List

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY19 is not expected to be complete until April, 2020.

  1. MICRO COMPUTER BASED PARALLEL PROCESSING SYSTEM FOR CODE COMPUTATIONS

    SBC: Risk Management Systems            Topic: N/A

    THE RESEARCH PROGRAM WILL DEVELOP A MICROCOMPUTER BASED SYSTEM OF HARDWARE AND SOFTWARE WHICH WILL ALLOW THE USER TOEXECUTE MAINFRAME BASED CODES ON THE MICROCOMPUTER. IN ADDITION PARALLEL EXECUTION OF SEVERAL CODES AT ONCE IS POSSIBLEA SPECIAL INPUT AND OUTPUT PROCESSOR MODULES WILL ALSO BE DEVELOPED TO DEMONSTRATE THE USER FRIENDLY CAPABILITIES OF THE SYSTEM AND FACILITATE INPUT PREPARATION AND ...

    SBIR Phase II 1989 Nuclear Regulatory Commission
  2. A PORTABLE IMAGING SYSTEM FOR NONDESTRUCTIVE EXAMINATION OF NUCLEAR POWER PLANT COMPONENTS

    SBC: TPL, INC.            Topic: N/A

    THE DIFFICULTY IN PREDICTING STRUCTURAL DEGRADATION RATES FOR NUCLEAR POWER PLANT COMPONENTS DUE TO CORROSION AND OTHER FACTORS HAS LED TO THE NEED FOR COSTLY, TIME CONSUMING INSPECTIONS AND INCREASED COST FROM INTENTIONALLY OVERDESIGNED COMPONENTS. THE SITUATION INDICATES A SERIOUS, UNMET NEED FOR A SIMPLE BUT ACCURATE SYSTEM FOR REAL- TIME, IN SITU, NONDESTRUCTIVE ANALYSIS OF NUCLEAR POWER PLANT ...

    SBIR Phase II 1994 Nuclear Regulatory Commission
  3. High Efficiency, Large-Area, 1550 nm InGaAs Photodiodes

    SBC: VOXTEL, INC.            Topic: N/A

    A back-illuminated planar InGaAs photodiode tested to have 95% quantum effiiency (QE) at 1550 nm, area greater than 1 mm2, low capacitance (<23 pF), and high bandwidth (>125 MHz) will be improved. Although the existing Phase I device exhibited bulk material dark current generation better than commercially available devices, the sidewall-generated dark current was found to dominate the noise ...

    SBIR Phase II 2010 Department of CommerceNational Institute of Standards and Technology
  4. High Power, Mid-Infrared Fiber Supercontinuum Light Source

    SBC: MESA PHOTONICS, LLC            Topic: N/A

    Modern supercontinuum (SC) light sources are generated by non-linear interactions between ultrashort laser pulses and optical fibers. These light sources have high brightness and are spatially coherent. Output in near-ultraviolet to near-infrared wavelength ranges has been demonstrated. SC wavelength ranges are constrained by the transmission and dispersion properties of the fibers. Previously, ou ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  5. Innovative Residential Fire Detection

    SBC: Southwest Sciences, Inc.            Topic: N/A

    Southwest Sciences¿ Phase 2 SBIR project will lead to development of residential fire sensing systems based on recently developed, low cost temperature and optical imaging sensors combined with newly introduced highly miniaturized, micropower CO sensors. Sensor modules will be part of a low power wireless network. Each module will be about ½ the size of a business card, a few mm thick, and w ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  6. Low-Cost Microcalorimeter Spectrometer for X-Ray Macroanalysis

    SBC: STAR CRYOELECTRONICS LLC            Topic: N/A

    A low-cost superconducting transition edge sensor (TES) microcalorimeter spectrometer is described for high energy and high spatial resolution X-ray energy dispersive spectroscopy and microanalysis. The proposed microcalorimeter instrument offers an energy resolution that is comparable to and potentially even better than wavelength dispersive spectrometers, thereby enabling the resolution of inter ...

    SBIR Phase II 2005 Department of CommerceNational Institute of Standards and Technology
  7. Microcalorimeter Alpha Spectrometer for Analysis of Nuclear Material

    SBC: STAR CRYOELECTRONICS LLC            Topic: N/A

    A key factor of international efforts to identify and suppress the supply of and demand for nuclear materials, and thereby to deter potential traffickers, is the ability to accurately identify contradicted material and ultimately to trace it back to its origin. Alpha particle spectroscopy is widely used in nuclear forensics to assay trace quantities of sensitive nuclear materials, but the limited ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  8. Efficient Low-Dark-Count Detector for Photon Counting

    SBC: VOXTEL, INC.            Topic: N/A

    Voxtel has demonstrated efficient high-speed photon counting with thresholded linear-mode avalanche photodiode (APD) receivers using multi-gain-stage InGaAs/InAIAs APDs. In contrast to Geiger APDs, thresholded photon-counting linear APD receivers are thought not to suffer afterpulsing, and can support maximum count rates (MCR) up to 2 or 3 orders of magnitude faster than Geiger APDs. However, the ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  9. Anion Exchange Resin for Chirality-based Separation of Single-wall Carbon Nanotubes

    SBC: Sepax Technologies, Inc.            Topic: N/A

    Sepax Technologies, Inc. has identified a new type of anoin-exchange resin which separates single-wall carbon nanotubes (SWCNTs) with >80% recovery yield and resolves in a single pass the chiral tubes of (6,5) well from commercial SWCNT starting materials by Chromatography. Improvement and scale up of the targeted resin production will facilitate the separation of chiral nanotubes for the academic ...

    SBIR Phase II 2012 Department of CommerceNational Institute of Standards and Technology
  10. Improved Microcalorimeter Detectors for X-ray Chemical Shift Mapping

    SBC: STAR CRYOELECTRONICS LLC            Topic: 9020868TT

    X-ray fluorescence spectroscopy is a widely used and extremely sensitive analytical technique for qualitative and quantitative chemical analysis. Superconducting Transition Edge Sensor (TES) microcalorimeter detectors have now been developed that achieve an energy resolution of 2 eV for 1.5 keV X-rays, which is sufficient to enable the measurement of the small shift of the X-ray line position that ...

    SBIR Phase II 2013 Department of CommerceNational Institute of Standards and Technology

Agency Micro-sites

SBA logo
Department of Agriculture logo
Department of Commerce logo
Department of Defense logo
Department of Education logo
Department of Energy logo
Department of Health and Human Services logo
Department of Homeland Security logo
Department of Transportation logo
Environmental Protection Agency logo
National Aeronautics and Space Administration logo
National Science Foundation logo
US Flag An Official Website of the United States Government