You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Low-Output High Precision Automated Powder Disseminator

    SBC: ADVANCED MECHANICAL SYSTEMS TECHNOLOGY,            Topic: CBD06101

    This proposal presents a Phase I SBIR project to develop a high precision, low disperse rate powder disseminator for the US Army. In the development of the sensitive detecting agent, we need to release a precise amount of C&B agents in the controlled detection experiments. However, such a technology does not exist at the present time. After examining existing technologies, we believe that the r ...

    SBIR Phase I 2006 Department of DefenseOffice for Chemical and Biological Defense
  2. Filovirus drug discovery using novel combinations of approved drugs

    SBC: APATH, LLC            Topic: CBD05119

    The goal of this proposal is to find novel combinations of approved drugs for the treatment and/or prevention of infection with filoviruses. Ebola and Marburg viruses, the only filoviruses, cause an acute hemorrhagic fever syndrome which has a high mortality rate and poses a significant bio-terrorism threat. There are currently no therapeutic agents available to treat filovirus infections and the ...

    SBIR Phase II 2006 Department of DefenseOffice for Chemical and Biological Defense
  3. Sensitive Molecular Beacons (MB) Based DNA Microarray

    SBC: BIOMACHINES, INC.            Topic: CBD02101

    In the wake of the September 11th attacks and subsequent Anthrax scares, researchers worldwide are working to expand our ability to rapidly assess what poses a terrorism threat to the public. The rapid detection of specific pathogens is required for biod

    SBIR Phase II 2004 Department of DefenseOffice for Chemical and Biological Defense
  4. Analysis Tools for Detection and Diagnosis of Biological Threats

    SBC: ALPHA-GAMMA TECHNOLOGIES, INC.            Topic: CBD04113

    DNA microarray technology, in combination with statistical and predictive modeling tools, could be used to evaluate thousands of genes against distinct gene expression patterns induced by chemical/biological agents to provide early identification and speed therapeutic intervention. The overall objective of this proposal is to demonstrate the feasibility of building a data management system for DN ...

    SBIR Phase I 2004 Department of DefenseOffice for Chemical and Biological Defense
  5. Hermetic Textile Closure Hardware System

    SBC: SIGMA K CORP            Topic: CBD04110

    Sigma-K Corporation proposes to develop a Hermetic Textile Closure Hardware System to be used for Chemical Biological (CB) protective clothing and Collective Protection (COLPRO) portable shelter systems. Our Hermetic Textile Closure Hardware System design will allow the user to easily don and doff one's protective apparel. The system will remain intact during combat behavior. The closure interface ...

    SBIR Phase I 2004 Department of DefenseOffice for Chemical and Biological Defense
  6. Optically clear multi-layered protective window/sensor film for use on rotary wing aircraft

    SBC: UNITED PROTECTIVE TECHNOLOGIES LLC            Topic: SOCOM04002

    Since the inception of windscreens on aircraft, the effects of erosion on the transparent materials utilized for this application has been problematic. With the development of faster aircraft, Night Vision Goggles and various sensors which utilize electromagnetic waves in the visible and IR ranges this problem has been intensified. The team at United Protective Technologies, propose to provide dat ...

    SBIR Phase I 2004 Department of DefenseSpecial Operations Command
  7. Construction of a Force Probe for Characterization of Microscale Features

    SBC: INSITUTEC, INC.            Topic: N/A

    The Phase 2 objective is to provide NIST with a modular gauge head unit equipped with InsituTec's standing wave probe technology. The complete gauge head unit will be retrofitted to the NIST M48 which is one of the most precise measuring machines in the world. This unit will enable NIST to achieve the agency's program goal in dimensional metrology which is to provide microscale measurement capacit ...

    SBIR Phase II 2006 Department of CommerceNational Institute of Standards and Technology
  8. Tool Condition Monitoring and Diagnostics

    SBC: VulcanCraft            Topic: N/A

    A smart machine tool must be able to monitor its condition and report problems. Every CNC machine should provide an alarm for tool condition problems, including tool wear, much as every automobile has a low oil indicator. Tool wear is particularly important for unattended machining as a worn tool can ruin a part. All current tool condition systems operate "blind" without direct information on curr ...

    SBIR Phase I 2003 Department of CommerceNational Institute of Standards and Technology