You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. Development of a Rapid Monitoring System for Detection of Pathogens in Marine Aquaculture

    SBC: INNOVAPREP LLC            Topic: 836

    pathogens in marine aquaculture waters. Phase II research will look to improve sample concentration, cell lysis, and DNA purification techniques that were developed in Phase I. More specifically, optimization of the prototype lysis/elution fluid will be further developed for cell lysis using BSL-1 organisms, Vibrio harveyi, a surrogate for pathogenic Vibrio ssp. Techniques will be developed to ove ...

    SBIR Phase II 2019 Department of CommerceNational Oceanic and Atmospheric Administration
  2. Low Signature Optical Guidance of Low Collateral Munitions

    SBC: CORVID TECHNOLOGIES, LLC            Topic: SOCOM061008

    At present, there are no solutions for equipping Class 1 and 2 unmanned aerial system (UAS) platforms with weapons systems that provide the capability for opportunistic engagement of high value targets (HVT). Munitions deployed on larger UAS, and other fixed-wing SOCOM assets, greatly exceed the payload capacity of Class 1 and 2 UAS assets currently in use for intelligence, surveillance, and recon ...

    SBIR Phase II 2019 Department of DefenseSpecial Operations Command
  3. Development of a Long Term pH and pCO2 Lagrangian Drifter

    SBC: SUNBURST SENSORS, LLC            Topic: 831C

    Quantifying oceanic CO2 uptake and ocean acidification and understanding their impact on global climate and ocean ecology are key goals of NOAA’s climate change research programs. NOAA’s request for Development of a long-term Lagrangian pH and pCO2 drifter (SBIR Subtopic 8.3.1C) aims to address these goals by developing technology that measures both pCO2 and pH that can be widely deployed in t ...

    SBIR Phase II 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  4. Porous Membrane Electrode for Quantitative Detection of Toxins

    SBC: Mercury Science Inc.            Topic: 816N

    In Phase I, a novel porous electrode was designed to demonstrate a rapid, simple assay for the detection of domoic acid in marine samples. During Phase II, methods to manufacture porous electrodes will be improved to enable high volume production of low-cost biosensors that can be connected to a potentiostat. These biosensors will be incorporated into a portable test kit for the quantitation of do ...

    SBIR Phase II 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  5. Development and Prototyping of a Digital Pulse Processor for Improved Coincidence Detection, Rejection, and Pulse Recovery, for High Count-Rate Silicon Drift Detectors

    SBC: 4pi Analysis, Inc.            Topic: N/A

    The recent emergence of the Silicon Drift detector (SDD), for use in energy dispersive x-ray spectrometry (EDS), has made possible x-ray event streams with count rates as high as 1-10 Mcps. A problem with existing digital signal processing, as applied to SDDs, is the significant presence of coincidence peaks above the x-ray background. These coincidence peaks occur with amplitudes comparable to lo ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  6. High Efficiency Up conversion Single-Photon-Detector for 1550 nm Signal

    SBC: ADVR, INC.            Topic: N/A

    This NIST Phase II SBIR effort will two low noise single photon detectors using MgO doped LiNbO3 (LN) periodically poled waveguides and a 980nm (or similar appropriate wavelength) pump to up convert 1550nm photons to 600nm to allow for detection by photomultiplier tube (PMT). The key innovation is using low noise periodically poled waveguides with a long wavelength (1800nm) pump leading to higher ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
  7. Efficient Low-Dark-Count Detector for Photon Counting

    SBC: VOXTEL, INC.            Topic: N/A

    Voxtel has demonstrated efficient high-speed photon counting with thresholded linear-mode avalanche photodiode (APD) receivers using multi-gain-stage InGaAs/InAIAs APDs. In contrast to Geiger APDs, thresholded photon-counting linear APD receivers are thought not to suffer afterpulsing, and can support maximum count rates (MCR) up to 2 or 3 orders of magnitude faster than Geiger APDs. However, the ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government