You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Framework for Biometric Identification on the Move

    SBC: AFIS and Biometrics Consulting Inc.            Topic: HSB072003

    We are proposing to develop a prototype system for identifying subjects on the move utilizing multiple biometrics with a very high probability of identification. The system would contain cutting edges sensors and technology. This system would also serve as a system for testing subject user interaction at collection points as well as testing any biometric or projecting the results of fused biometri ...

    SBIR Phase II 2009 Department of Homeland Security
  2. Secure and Reliable Wireless Communication for Control Systems

    SBC: TOYON RESEARCH CORPORATION            Topic: HSB072005

    Sensors and allocation elements, such as valves and actuators, are pervasive in control systems. In an effort to reduce operating costs and increase system safety, there has been significant research and development focused on wireless sensor systems. To date, there has been limited penetration of wireless technologies to control systems. Those that have been deployed often lack security features ...

    SBIR Phase II 2009 Department of Homeland Security
  3. Responder Wireless Physiological Monitoring Device

    SBC: UTOPIACOMPRESSION,CORPORATION            Topic: HSB071005

    Today's state-of-the-art Medical-Vests-Shirts are inflexible and expensive. Typically, data collection component functions as a multichannel cardiopulmonary digital-recorder with physiologic-sensors-array sewn to the shirt to monitor vital signs. The lack of flexibilityintegral- unity and cost of the current vests is a prohibiting factor in their use in first responder applications. The vests also ...

    SBIR Phase II 2009 Department of Homeland Security
  4. Annular Gas Jet Anode for Decade

    SBC: ALAMEDA APPLIED SCIENCES CORPORATION            Topic: DTRA04010

    Alameda Applied Sciences Corporation (AASC) proposes to replace the anode posts of a soft x-ray z-pinch with an azimuthally symmetric shell of high density, low atomic number gas. Once ionized, the gas column carries the current and eliminates particulate debris that is otherwise generated by the return rods. The gas shell also absorbs unwanted UV and hence eliminates the first Li foil filter of t ...

    SBIR Phase II 2006 Department of DefenseDefense Threat Reduction Agency
  5. A fast pulse, intermediate flux, bench-top, high rep-rate x-ray source for PRS diagnostic calibration

    SBC: ALAMEDA APPLIED SCIENCES CORPORATION            Topic: DTRA06013

    DTRA requires reliable X-ray sources to irradiate test objects for customers. One key component of test object irradiation is reliable radiation diagnostics to measure the dose and dose-rate to test objects. Current radiation diagnostics possess unacceptable levels of variation. Alameda Applied Sciences Corp proposes the use of a dense plasma focus device as a flat field X-ray calibration sourc ...

    SBIR Phase I 2006 Department of DefenseDefense Threat Reduction Agency
  6. Development of a 3/6/9 MeV X-ray Generator

    SBC: Accuray Incorporated            Topic: N/A

    Accuray bases this proposal on an X-ray generator, model DX500K, designed, built, and delivered to a major contractor in December 2008 as part of the DNDO-CAARS program. Accuray`s DX500K operates at single or dual energy modes of 6 MeV and 9 MeV and interleaves between 6 MeV and 9 MeV at 400 Hz. The pulse to pulse jitter is negligible -- a major performance factor in high Z detection. The system o ...

    SBIR Phase I 2009 Department of Homeland Security
  7. Interactive Neuro-Educational Technolgies (I-INET): Enhanced Training of Threat Detection

    SBC: ADVANCED BRAIN MONITORING, INC.            Topic: N/A

    According to Department of Homeland Security (DHS), over 700 million pieces of baggage are screened for potential threats in the U.S. every year. Training methods for DHS screeners rely on conventional classroom instruction and on-the-job mentoring. By definition, a screener's work is challenging because the search for threats demands sustained, focused attention while reviewing many images with v ...

    SBIR Phase I 2009 Department of Homeland Security
  8. Low-Noise Detector Arrays for Raman Spectroscopy

    SBC: Aerius Photonics, LLC.            Topic: N/A

    We propose to demonstrate near infrared (NIR) InGaAs sensor arrays with 55% lower noise than arrays presently available to improve the sensitivity of current spectroscopy systems. The low noise performance will be enabled by the use of low-noise source follower per detector ROICs, which are also used in astronomy with HgCdTe for low noise measurements. With design improvements to current available ...

    SBIR Phase I 2006 Department of CommerceNational Institute of Standards and Technology
  9. Miniature Unmanned Aerial Vehicle (MUAV)

    SBC: AEROVIRONMENT, INC.            Topic: SOCOM05011

    Special operation forces utilize C-130 aircraft that often operate in night/adverse weather, low-level, deep-penetration missions in contested or hostile environments. These low altitude missions result in higher risks to the crew and aircraft. AeroVironment proposes to leverage their current packaged and air-launched unmanned aerial vehicle (UAV) developments to design a self-contained, packaged ...

    SBIR Phase I 2006 Department of DefenseSpecial Operations Command
  10. Aerosol Collection into Small Liquid Volumes for Biological Assays

    SBC: AEROSOL DYNAMICS INC            Topic: N/A

    Detection systems for aeropathogens require the concentration of airborne particles from large volumes of air into small volumes of liquid. This proposal addresses this need through droplet encapsulation of airborne particles, with subsequent capture into a microliter-sized collection reservoir. Droplet encapsulation is accomplished through our company¿s proven, patented growth tube technology. T ...

    SBIR Phase I 2006 Department of Homeland Security
US Flag An Official Website of the United States Government