You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Fabrication of Advanced Waveguide Structures for Efficient Violet and Near-UV Generation

    SBC: ADVR, INC.            Topic: N/A

    This SBIR Phase I effort will establish the feasibility of fabricating advanced waveguide structures in potassium titanyl phosphate (KTP) capable of efficiently generating 25 to 40 mW of frequency converted light in the 395 to 480 nm. The key innovation in this effort is to utilize KTP waveguides in a single-pass frequency doubling device to efficiently produce the desired laser wavelengths and po ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  2. High Efficiency Up conversion Single-Photon-Detector for 1550 nm Signal

    SBC: ADVR, INC.            Topic: N/A

    This NIST Phase II SBIR effort will two low noise single photon detectors using MgO doped LiNbO3 (LN) periodically poled waveguides and a 980nm (or similar appropriate wavelength) pump to up convert 1550nm photons to 600nm to allow for detection by photomultiplier tube (PMT). The key innovation is using low noise periodically poled waveguides with a long wavelength (1800nm) pump leading to higher ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  3. Low Visibility Decoy Flare

    SBC: AERODYNE RESEARCH INC            Topic: SOCOM09002

    Low visibility flares offer significant advantages for nighttime protection of rotary wing vehicles. Aerodyne Research Inc (ARI) and its teaming partner ATK propose flares having nearly same intensity in IR bands of interest while having greatly reduced visibility. The Phase I program will build on previous work performed by ARI on low visibility flares to identify candidate flare compositions h ...

    SBIR Phase I 2009 Department of DefenseSpecial Operations Command
  4. High-Performance Opto-Electronic Oscillator for Millimeter Wave

    SBC: AGILTRON, INC.            Topic: N/A

    Leveraging Agiltron¿s recent breakthrough in the broad band and tunable photonic high-Q factor RF filtering technique, we propose to develop a high-spectral-purity, low-phase-noise, spurs-free opto-electronic oscillator (OEO) operating at W-band for the NIST applications. Based on our unique technical approach and successful development in low loss fiber optics, RF photonic components/modules, an ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  5. Integrated Self-powered MEMS-Insect Swarms for biochemical detection

    SBC: AGILTRON, INC.            Topic: CBD09105

    In this program, Agiltron proposes the development of self-powered bio-mechanical swarms for detection and communication of biochemical agents for both civil and defense applications. We propose to integrate a micro electro-mechanical suite of sensors, actuators, power harvesters and electronics by surgical insertion during early metamorphosis of insects to allow rugged and reliable biomechanical ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
  6. A Fully Integrated Commercial Multi-sample Multi-Slit Rheometer

    SBC: CAMBRIDGE POLYMER GROUP INC            Topic: N/A

    Proposed here is the continued development of an innovative rheometer configuration design at NIST. It describes the determination of suitable detection, drive, control, software and assembly designs for a commercially viable, fully integrated device. The initial efforts will concentrate on examining the sub-systems of the design. An important feature of the proposed strategy is early commercial i ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  7. Registration of EO and LIDAR using an Interoperability Architecture for Net-Centric Environments (RELIANCE)

    SBC: CHARLES RIVER ANALYTICS, INC.            Topic: SOCOM09003

    The “see first, understand first, act first, finish decisively” principle requires that military commanders and analysts be provided a complete, up-to-the-second view of the battlefield. Currently deployed full motion video (FMV) sensors provide crucial real-time situational awareness, but suffer from limited field of view and lack of geographical context. Augmenting current FMV displays with ...

    SBIR Phase I 2009 Department of DefenseSpecial Operations Command
  8. Developing Centrifugation Based Length Separation of SWCNTs for Advanced Applications

    SBC: Eikos, Inc.            Topic: N/A

    Carbon nanotubes are one of the most studied and potentially useful nanoparticles known. However, presently even the purest are only commercially available in mixtures of chiralities and lengths. Even though numerous lab scale methods to separate them have been demonstrated, few offer the potential to be scaled and offered as a product. Eikos has found that, for many applications, nanotube length ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  9. Medical Network Traffic Recorder and Real Time Diagnostic System

    SBC: IDX Group, Inc.            Topic: N/A

    The medical device market rises rapidly as innovation produces a stream of new applications. The added mobility offered by wireless telemetry is fueling a trend of wirelessly networked devices. Standard wireless interfaces like ISO/IEEE 11073 are increasingly being adopted for interoperability. This boosts the proliferation of wireless medical devices yet also generates reliability challenges due ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  10. Spectroscopic high throughput identification of protein variants

    SBC: LEXITEK INC            Topic: CBD09104

    Quantitative Raman spectroscopy offers a means of estimating concentrations of protein variants. The Raman spectrum can be a fingerprint of an individual molecule and features unique to functional groups. In conjunction with robust data analysis such as principal component analysis (PCA), chemometric assessment of a sample can be performed. As an optical technique, this approach can yield high-thr ...

    SBIR Phase I 2009 Department of DefenseOffice for Chemical and Biological Defense
US Flag An Official Website of the United States Government