You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Fabrication of Advanced Waveguide Structures for Efficient Violet and Near-UV Generation

    SBC: ADVR, INC.            Topic: N/A

    This SBIR Phase I effort will establish the feasibility of fabricating advanced waveguide structures in potassium titanyl phosphate (KTP) capable of efficiently generating 25 to 40 mW of frequency converted light in the 395 to 480 nm. The key innovation in this effort is to utilize KTP waveguides in a single-pass frequency doubling device to efficiently produce the desired laser wavelengths and po ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  2. High Efficiency Up conversion Single-Photon-Detector for 1550 nm Signal

    SBC: ADVR, INC.            Topic: N/A

    This NIST Phase II SBIR effort will two low noise single photon detectors using MgO doped LiNbO3 (LN) periodically poled waveguides and a 980nm (or similar appropriate wavelength) pump to up convert 1550nm photons to 600nm to allow for detection by photomultiplier tube (PMT). The key innovation is using low noise periodically poled waveguides with a long wavelength (1800nm) pump leading to higher ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  3. Nanoparticle Characterization in Fluid by Resonant Mass Measurement

    SBC: Affinity Biosensors, LLC            Topic: N/A

    This project will extend the microchannel resonator to the level of a few attograms, which will allow measurement of individual particles as small as 10 nanometers with unprecedented resolution. The Phase I effort will prove the feasibility of this approach by miniaturizing the MEMS sensors, thereby improving their intrinsic mass sensitivity up to 100-fold; and by simultaneously measuring the sens ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  4. Cultural Intelligence Wiki-Berry

    SBC: Anacapa Sciences, Inc.            Topic: SOCOM07006

    This proposal offers a detailed work plan to conduct the research and development tasks necessary to produce a system composed of software, application servers, PCs, and handheld computers for use by highly-mobile military personnel to collect and process cultural information, intelligence, and data. Development of the system will be facilitated by our extensive military research and operational e ...

    SBIR Phase II 2009 Department of DefenseSpecial Operations Command
  5. Frequency Stable Optically Pumped Semiconductor Lasers

    SBC: Arete Associates            Topic: N/A

    Technology research and development in such areas as next-generation atomic clocks, quantum information processing with trapped ions, and atomic spectroscopy is impeded by the lack of commercially available laser sources that meet the required specifications of wavelength tuning range, output power, frequency-stability and reliability. Arete Associates is developing frequency-stable Optically Pump ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  6. Development of Pulse/DC Characterization System for LEDs

    SBC: Arroyo Instruments, LLC            Topic: N/A

    The purpose of this project is to implement the process for a new method for the measurement of LED performance, but in a form that is low-cost, integrated, and easy-to-use, so that the barrier to entry is as low as is possible.

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  7. AC Amplifier and System for Nanopore Based DNA Sequencing

    SBC: ELECTRONIC BIOSCIENCES, INC.            Topic: N/A

    The characterization of biologically relevant polymetric materials is a major focus of the bioinstrumentation industry. Of particular interest is the rapid, direct sequencing of DNA through a nanopore as well as the characterization of other biopolymers. Although progress has been made with nanopore sequencing, some fundamental instrumental and system issues have so far kept the method from realiz ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  8. Flare with Optically Invisible Light Signature (Foils)

    SBC: EXQUADRUM INC            Topic: SOCOM09002

    The proposed program will theoretically and experimentally assess and identify innovative technologies, and advanced materials that emit an effective infra-red (IR) countermeasure in the desired IR spectrum range while minimizing detectable signatures in the visible light spectrum. During the research effort, the project team will develop the initial technical design and supporting documentation f ...

    SBIR Phase I 2009 Department of DefenseSpecial Operations Command
  9. A Method for Specification of Efficient and Effective Strategies for Measurement of a Measurement Article on a Coordinate Measuring Machine by Use of Measurement Simulation Techniques

    SBC: METROSAGE, L L C            Topic: N/A

    We propose the definition, design, and prototype development of a software tool for use by the U.S. manufacturing community to enable the automated production of design-based measurement strategies of known reliability and high economic efficiency for coordinate measuring machines (CMMs). The measurement strategies so generated will meet the objective of reducing overall costs to near-minimal valu ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  10. Three Axis Interferometer for Distance and Tip-Tilt Measurement

    SBC: Optical Physics Company            Topic: N/A

    During the Phase I SBIR project Optical Physics Company (OPC) investigated a three axis interferometer instrument which measures the one dimensional linear translation and the two-dimensional angular deflection in pitch and yaw of a 7 mm mirror 18-23 cm away. Lab demonstrations both before and during the Phase I effort showed performance parameters better than NIST requirements. The Phase I effort ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government