  1. 3D Tip Characterization and Surface Reconstruction

    SBC: Nanometrology International, Inc.            Topic: 9070168TT

    Nanometrology International, Inc. (NMI) proposes to demonstrate the feasibility of 3-dimensional (3D) characterization of nanoscale objects using scanning probe microscopy (SPM) with a measurement uncertainty of less than 0.7 nm. To accomplish this task, we propose a novel method of 3D tip characterization and use of an innovative surface reconstruction algorithm recently introduced by NIST and th ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
  2. Technology Transfer of Multimodal Biometric Application Resource Kit (MBARK)

    SBC: Ad Harmony            Topic: N/A

    The technical objective of this project is to develop a prototype of a face recognition application in a cloud computing environment utilizing MBARK as the middleware. The application will have a client piece that will run on a mobile device such as a laptop and a server piece that will run on a higher-performance computing cluster. The specific objectives of this development project can be enumer ...

    SBIR Phase II 2011 Department of CommerceNational Institute of Standards and Technology
  3. Analysis of New WWVB Modulation Schemes for Future Broadcast

    SBC: XW, LLC dba Xtendwave            Topic: N/A

    This Phase 2 project targets the completion of the development of an improved system for the broadcasting of the WWVB signal, as a direct continuation of the Phase 1 project, which successfully validated the proposed approach through a feasibility study and analyses. Objectives of this project include the design of the new modulation scheme and protocol, the development of a new time-code generato ...

    SBIR Phase II 2011 Department of CommerceNational Institute of Standards and Technology
  4. Precision 10 kV Programmable Voltage Source

    SBC: Low Thermal Electronics, Inc.            Topic: NA

    Low Thermal Electronics, Inc. proposes to design a stand-alone, programmable voltage source capable of supplying precision voltages in the range of zero to 1,000 volts direct current (DC), with options for scaling up to 10,000 volts, and with a total expanded uncertainty (k=2) of less than 10uV/V for the 10,000 volt version. This instrument will improve state-of-the-art measurements in high resist ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  5. Optical Device for Sorting Particles by Size

    SBC: En'urga Inc.            Topic: NA

    This Small Business Innovation Research Phase 1 project will evaluate the feasibility of an innovative optical sizer for estimating drop sizes in sprays that have very small drops. The technique is based on the NIST provisional patent (application number 62/358,264). The NIST invention sorts particles by size over the range of 10nm to 10μm. Drop sizing is achieved in these sprays using an intense ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  6. Fiber Pigtailed On-Chip Mid-infrared Difference Frequency Generation in Silicon

    SBC: OMEGA OPTICS, INC.            Topic: NA

    We propose a fiber-pigtailed strained silicon platform for tunable difference frequency generation (DFG) in mid-infrared (MIR) with tunable continuous wave near-infrared (NIR) sources. Stress exerted by silicon nitride induces second-order nonlinear susceptibility c(2) on underlying centro-symmetric silicon. NIR light is coupled into silicon and MIR light is coupled out of silicon using sub-wavele ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  7. High Temperature High Resolution in-situ Differential Pressure Sensor

    SBC: Innoveering, LLC            Topic: NA

    Chemical manufacturers require high accuracy/high sensitivity pressure sensors to efficiently monitor the various manufacturing systems and processes in the chemical plant, to ensure any changes proceed in a safe and reliable manner, adhering to expected standards and practices. NIST also has a need for highly accurate pressure measurements, especially determining the thermo-physical properties of ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology