You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Biologic Event Identification and Geolocation Unattended Ground Sensor

    SBC: STREAMLINE AUTOMATION LLC            Topic: SOCOM06018

    The DoD Chemical, Biological, Radiological, and Nuclear Defense Program Performance Plan discusses the status of sensing technologies and long-term goals, and shows point biological detection systems are expected to provide 20% of the objective capabilities in FY15. This indicates that there is the need for a man-portable, disposable, rapidly responding biological agent point detector that is capa ...

    SBIR Phase II 2008 Department of DefenseSpecial Operations Command
  2. A Novel, Low Power, High Throughput, High Efficiency, Scalable Electrostatic Bioaerosol Sampler

    SBC: CFD RESEARCH CORPORATION            Topic: HSB041003

    Current bioaerosol monitoring strategies rely on inertia-based sampling and suffer from high power consumption and low efficiency limitations. In contrast, our overall objective is to design and demonstrate a novel electrostatic sampler that provides dramatic improvements including low power requirement (90% for 1-10mm), high viability (>80%), scalability for varying threat scenarios, low noise, a ...

    SBIR Phase I 2004 Department of Homeland Security
  3. Deep Submergence Rated Flexible Hoses and Piping System Connectors

    SBC: MEI-CHARLTON, INC.            Topic: SOCOM08002

    The objective of this proposal is to demonstrate the feasibility of developing flex hoses for hydraulic and other piping system interfaces that can withstand high pressure environments, hydrodynamic, and other forces unique to deep submergence system operating environments. This hose and connecter system coined FlexiHOSE© proposed by MEI-Charlton, Inc. (MEIC) will meet the need of operating under ...

    SBIR Phase I 2008 Department of DefenseSpecial Operations Command
  4. Miniature Quickscan Receiver

    SBC: OCEANIT LABORATORIES INC            Topic: SOCOM04004

    Special Operation Forces personnel require a rugged, miniature receiver that is capable of monitoring RF energy while deployed on a mission. The RF receiver will give a better picture of the electromagnetic threat environment enabling a heightened situational awareness, yet the device must be small enough that it does not hamper the SOF warfighter during missions requiring stealth and rapid mobil ...

    SBIR Phase I 2004 Department of DefenseSpecial Operations Command
  5. WISPER (Wireless Intelligent Sensor Platform for Emergency Responders)

    SBC: OCEANIT LABORATORIES INC            Topic: HSB072004

    Oceanit proposes to develop a low cost, reliable, wireless mesh networking system that will enable remote monitoring and tracking of sensors on emergency responders in hostile building environments. The heart of the system will use a commercial-off-the-shelf (COTS) wireless mesh networking IC platform for low-power and low-cost communications. By using a wireless mesh network, low-power wireless t ...

    SBIR Phase II 2008 Department of Homeland Security
  6. CMOS FET and AlGaN MODFET Receptor Scaffold for Molecular Recognition and Direct Detection

    SBC: Peterson Ridge LLC            Topic: N/A

    This project is designed to test a novel receptor scaffold/sensor combination for the selective and direct measurement of antigens and to compare direct electric detection of antigens against the corresponding antibody based ELISA method. The scaffold concept combines a robust nucleic acid receptor (aptamer) coupled to a low cost CMOS FET and AlGaN MODFET transducer. Aptamers are short nucleic aci ...

    SBIR Phase I 2004 Department of Homeland Security
  7. Marine Asset Tag Using Near Field Electromagnetic Ranging

    SBC: Q-Track Corporation            Topic: N/A

    We propose a Marine Asset Tag Tracking System (MATTS) using a breakthrough wireless tracking technology called near field electromagnetic ranging (NFER¿). The primary objective of Phase I is to validate that NFER¿ technology is the best RF solution for tracking containers on ships and in ports. Phase I will also (1) develop an overall architecture for the MATTS; (2) design the container tag; ...

    SBIR Phase I 2004 Department of Homeland Security
  8. Crypto-Secure Remote Terminal Unit for New and Retrofit Supervisory Control and Data Acquisition

    SBC: RIGHT STUFF OF TAHOE INC            Topic: N/A

    We propose to develop an integrated Cryptography Module (CM) and RTU (CMRTU) for SCADA applications. When used in CM mode, our CMRTU will be easily retrofitted into existing SCADA networks. When used in advanced RTU mode (where higher bandwidth connections are available), our CMRTU will provide both a secure gateway function and secure Internet protocols for interaction with either central monitor ...

    SBIR Phase I 2004 Department of Homeland Security
  9. Efficient Low-Dark-Count Detector for Photon Counting

    SBC: VOXTEL, INC.            Topic: N/A

    Voxtel proposes to develop fiber-coupled near-infrared avalanche photodiode (APD) receivers with photon detection efficiency (PDE) and dark count rate (DCR) with more than two orders of magnitude faster maximum count rate (MCR) than Geiger-mode APDs, which are constrained by a fundamental tradeoff between DCR and MCR: if the APD is cooled to reduce DCR, then its dead time must increase to avoid af ...

    SBIR Phase I 2008 Department of CommerceNational Institute of Standards and Technology
  10. Phage Derived Receptor Scaffold

    SBC: WELD STAR TECHNOLOGY, INC.            Topic: N/A

    The risk of biological terrorism is significant because of the high potency, widespread availability, and ease of dissemination of some biological threat agents. The earliest recognition of a bioterrorist attack may be indicated only by the clinical manifestation of the intended disease which, in some cases, can take days to weeks to present itself. Furthermore, laboratory confirmation of the diag ...

    SBIR Phase I 2004 Department of Homeland Security
US Flag An Official Website of the United States Government