  1. Proof of Concept Demonstration of a Compact Accelerator

    SBC: Passport Systems, Inc.            Topic: HSB072007

    Electron accelerators that produce high duty cycle electron beams with beam energies up to 9 MeV are essential for use in practical Nuclear Resonance Fluorescence and EZ-3DTM imaging technologies. While isotopic identification of shielded materials is now possible via these technologies, it is still necessary to achieve accelerator portability, compactness and reasonable cost of ownership to make ...

    SBIR Phase II 2008 Department of Homeland Security
  2. Handheld Trace Explosives Sampler

    SBC: Implant Sciences Corporation            Topic: HSB071001

    Non contact trace explosives detection has not been comparable to results obtained from wipe sampling. Many issues, including finding a method to release particles from a surface, efficient particle and vapor transport, and limited particle and vapor trap collection efficiency have all limited the process. Other related issues have included cost of ownership, ease of contamination removal, and com ...

    SBIR Phase II 2008 Department of Homeland Security
  3. Radiological Source Surveillance With V-RADS Video-Centric Radiatiion Detection

    SBC: ADVANCED FUEL RESEARCH, INC.            Topic: N/A

    Radiological sources are in everyday use in numerous industries. Illicit removal of this material from storage could result in construction of a Radiological Dispersal Device or "Dirty Bomb." A pervasive means of securing radiological materials and identifying breaches in security is required. Ideally, existing passive surveillance technology would be used, thereby enabling rapid and cost effectiv ...

    SBIR Phase II 2008 Department of Homeland Security
  4. "Typical day" Meteorological Data for Atmospheric Transport and Dispersion (ATD) Modeling

    SBC: ATMOSPHERIC & ENVIRONMENTAL RESEARCH, INC.            Topic: DTRA06004

    The complexity of Atmospheric Transport and Dispersion (ATD) modeling requires physically consistent weather data evolving in both space and time. Spatially and/or temporally averaged data found in climatological products is not suitable for ATD modeling. The proposed solution for providing “typical day” meteorological data couples innovative search techniques applied to long-range historical ...

    SBIR Phase I 2006 Department of DefenseDefense Threat Reduction Agency
  5. Extending DTRA's Atmospheric Transport and Diffusion Modeling Capabilities to the Upper Atmosphere

    SBC: ATMOSPHERIC & ENVIRONMENTAL RESEARCH, INC.            Topic: DTRA06005

    Atmospheric and Environmental Research, Inc. proposes to develop a prototype threat-reduction system for the dispersion of a weapons-of-mass destruction warhead in the upper atmosphere. Our system will extend current DTRA atmospheric transport and dispersion capabilities into the 20-120 km altitude region. This will be accomplished using a combination of a zonally-averaged transport model of the s ...

    SBIR Phase I 2006 Department of DefenseDefense Threat Reduction Agency
  6. RELIABLE PEROXIDE-BASED EXPLOSIVES DETECTION WITH LOW FALSE ALARM RATE

    SBC: AGILTRON, INC.            Topic: HSB061002

    We propose a new trace explosive collection and detection technique comprising Surface-Enhanced Raman Scattering (SERS) sampling chip and cell design of permeable/porous polymer matrix embedded with multi-layered gold nano-particles. The approach leverages the leading-edge micro-optical component development and manufacture at Agiltron and extensive experience in nano-material engineering within t ...

    SBIR Phase I 2006 Department of Homeland Security
  7. High Quantum Efficiency Fast Detectors for the Readout of Scintillators for Gamma Ray Detection

    SBC: AGILTRON, INC.            Topic: HSB062007

    Agiltron proposes to demonstrate a breakthrough detector for readout of scintillators for gamma ray detection that overcomes the quantum efficiency and high voltage limits of current PMTs and APDs. It holds the promise to improve the current scintillator detector resolution by at least 30 percent without the need for a high voltage power supply, and can be fabricated at a low cost. This new photom ...

    SBIR Phase I 2006 Department of Homeland Security
  8. Advanced nanocomposite scintillator for gamma radiation detection

    SBC: AGILTRON, INC.            Topic: DTRA08005

    Until now gamma radiation detection has required large single crystals of sensitive materials that are difficult to produce consistently on an industrial scale. In collaboration with a research group at the University of Texas at Arlington, Agiltron proposes to develop a new class of nanocomposite scintillator materials. The radiation detection characteristics of the synthetic nanoparticles in the ...

    SBIR Phase I 2008 Department of DefenseDefense Threat Reduction Agency
  9. High Resolution, Room Temperature Semiconductor Detectors

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: DTRA05006

    Proliferation of the weapons of mass destruction such as nuclear weapons is a serious threat in the world today. Prevention of the spread of nuclear weapons has reached a state of heightened urgency in recent years, especially since the events on September 11, 2001 and its aftermath. Gamma ray spectrometers are an important tool in checking the proliferation of the nuclear weapons. Important re ...

    SBIR Phase II 2006 Department of DefenseDefense Threat Reduction Agency
  10. High Quantum Efficiency, Fast Detectors for the Readout of Scintillators for Gamma-Ray Detection

    SBC: RADIATION MONITORING DEVICES, INC.            Topic: N/A

    Gamma-ray spectrometers consisting of inorganic scintillators coupled to optical detectors such as photomultiplier tubes (PMTs) are an important element of the systems that are used to monitor and prevent the spread of special nuclear materials. Two very important requirements for the scintillation detectors used as gamma-ray spectrometers in homeland security monitoring include high sensitivity a ...