  1. Query-Based Interoperability for Simulation of Composite Structures

    SBC: INTACT SOLUTIONS, INC            Topic: 9020673R

    We propose to design and implement a query-based approach to interoperable modeling and simulation of composite material structures, that usually contain the manufacturing recipe within their design. In Phase I, we established the feasibility of the approach using a demonstration scenario of CAD/CAE interoperability for assemblies. In Phase II, we propose to develop a series of use-case scenarios ...

    SBIR Phase II 2013 Department of CommerceNational Institute of Standards and Technology
  2. Bragg Grating Enhanced Narrowband Single Photon SPDC Source

    SBC: Gener8, LLC            Topic: 9010177TT

    Spontaneous Parametric Down conversion (SPDC) is currently an active research area in quantum communications (QC) to develop entangled single photon sources. However, the bandwidth of current SPDC sources is too broad for many applications. NIST researchers have modeled a solution to this problem that reduces the bandwidth by >50. We proposed to fabricate a prototype of the NIST device by developi ...

    SBIR Phase I 2013 Department of CommerceNational Institute of Standards and Technology
  3. High Speed Imaging Spectropolarimeter for Dynamic Samples

    SBC: POLARIS SENSOR TECHNOLOGIES INC            Topic: 9020663R

    Spectroscopic ellipsometry is recognized as the gold standard in noncontact characterization of the refractive index and thickness of a thin optical film or film stack on a substrate. However, it suffers from a number of shortcomings, perhaps the most important of which is the time required to perform a single measurement. Moreover, manufacturers are interested in comprehensive evaluation of thin ...

    SBIR Phase I 2013 Department of CommerceNational Institute of Standards and Technology
  4. Digital Micromirror Device Detection Scheme for Transmission Scanning Electron Microscopy

    SBC: RADIABEAM TECHNOLOGIES, LLC            Topic: N/A

    Accurate quantitative characterization of materials is crucial for a wide range of industrial and research applications. New transmission scanning electron microscopy (t-SEM) methods have the potential for high-resolution imaging similar to transmission electron microscopy (TEM) with a less expensive, faster, and more widely available SEM system. To exploit the full potential of these imaging tech ...

    SBIR Phase I 2013 Department of CommerceNational Institute of Standards and Technology
  5. : Advanced Tactile Sensing for Dexterous Robot Hands in Industrial Automation and Assembly

    SBC: Syntouch L.L.C.            Topic: 9020173R

    Robotic actuators exceed human speed, accuracy, and strength, but human hands are regarded as the ultimate in dexterity. SynTouch proposes this is due absent human-like tactile sensing and intelligent reflexive behaviors in robots. SynTouch created a multimodal compliant tactile sensor that mimics the sensory ability of the human fingertip (force, vibration and temperature) and algorithms that fil ...

    SBIR Phase I 2013 Department of CommerceNational Institute of Standards and Technology
  6. C-Care: An automated combat casualty diagnostic and monitoring system

    SBC: UTOPIACOMPRESSION,CORPORATION            Topic: SOCOM13003

    UtopiaCompression and team put forth a novel solution for medical diagnostics and continuous monitoring of combat casualties in the battlefield to improve survivability while reducing cost to the military. We propose advances in both physiological diagnostic intelligence and associated physiological sensors systems for a complete solution. The system will consist of the state of the art physiologi ...

    SBIR Phase I 2013 Department of DefenseSpecial Operations Command
  7. Family of Sub-Sonic Ammunition

    SBC: Southwest Services LLC            Topic: SOCOM13005

    This program will consist of a three prong approach to provide an unbiased assessment and development of subsonic ammunition with the highest success rate balanced against technological advancement. Our feasibility study will include: 1) A brass case utilizing a polymer insert to optimize subsonic interior ballistics, 2) A lightweight low cost aluminum cartridge case utilizing a polymer insert, ...

    SBIR Phase I 2013 Department of DefenseSpecial Operations Command
  8. High-Performance Arbitrated Logic Processing Topology

    SBC: Physical Optics Corporation            Topic: SOCOM13007

    To address the SOCOM need for field-operable computing"bricks", Physical Optics Corporation (POC) proposes to develop High-performance Arbitrated LOgic processing Topology (HARLOT) device. HARLOT is a computing brick housed in a man-portable, ruggedized package designed for field use and offers>16 Terabyte non-volatile memory and>1 TeraFLOPS computational capability while consuming

    SBIR Phase I 2013 Department of DefenseSpecial Operations Command
  9. An Advanced Algorithm for Radar Derived Bathymetry

    SBC: Arete Associates            Topic: 913N

    NOAA can reduce costs and improve efficiency by remotely monitoring harbors, navigation channels, and coastlines for bathymetric changes. This will aid NOAA in its mission to maintain waterways and assure maritime safety. This remote sensing can be accomplished by implementing a new radar derived bathymetry capability. Areté Associates proposes to demonstrate an advanced algorithm to derive ba ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  10. Dynamic Frequency Passive Millimeter-Wave Radiometer Based on Optical Up-Conversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: 941D

    In the proposed effort, we will leverage this extensive experience and capabilities to realize a frequency agile mmW radiometer that can cover the range of DC-110 GHz and can be scaled to DC-200 GHz under Phase II. Ours is a photonic system that multiplies and up-coverts a low-frequency reference signal onto an optical carrier (laser) using EO modulation, then uses the modulation sidebands to inj ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration