxins, there is need for an alternative to the MLN assay due t ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  7. Narrowband Perfect Absorber using Metamaterials

    SBC: Phoebus Optoelectronics LLC            Topic: CBD11102

    We propose a metamaterial-enhanced microbolometer with strong absorption over a narrow band that is dynamically tunable over the 8-10 micron band. A single-layer photonic metamaterial consisting of a thin metal film perforated with a 2-D array of dielectric apertures will be deposited on an amorphous-Silicon layer acting as an absorber and bolometer. The metamaterial, in conjunction with planar di ...

    SBIR Phase I 2011 Department of DefenseOffice for Chemical and Biological Defense
  8. No Power Detection and Identification of Nerve Agents

    SBC: Lynntech Inc.            Topic: CBD10101

    Identification of organophosphates (OPs) based nerve agents, is vital to the protection of U.S. armed forces personnel. Existing detection methods use bulky and expensive laboratory equipment, negating their battlefield use. Colorimetric indicators such as the currently deployed M8 and M9 detection papers are the fastest, cheapest, and easiest type of detector to use; however, these cannot detect ...

    SBIR Phase II 2011 Department of DefenseOffice for Chemical and Biological Defense
  9. Optical Device for Sorting Particles by Size

    SBC: En'urga Inc.            Topic: NA

    This Small Business Innovation Research Phase 1 project will evaluate the feasibility of an innovative optical sizer for estimating drop sizes in sprays that have very small drops. The technique is based on the NIST provisional patent (application number 62/358,264). The NIST invention sorts particles by size over the range of 10nm to 10μm. Drop sizing is achieved in these sprays using an intense ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  10. Precision 10 kV Programmable Voltage Source

    SBC: Low Thermal Electronics, Inc.            Topic: NA

    Low Thermal Electronics, Inc. proposes to design a stand-alone, programmable voltage source capable of supplying precision voltages in the range of zero to 1,000 volts direct current (DC), with options for scaling up to 10,000 volts, and with a total expanded uncertainty (k=2) of less than 10uV/V for the 10,000 volt version. This instrument will improve state-of-the-art measurements in high resist ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government