You are here

Award Data

For best search results, use the search terms first and then apply the filters
Reset

The Award database is continually updated throughout the year. As a result, data for FY24 is not expected to be complete until March, 2025.

Download all SBIR.gov award data either with award abstracts (290MB) or without award abstracts (65MB). A data dictionary and additional information is located on the Data Resource Page. Files are refreshed monthly.

The SBIR.gov award data files now contain the required fields to calculate award timeliness for individual awards or for an agency or branch. Additional information on calculating award timeliness is available on the Data Resource Page.

  1. WS-BD Conformant Handheld Multi-biometric Acquisition System

    SBC: Fulcrum Biometrics, LLC            Topic: 9010477TT

    Secure trusted biometric validation of identity has never been more important. The increase in global terrorism, unfettered identity theft and new legislation requiring multi-factor authentication are a few of the driving factors. The biometrics industry has not actively responded to the changing market conditions being driven by the explosion in mobile computing. Millions of new mobile devices ar ...

    SBIR Phase II 2013 Department of CommerceNational Institute of Standards and Technology
  2. Development of a Long Term pH and pCO2 Lagrangian Drifter

    SBC: SUNBURST SENSORS, LLC            Topic: 831C

    Quantifying oceanic CO2 uptake and ocean acidification and understanding their impact on global climate and ocean ecology are key goals of NOAA’s climate change research programs. NOAA’s request for Development of a long-term Lagrangian pH and pCO2 drifter (SBIR Subtopic 8.3.1C) aims to address these goals by developing technology that measures both pCO2 and pH that can be widely deployed in t ...

    SBIR Phase II 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  3. Secure Mobile Platform

    SBC: CROSSFIELD TECHNOLOGY LLC            Topic: SOCOM13007

    Crossfield Technology LLC proposes the design and development of an Accelerated Processing Unit (APU) System on Chip (SoC) consisting of a hybrid CPU/GPU digital signal processor. The APU incorporates high-speed interfaces to external sensors and a NAND Flash Controller. The NAND Flash Controller implements XTS-AES-256 encryption commonly used for whole disk encryption, and can securely erase the ...

    SBIR Phase I 2013 Department of DefenseSpecial Operations Command
  4. Dynamic Frequency Passive Millimeter-Wave Radiometer Based on Optical Up-Conversion

    SBC: PHASE SENSITIVE INNOVATIONS INC            Topic: 941D

    In the proposed effort, we will leverage this extensive experience and capabilities to realize a frequency agile mmW radiometer that can cover the range of DC-110 GHz and can be scaled to DC-200 GHz under Phase II. Ours is a photonic system that multiplies and up-coverts a low-frequency reference signal onto an optical carrier (laser) using EO modulation, then uses the modulation sidebands to inj ...

    SBIR Phase I 2013 Department of CommerceNational Oceanic and Atmospheric Administration
  5. Protective Superhydrophobic Coatings for Underwater Electronics

    SBC: LYNNTECH INC.            Topic: SOCOM13001

    Sensitive and expensive electronic equipment used in marine environments are generally subjected to harsh extremes. Component lifetimes are typically extended by physical isolation using bags, hard containers or with conformal impermeable coatings. However, over time, protective measures become compromised, the resulting exposure causing corrosion and short circuit-driven malfunctions. There is ...

    SBIR Phase I 2013 Department of DefenseSpecial Operations Command
  6. Miniature Netted Sensors

    SBC: WILLIAMSRDM, INC.            Topic: SOCOM06015

    Williams-Pyro is developing an AccuTag Miniature Surveillance and Tracking System (Accu-MiSTS). Accu-MiSTS employs cluster management techniques and ad-hoc networking to provide a readily scalable architecture with which to perform comprehensive surveillance. A cluster comprises one supernode and up to 65,536 nodes, all of which are within the communication range of at least one other node. The Ac ...

    SBIR Phase II 2008 Department of DefenseSpecial Operations Command
  7. Deep Submergence Rated Flexible Hoses and Piping System Connectors

    SBC: MEI-CHARLTON, INC.            Topic: SOCOM08002

    The objective of this proposal is to demonstrate the feasibility of developing flex hoses for hydraulic and other piping system interfaces that can withstand high pressure environments, hydrodynamic, and other forces unique to deep submergence system operating environments. This hose and connecter system coined FlexiHOSE© proposed by MEI-Charlton, Inc. (MEIC) will meet the need of operating under ...

    SBIR Phase I 2008 Department of DefenseSpecial Operations Command
  8. High Efficiency Single Photon Up-Conversion in Waveguides and Pump Wavelength Longer than the Signal Wavelength

    SBC: ADVR, INC.            Topic: N/A

    This NIST Phase 1 SBIR effort will demonstrate the feasibility of low noise single photon up conversion using KTiOPO4 (KTP) or LiNbO3 (LN) or Stoichiometric LiTaO3 (SLT) periodically poled waveguides and an 1800nm pump for a high efficiency single photon detector. The key innovation is using low noise periodically poled waveguides with a long wavelength (1800nm) pump leading to higher efficiency s ...

    SBIR Phase I 2008 Department of CommerceNational Institute of Standards and Technology
  9. Fabrication of Advanced Waveguide Structures for Efficient Violet and Near-UV Generation

    SBC: ADVR, INC.            Topic: N/A

    This SBIR Phase I effort will establish the feasibility of fabricating advanced waveguide structures in potassium titanyl phosphate (KTP) capable of efficiently generating 25 to 40 mW of frequency converted light in the 395 to 480 nm. The key innovation in this effort is to utilize KTP waveguides in a single-pass frequency doubling device to efficiently produce the desired laser wavelengths and po ...

    SBIR Phase I 2009 Department of CommerceNational Institute of Standards and Technology
  10. High Efficiency Up conversion Single-Photon-Detector for 1550 nm Signal

    SBC: ADVR, INC.            Topic: N/A

    This NIST Phase II SBIR effort will two low noise single photon detectors using MgO doped LiNbO3 (LN) periodically poled waveguides and a 980nm (or similar appropriate wavelength) pump to up convert 1550nm photons to 600nm to allow for detection by photomultiplier tube (PMT). The key innovation is using low noise periodically poled waveguides with a long wavelength (1800nm) pump leading to higher ...

    SBIR Phase II 2009 Department of CommerceNational Institute of Standards and Technology
US Flag An Official Website of the United States Government