You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Interactive Software Tools for Processing QIF-formatted Part Models to Generate Realistic and Accurate Measurement Plans and Programs in Standard Digital Languages

    SBC: CAPVIDIA NA LLC            Topic: NA

    The QIF standard shows the promise of offering an environment where best-in-class metrology applications can be linked to yield solutions that are automated, optimized, adaptive, and traceable, maintaining the agility required to ensure U. S. global competitiveness. While the QIF standard has reached a substantial level of comprehensiveness and maturity, the embodiment of the standard in actual, c ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  2. Large Field of View Microscope for Rapid, High-Resolution Imaging

    SBC: NIKIRA LABS INC.            Topic: NA

    In this SBIR effort, Nikira Labs Inc. proposes to develop a high-resolution (< 1 micron) microscope that can rapidly (< 30 seconds) image a large field of view (> 1 cm2). The technology will provide both bright-field and fluorescence imaging and be capable of retrofitting into a wide variety of existing microscopes at a low retail price. This work will complement the microscopy efforts that are on ...

    SBIR Phase I 2017 Department of CommerceNational Institute of Standards and Technology
  3. Horizon: Validation of an improved method for rapid characterization of protein aggregates in biologic drugs for increased quality and safety

    SBC: OPTOFLUIDICS, INC.            Topic: NA

    Optofluidics and the University of Delaware propose to complete the development of the Horizon technology and carry out validation via a comprehensive multi-site study. The technology is a subvisible particle analyzer pioneered during Phase I. The technology is designed to fill two critical gaps in biopharmaceutical product development: (1) Scientists can count and image particles with current too ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  4. Air Movement Efficiency Monitor

    SBC: XCSPEC, Inc.            Topic: NA

    The Air Movement Efficiency Monitor is composed of small, inexpensive Microelectromechanical system (MEMS) sensors, connected wirelessly to the Internet, and distributed through a building to measure pressure readings at key points. We consider this a “FitBit” for a building’s air-movement efficiency, employing many of the sensors used by a fitbit – temperature, humidity, acceleration. We ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  5. Visual Part Identification, Localization, and Manipulation with Deep Networks

    SBC: SYMBIO ROBOTICS, INC.            Topic: NA

    During Phase I, Symbio Robotics conducted initial development of a robust, real-time, high-performance, low-cost perception engine made possible by recent advances in deep learning. This system identifies parts in 2D or 3D images and determines their six degree-of-freedom poses, producing a full description of a scene in a fraction of a second. For this technology to be practically useful in manuf ...

    SBIR Phase II 2017 Department of CommerceNational Institute of Standards and Technology
  6. Low-Noise Detector Arrays for Raman Spectroscopy

    SBC: Aerius Photonics, LLC.            Topic: N/A

    We propose to demonstrate near infrared (NIR) InGaAs sensor arrays with 55% lower noise than arrays presently available to improve the sensitivity of current spectroscopy systems. The low noise performance will be enabled by the use of low-noise source follower per detector ROICs, which are also used in astronomy with HgCdTe for low noise measurements. With design improvements to current available ...

    SBIR Phase I 2006 Department of CommerceNational Institute of Standards and Technology
  7. Development of a High Sensitivity Laser-induced Incandescence Instrument for Characterizing Soot and Carbonaceous Particles

    SBC: ARTIUM TECHNOLOGIES, INC.            Topic: N/A

    A high sensitivity laser-induced incandescence system is proposed for the detailed characterization of environmental soot. The Phase 1 effort has clearly demonstrated the feasibility of (1) reducing the lower detection limit of soot volume fraction and increasing the overall measurement range by at least 2 orders of magnitude from what is currently achievable, and (2) providing PM particle size me ...

    SBIR Phase II 2006 Department of CommerceNational Institute of Standards and Technology
  8. Holographic Light-Emitting Diode-Based Solar Simulator

    SBC: Physical Optics Corporation            Topic: N/A

    NIST is seeking a large area solar simulator to overcome the shortcomings of current solar simulators. To meet this need, Physical Optics Corp. (POC) proposed to develop a new Holographic Light-Emitting-Diode-Based Solar Simulator (HOLIOS) based on holographic gratings, holographic diffuser, high-power light emitting diodes with electronic drivers, collimating and projection optics, and photodetec ...

    SBIR Phase I 2006 Department of CommerceNational Institute of Standards and Technology
  9. Imaging Variable Kinetic Energy Electron Analyzer

    SBC: R. Browning Consultants            Topic: N/A

    The objective of this proposal is to create a prototype imaging variable kinetic energy electron analyzer in the range 0.1 to 8 keV for use with an X-ray excitation source. The imaging analyzer is to have a target imaging spatial resolution of 100 nm. The X-ray excitation source will be a synchrotron light source. The instrument can be described as an X-ray photoelectron spectroscopy (XPS) microsc ...

    SBIR Phase I 2006 Department of CommerceNational Institute of Standards and Technology