You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. An Automated Lapping Apparatus and Process for High-Precision Random Profile Roughness Specimen Fabrication

    SBC: X-Wave Innovations, Inc.            Topic: 9020268TT

    The measurement and quality control for smooth engineering surfaces are becoming more and more important in modern science and technology due to their important engineering functions and high production costs. NIST has frequently received requests from U.S. industry to provide Standard Reference Material (SRM) high-precision, random profile roughness specimens to support smooth surface measurement ...

    SBIR Phase II 2013 Department of CommerceNational Institute of Standards and Technology
  2. Improved Microcalorimeter Detectors for X-ray Chemical Shift Mapping

    SBC: STAR CRYOELECTRONICS, LLC            Topic: 9020868TT

    X-ray fluorescence spectroscopy is a widely used and extremely sensitive analytical technique for qualitative and quantitative chemical analysis. Superconducting Transition Edge Sensor (TES) microcalorimeter detectors have now been developed that achieve an energy resolution of 2 eV for 1.5 keV X-rays, which is sufficient to enable the measurement of the small shift of the X-ray line position that ...

    SBIR Phase II 2013 Department of CommerceNational Institute of Standards and Technology
  3. High-Sensitivity, Low-Cost, Surface-Acoustic-Wave Based Microscale Thermogravimetric Analyzer for Nanoparticle Characterization

    SBC: X-Wave Innovations, Inc.            Topic: N/A

    To meet NIST’s need for development of a new electronic system for microscale thermogravimeter nanoparticle analysis, X-wave Innovations, Inc. (XII) proposes a high-sensitivity, high-accuracy, low-cost, surface-acoustic-wave based microscale thermogravimetric analyzer (SAW-µ-TGA). The proposed approach is based on XII-developed surface acoustic wave (SAW) sensor technology, which is capable of ...

    SBIR Phase I 2013 Department of CommerceNational Institute of Standards and Technology
  4. Climate Impact Visualization Tools Using Virtual 3D City for Community Based Planning and Outreach

    SBC: Intelligent Automation, Inc.            Topic: 931RC

    Intelligent Automation, Inc. proposes an innovative visualization tool that transforms online GIS mappers into a climate impact assessment and planning tool that allows planners to visualize the impact of storm surges with sea level rise and coastal erosion using a 3D virtual city. The goal is to assist planners and emergency services to adapt to climate change at three tiers: i) Tier 3 (Long-te ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  5. Dynamic Frequency Passive Millimeter-Wave Radiometer Based on Optical Up-Conversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: 941D

    In the proposed effort, we will leverage this extensive experience and capabilities to realize a frequency agile mmW radiometer that can cover the range of DC-110 GHz and can be scaled to DC-200 GHz under Phase II. Ours is a photonic system that multiplies and up-coverts a low-frequency reference signal onto an optical carrier (laser) using EO modulation, then uses the modulation sidebands to inj ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  6. SCAP Content Editor

    SBC: G2, INC.            Topic: N/A

    NIST and G2 have been on the forefront of security automation with the development of the Security Content Automation Protocol (SCAP). However, the barrier to entry for SCAP content creation is the requirement to have in depth knowledge of the underlying specifications. This project aims to allow security experts to create SCAP content without the need to be an expert in the specification. By leve ...

    SBIR Phase II 2012 Department of CommerceNational Institute of Standards and Technology
  7. Anion Exchange Resin for Chirality-based Separation of Single-wall Carbon Nanotubes

    SBC: Sepax Technologies, Inc.            Topic: N/A

    Sepax Technologies, Inc. has identified a new type of anoin-exchange resin which separates single-wall carbon nanotubes (SWCNTs) with >80% recovery yield and resolves in a single pass the chiral tubes of (6,5) well from commercial SWCNT starting materials by Chromatography. Improvement and scale up of the targeted resin production will facilitate the separation of chiral nanotubes for the academic ...

    SBIR Phase II 2012 Department of CommerceNational Institute of Standards and Technology
  8. Improved Microcalorimeter Detectors for X-Ray Chemical Shift Mapping

    SBC: STAR CRYOELECTRONICS, LLC            Topic: N/A

    X-ray fluorescence spectroscopy is a widely used and extremely sensitive analytical technique for qualitative as well as quantitative chemical analysis. Superconducting Transition Edge Sensor (TES) microcalorimeter detectors have now been developed that achieve an energy resolution of 2 eV (full width at half maximum) for 1.5 keV X-rays, which is sufficient to enable the measurement of the small s ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
  9. An Automated Lapping Apparatus and Process for High- Process for High-Precision Random Profile Roughness Specimen Fabrication

    SBC: X-Wave Innovations, Inc.            Topic: N/A

    The measurement and quality control for smooth engineering surfaces are becoming more and more important in modern science and technology due to their important engineering functions and high production costs. NIST has frequently received requests for U.S. industry to provide Standard Reference Material (SRM) high-precision, random profile roughness specimens to support smooth surface measurements ...

    SBIR Phase I 2012 Department of CommerceNational Institute of Standards and Technology
  10. High Performance Signal Processing Tools with Fluctuation-Enhanced Sensing

    SBC: Signal Processing, Inc.            Topic: 9020163R

    We propose a high performance library of signal processing tools that incorporate a newly developed technique known as fluctuation enhanced sensing (FES) to enhance the novel microsensor developed at NIST. Our goal is to improve the performance of the NIST sensor from two angles. One is to apply our existing proven algorithms to the NIST data. The other one is to incorporate advanced FES concept t ...

    SBIR Phase I 2011 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government